11
EN
NL
FR
DE
ES
SE
Appe
ndi
x
5. Specifications
BlueSolar charge controller
MPPT 150/45
MPPT 150/60
MPPT
150/70
Battery voltage
12/24/48 V Auto Select (36 V: manual)
Maximum battery current
45 A
60 A
70 A
Maximum PV power, 12V 1a,b)
650 W
860 W
1000 W
Maximum PV power, 24V 1a,b)
1300 W
1720 W
2000 W
Maximum PV power, 48V 1a,b)
2600 W
3440 W
4000 W
Maximum PV open circuit voltage
150 V
Peak efficiency
98 %
Self consumption
Less than 35 mA @ 12 V / 20 mA @ 48 V
Charge voltage 'absorption'
Default setting: 14,4 V / 28,8 V / 57,6 V
(adjustable)
Charge voltage 'equalization'
Default setting: 16,2 V / 32,4 V / 64,8 V
(adjustable)
Charge voltage 'float'
Default setting: 13,8 V / 27,6 V / 55,2 V
(adjustable)
Charge algorithm
multi-stage adaptive
(eight preprogrammed algorithms)
T emperature compensation
-16 mV/°C / -32 mV/°C / -64 mV/°C
Protection
Battery reverse polarity (fuse, not user accessible)
Output short circuit / Over temperature
Operating temperature
-30 to +60°C (full rated output up to 40°C)
Humidity
95 %, non-condensing
Maximum altitude
2000m
Environmental condition
Indoor, unconditioned
Pollution degree
PD3
Data communication port and
remote on/off
VE.Direct
See the data communication white paper on our website
Synchronized parallel operation
Not possible
ENCLOSURE
Colour
Blue (RAL 5012)
PV terminals 2)
35 mm² / AWG2 (T r models),
or dual MC4 connectors (MC4 models)
Battery terminals
35 mm² / AWG2
Protection category
IP43 (electronic components)
IP 22 (connection area)
Weight
3 kg
Dimensions (h x w x d)
200 x 250 x 95 mm
ST ANDARDS
Safety
EN/IEC 62109
1a) If more PV power is connected, the controller will limit input power to the maximum power.
1b) PV voltage must exceed Vbat + 5V for the controller to start.
T hereafter minimum PV voltage is Vbat + 1V.
2) MC4 models: several splitter pairs will be needed to parallel the strings of solar panels