Voltage ripple
: max. 10 % V
RMS
of nominal DC input
voltage.
Nominal input current:
Phoenix 12/300
: 30 A at 12V/300W
Phoenix 12/500
: 52 A at 12V/500W
Phoenix 24/500
: 25 A at 24V/500W
Phoenix 24/900
: 44 A at 24V/900W
Maximum input current:
Phoenix 12/300
: 185 A
Phoenix 12/500
: 185 A
Phoenix 24/500
: 90 A
Phoenix 24/900
: 170 A
Power consumption:
No-load in ‘ON’ mode:
The 12V version
: 8,5 W
The 24V version
: 10,6 W
No-load in ‘economy’ mode:
All four types
: 2,5 W
7.2 O
UTPUT
Output voltage
: 230 V
AC
+/- 1%
Output voltage range
: 185 V
AC
– 245 V
AC
Frequency
: 50 Hz +/- 0.2% (crystal controlled)
Waveform output voltage
: sine wave
Total harmonic distortion
: max. 2,5%
Powerfactor (cos phi)
: 0,2 capacitive to 0,4 inductive
Nominal power:
Phoenix 12/300
: 300 W
Phoenix 12/500
: 500 W
Phoenix 24/500
: 500 W
Phoenix 24/900
: 900 W
(cos phi = 1,0) 0ºC / +40ºC
At higher ambient temperatures the
power is re-adjusted automatically.
Temporary max. power
at 40ºC ambient temperature:
Short
term
Surge
Phoenix 12/300
: 400 W
1300 W
Phoenix 12/500
: 650 W
1350 W
Phoenix 24/500
: 750 W
140 W
Phoenix 24/900
: 1000 W
2500 W
Summary of Contents for Phoenix 12/300
Page 1: ...USER MANUAL GEBRUIKSAANWIJZING Phoenix 12 300 Phoenix 12 500 Phoenix 24 500 Phoenix 24 900 ...
Page 2: ......
Page 3: ...manual 3 SECTIONS page English 7 Nederlands 37 ...
Page 4: ...4 manual ...
Page 5: ...manual 5 USER MANUAL Phoenix 12 300 Phoenix 12 500 Phoenix 24 500 Phoenix 24 900 ...
Page 6: ...6 manual ...
Page 33: ...manual 33 8 1 DIMENSIONS ...