![Videcon Concept Pro VHSD-810EXT User Manual Download Page 5](http://html1.mh-extra.com/html/videcon/concept-pro-vhsd-810ext/concept-pro-vhsd-810ext_user-manual_1015192005.webp)
DIP Switch Setup
DIP Switch Setup
2
8
9
Choose the appropriate baud rate protocol by setting the DIP switch
Choose the termination resistor on/off to notify the last camera.
ON
2
1
3 4
5 6 7
8
ON
2
1
3 4
5 6 7
8
ON
2
1
3 4
5 6 7
8
ON
2
1
3 4
5 6 7
8
2400 BPS
1
4800 BPS
2
9600 BPS
3
19200 BPS
4
ON
2
1
3 4
5 6 7
8
38400 BPS
5
ON
2
1
3 4 5 6 7
8
Normal
1
ON
2
1
3 4 5 6 7
8
Last Camera
2
Camera ID Setup
- ID number of camera is set using binary number. The example is shown below.
Pin
1
2
3
4
5
6
7
8
1
2
4
8
16
32
64
128
ID Value
ex) ID=5
on
off
on
off
off
off
off
off
off
on
off
on
off
off
off
off
ex) ID=10
- Select the appropriate baud rate with DIP switch
combination.
- The factory default is 2400BPS.
3. Baud Rate Setup
- If you want to control a certain camera, you must
match the camera ID with ‘CAM ID’, setting of DVR
or keyboard controller.
- ID number of the camera is set using binary number.
- The range of ID is 0~255. Factory default of
camera ID is 1.
- Camera ID will be effective without rebooting
the camera.
5. DIP Switch for Camera ID Setup
- Pin 8 is use for on/off of RS-485 termination.
Normally, it must be off state.
- Especially, when you have trouble with long daisy
chain style connection, turn on this termination
switch of the last camera.
4. RS-485 Termination Setup
Auto Protocol
1
Communication
Protocol Setup Pin
Baud Rate Setup Pin
RS-485 Termination
Setup Pin
Auto Protocol
1
- If you set the protocol as auto protocol the camera will
automatically recognize the kind of protocol.
(within the available protocols opposite)
Pin On/Off
If the pin is located ‘ON’ side of the printed
label, it means on. In reverse, means off.
Pin On
Pin Off
Before installing the camera, you should
set the DIP switch to configure the camera
ID, communication protocol.
Choose the appropriate communication protocol by setting the DIP switch.
ON
2
1
3 4 5 6 7 8
ON
2
1
3 4
5 6 7 8
PELCO-D
2
ON
2
1
3 4
5 6 7 8
PELCO-P
3
ON
2
1
3 4
5 6 7 8
SAMSUNG
4
ON
2
1
3 4
5 6 7 8
Bottom of Main Body
ON
1
ON
1
If there is other combination of pins from above, it will be recognize as
auto protocol.
ON
2
1
3 4 5 6 7 8
ON
8J
2
1
3
4
5
6
7
8
DIP Switch for
Communication
DIP Switch for
Camera ID Setup
AD
(American Dynamics)
7
ON
2
1
3 4
5 6 7 8
- It is consist of communication protocol, baud rate
and RS-485 termination setup pins.
- If you change the camera protocol by changing
the DIP switch, the change will be effective after
rebooting the camera.
1. DIP Switch for Communication
- If you want to control using DVR or keyboard
controller, their protocol must be identical to the
camera’s protocol. Otherwise, you cannot control
the camera.
- The factory default is PELCO-D protocol.
2. Communication Protocol Setup
2. Communication Protocol Setup
Panasonic
5
ON
2
1
3 4
5 6 7 8
GE
(Kalatel)
6
ON
2
1
3 4
5 6 7 8