iBT100 12 Volt Automotive Battery Analyzer User’s Guide - English Version_V2.00
9
d. No Volt Output. No generator volt output is detected. Check the generator connection cable,
the drive belt of generator and engine whether normal or not.
e. Diode Test: Through the test of charging current ripple, tester will find out whether the diode
is normal or not. When ripple volt is too high, it proves at least one diode is damaged. Check and
replace the diode.
2.5 View test result
After choose “
Review Data
” and press
OK
button you can view the final test result.
3 Language
Language menu lets you choose system language. The device is set to English menu by default.
To change the language setting:
1.
Choose
LANGUAGE
from main menu.
2.
Use the
UP
or
DOWN
button to select the language you need and press the
OK
button to
confirm and return.