background image

Product Summary

The Indoor MotionViewer DCV601 is a wireless, indoor  
motion activated camera designed for use with  
Videofied security systems. The camera includes the fol-
lowing features:

Lithium batteries for long life.

>

  Wide angle lens.

>

  Infrared LED for night illumination.

>

  Standard motion coverage lens (30 ft./9 m distance).

>

  Dual tamper function provides detection of both  

  wall and cover tamper.

>

  Transmits check-in/status signal every 8 minutes.

Installation Guidelines

For easier installation, programming and RF testing  
should be done to check for good communication between 
the control panel and all system devices before mounting 
system devices. 

Install the detector and other system devices in the order 
of the following steps:

>

  Programming/RF Testing - program detector and all other    

  devices into the control panel and test RF communication from  
  each intended device location to the control panel.

>

  Mounting - mount detector at the tested location.

Programming/RF Testing

The following provides summarized steps for device  
programming and testing. For complete details, refer    
to the control panel installation manual. 

1

  Loosen bottom screw, separate base   

 

 

from camera and install batteries.

2

  Re-attach base to secure  

 

tamper switch.

3

  Put control panel into  

 

programming/configuration mode.

4

  Using a programmed alphanumeric 

 

keypad, proceed through menus  

 

until the display shows ADD A  

 

NEW DEVICE.

5

 Press 

Yes.

 The display shows PRESS    

 

 

PROGRAM BUTTON OF DEVICE.

6

  Press and release program button  

 

on camera using a paper clip end.  

 

The camera LED flashes. Wait for  

 

keypad display to show CAMERA 

 

(1 - 25) PROGRAMMED.

 Press 

Yes.

 The display shows 

 

RADIO RANGE TEST? Press 

Yes

    

 

again. The camera LED starts  

 

flashing and keypad display  

 

shows TEST IN PROGRESS. 

8

  Take camera to its intended mounting location and  

 

make sure LED flashes continuously or you receive a 5/5   

 

or 9/9 indicating good communication with the control    

 panel.

9

 Press 

YES

 to end radio range test, then press 

Esc/No.

10

  The display shows AREA ALLOCATION AREA: 1. Press 

 

either arrow button repeatedly until desired AREA  

 

 

number appears, then press 

Yes.

11

  The display shows NAME + LOCATION. Enter appropriate 

 

device name/location (up to 16 characters), then press    

 

Yes.

 The display shows the device number and name  

 

 

for your verification.

12

 Press 

Yes.

 The display shows FUNCTIONAL DEVICE  

 

 

TEST? Press 

Yes

 again and verify camera operation.  

 

For example, wave your hand in front of the sensor to  

 

 

activate its LED indicating detection. (walk test LED)

13

 Press 

Yes

 to end detection verification.

14

  The display shows ADD A NEW DEVICE?  

 

Repeat steps 1 – 14 for remaining cameras. 

15

  When finished, exit from configuration mode. 

www.videofied.com

Program Button

Screw

P R O D U C T   I N S T A L L A T I O N   S H E E T

Indoor MotionViewer DCV601

Made by RSI VIDEO TECHNOLOGIES

2220-IMVIS March 2012

Summary of Contents for DCV601

Page 1: ...alphanumeric keypad proceed through menus until the display shows ADD A NEW DEVICE 5 Press Yes The display shows PRESS PROGRAM BUTTON OF DEVICE 6 Press and release program button on camera using a paper clip end The camera LED flashes Wait for keypad display to show CAMERA 1 25 PROGRAMMED 7 Press Yes The display shows RADIO RANGE TEST Press Yes again The camera LED starts flashing and keypad displ...

Page 2: ... such as curtains fans or animals 1 Separate base from camera 2 Hold camera base against mounting surface and mark the two appropriate mounting holes 3 Drill pilot holes and install anchors where needed 4 Place base on mounting surface so holes line up with pilot holes anchors and secure base with appropriate screws 5 Install batteries into camera observing correct polarity 6 Attach camera to base...

Page 3: ...on 5 frames s for 10 seconds Night illumination 2 infrared LEDs Night illumination switching Automatic Night illumination distance UP to 14 ft 4 5 m Motion detector technology Passive infrared DSP Motion detector type Dual element Motion Lens Fresnel Motion Detection angle 85 Motion Detection distance Up to 40 ft 12 m Motion Detection pattern 24 facets Operating temperature 14 104 F 10 40 C Maximu...

Page 4: ...at interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and recei...

Reviews: