16
with 0.0A so that errors are eliminated. A setting of
0.0
disables this Function.
Default : 0.0A
Range : 0.0 – 2.0A
Stepsize : 0.1A
F15 : Reserved.
Default : ---
F16 : Voltage prescaler. This Function is only important when an
optional prescaler is installed in the battery voltage sense
input of the BMV-501. The voltage-charged-parameter,
undervoltage- and overvoltage alarm settings are linked with
this Function. Don’t change this value if you are not using a
prescaler!
Default : 1-1
Range : 1-1 / 1-5 / 1-10
F17 : Display (backlight) mode. Duration of backlight activation in
seconds after pressing a key on the BMV-501. Furthermore
settings can be made to leave the backlight always
ON
or
always
OFF
. In the setting
AU
the backlight will be activated
automatically when the charge/discharge current exceeds 1A
or when a key is pressed.
Default : 30 seconds
Range : OFF / 10 – 60 / ON / AU
Stepsize : 10 seconds
F18 : Reserved.
Default : ---
F19 : Firmware version. Displays the firmware version of the BMV-
501. No alterations can be made.
Default : 1.00
F20 : Setup lock. When this Function is
ON
, all functions (except
this one) are locked and can’t be altered.
Default : OFF
Range : OFF / ON
When all the necessary changes are made and double checked in the
setup-mode, it is time to jump back to the normal operating mode by
pressing the SETUP key for three seconds. Your BMV-501 is now ready
for use!