![Victron energy SmartSolar MPPT 150/100 Series Manual Download Page 12](http://html.mh-extra.com/html/victron-energy/smartsolar-mppt-150-100-series/smartsolar-mppt-150-100-series_manual_1014743012.webp)
11
EN
Scrolling text
Icons
Segments
Units Function or parameter
-
Relay minimum closed time
(minutes)
.
-
.
-
.
.
°C mV Battery temperature
compensation per cell (2)
,
h
Bulk time protection
.
-
.
-
.
h
Absorption time
.
.
A
Charge current below 5°C
,
BMS Present (6)
Load operation mode (7)
Load user defined low voltage
Load user defined high voltage
-
Backlight intensity
,
,
Backlight automatic turn off after
60s (8)
-
-
Text scroll speed
VE.Direct port RX pin mode (9)
VE.Direct port TX pin mode (10)
-
VE.Direct device instance
.
Software version
Reset to default settings (11)
History data reset (12)
,
Lock settings
,
Temperature unit °C/°F
Notes:
1) The factory defined battery type can be selected with the rotary switch
next to VE.Direct connector. The selected type will be shown here. The
setting can alter between a factory defined type and "USER".
2) These values can ONLY be changed for the battery type "USER". The
values in the table are for a 24V-battery.
3) Automatic equalisation can be set to “OFF” (default) or a number
between 1 (every day) and 250 (once every 250 days). See section 3.7 for
more details about automatic equalisation.
4) To allow the charger to equalise the battery properly, use the manual
equalise option only during absorbtion and float periods, and when there is
sufficient sunlight. Press SELECT: the text “
” will blink, press
SELECT again to start equalisation. To terminate the equalisation mode
prematurely, enter the setup menu and navigate to setup item 10, press
SELECT: the text “
” will blink, press SELECT again to stop
equalisation. The manual equalise duration is 1 hour.
5) This item configures the relay behaviour (setup item 11)
Value
Description
0
Relay always off
1
Panel voltage high (setup items 17 and 18)
2
Temperature high (>85C)
3
Battery voltage too low (setup items 12 and 13, default)
4
Equalization active
5
Error condition present
6
Temperate low (<-20C)
7
Battery voltage too high (setup items 14 and 15)
8
Charger in float or storage