4. Specifications
Smart BMS 12-200
Alternator port - maximum charge current
100A (with a 125A fuse)
port - max charge and discharge current
200A
Peak discharge current
400A
Input voltage to start charging
>13V
Current consumption, remote on
17.5mA (excluding Load output and Charge output current)
Current consumption, remote off
6.5mA (BMS functionality still active)
4.5mA (BMS functionality disabled)
Load disconnect output
Normally high (Vbat – 0.1V)
Source current limit: 10mA (short circuit protected)
Sink current: 0A (output free floating)
Charge disconnect output
Normally high (Vbat – 0.1V)
Source current limit: 10mA (short circuit protected)
Sink current: 0A (output free floating)
Pre-alarm output
Normally low
High (Vbat) in case of alarm, max. 1A
(not short circuit proof)
Remote (or System) on/off:
Remote L and Remote H
Use modes:
1.
ON when the L and H terminal are interconnected
2.
ON when the L terminal is pulled to battery minus (V < 5V)
3.
ON when the H terminal is high (V > 3V)
4.
OFF in all other conditions
GENERAL
Operating temperature range
-40°C to +60°C
Humidity, maximum / average
100% / 95%
Protection, electronics
IP65
DC power connection
M8
Mounting torque
10Nm
DC connector battery minus
Faston female, 6.3mm
ENCLOSURE
Weight
2kg
Dimensions (hxwxd)
65 x 120 x 340 mm
STANDARDS
Emission
EN 61000-6-3, EN 55014-1
Immunity
EN 61000-6-2, EN 61000-6-1, EN 55014-2
Automotive Directive
ECE R10-5
Smart BMS 12-200
Page 10
Specifications