6.4.1 Special display feature 

When you have an extended VE.Bus system (or a Quattro system) and you use more than 1 
AC input you might come across the following situation: 
 
Assuming you use two AC inputs. You would like to give the generator priority over the shore 
so you connect the generator to AC input 1. You do not want the user to adapt the current limit 
set point of the generator so in VEConfigure2 you uncheck the ‘overruled by remote’ checkbox 
for the current limit setting for AC input 1. 
You connect the shore current to AC input 2. For AC Input 2 you leave the ‘overruled by 
remote’ checkbox checked. 
 
The DMC will then behave as follows: 
If the generator is selected the DMC displays 

When the generator is switched off and shore current is applied, the DMC will display the set 
point for AC input 2 alternating with the AC input identification 

 
This alternating might not be what you want or expect. There is only one current limit set point 
that the user can change! When the other AC input is selected the display will always display 

. It would be sufficient to display the current limit value when AC input 2 is selected 

because that is enough indication for the operator that the system has switched to shore 
current. 
 
To achieve this, all but one of the “Upper Shore limits” must be programmed to zero. 
So in this example the limits for AC1, AC3 and AC4 must be programmed to zero. The display 
will then not alternate between 

 and the set point for AC2. 

 
Summary: Setting all but one of the “Upper Shore limits” to zero will stop the alternating of the 
display. 
 

6.5 Configuration examples 

 
Two examples are given to help you understand the setting of the parameters. 
 

Example 1: 

Two VE.Bus Multis 16A/230V + 4kVA gen. (3000 rpm) + external transfer switch. 

 
Because this is a VE.Bus system the scaling factor does not need to be set. 
A 4kVA generator can supply a maximum current of 17,4A. Using the 70% safety margin we will 
set the generator current to 12A. To set the configuration, do the following: 
1) Press and hold the configuration button until the bottom LED

 

in the left column starts flashing. 

This means you entered the configuration mode and you can change the scaling factor. As said 
this parameter can be ignored in case of VE.Bus Multis. 
2) Press the button to go to the next setting. The lower left LED will turn on indicating that the 
generator current can be set. 
3) Turn on the knob until the display indicates 12. 
4) Press the button to advance to the “Upper Shore limit for AC input 1” setting. 
5) If you want the maximum shore current the operator can set to be lower than 32 Amps you can 
change this value. 
6) Since the next 3 parameters (Upper Shore limit for AC input 2, 3 and 4) need not to be 
configured you can press the button 4 times to step through the settings and finalize the 
configuration. 
 

Summary of Contents for 8719076024354

Page 1: ...Manual EN Handleiding NL Manuel FR Anleitung DE Manual ES Appendix Digital Multi Control Panel ...

Page 2: ... PRODUCTS AND MAKES SUCH VICTRON ENERGY PRODUCTS AVAILABLE SOLELY ON AN AS IS BASIS IN NO EVENT SHALL VICTRON ENERGY B V BE LIABLE TO ANYONE FOR SPECIAL COLLATERAL INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH OR ARISING OUT OF PURCHASE OR USE OF THESE VICTRON ENERGY PRODUCTS THE SOLE AND EXCLUSIVE LIABILITY TO VICTRON ENERGY B V REGARDLESS OF THE FORM OF ACTION SHALL NOT EXCEED THE PURCH...

Page 3: ...ications Please find your application in the table below and jump to the appropriate paragraph For a more generic description of this panel please refer to chapter 3 To setup a Refer to paragraph VE Bus system with 1 AC source 2 1 VE Bus system with 2 AC sources 2 2 Extended VE Bus system with Multis 2 2 1 VE Bus system build with Quattro s 2 2 2 VE Bus Multi system external transfer switch PowerM...

Page 4: ...t can be overruled by the remote panel 2 2 2 VE Bus system built with Quattro s If your system is build with one or more Quattro s the installation of the DMC is straight forward Just connect the DMC to the VE Bus system see paragraph 4 1 and the DMC will automatically adapt to the current system Most likely you do not need to change any settings in the DMC In a Quattro the AC1 input has always pr...

Page 5: ...is when the terminals are short circuited Please change the Generator current limit parameter as needed Refer to chapter 6 for a description of how to do this If you want to limit the maximum current the operator can set you can change the Upper shore limit for AC input 1 parameter Refer to chapter 6 for a description of how to do this 2 3 Non VE Bus system with 1 AC source The DMC must be scaled ...

Page 6: ...ternal transfer switch 3 2 Connecting VE Bus devices Using the DMC with VE Bus devices is straightforward Just connect the DMC to the system The maximum minimum shore currents which can be set are automatically adapted to the system This means that Connecting the DMC to one Multi with 16A feed through capacity will limit the maximum shore setting to 16A Connecting the DMC to five of these Multis i...

Page 7: ...onfigure a scaling parameter to match the DMC with the connected system The default setting is for a standalone Multi with a 16A transfer switch There will be no adjustment for the minimum shore current limit in this case If needed an upper limit can be set to prevent the user from setting a too high limit See section 6 4 ...

Page 8: ...mation 3 There are no special requirements to build in the Digital Multi Control Panel 4 1 Bus cable To connect the DMC to a Multi or Quattro use a standard straight UTP cable with RJ45 connectors Note In case of a non VE Bus parallel system connect the DMC to the master Multi 4 2 Transfer switch wiring Only when an external transfer switch is used one has to connect a switch to the screw connecto...

Page 9: ...3Amp per device Setting a lower limit than this minimum will result in the minimum limit This is normal Multi Quattro behavior There is a feature in the Multi Quattro that when PowerAssist is enabled and the shore current setting from the remote panel is zero amps the internal transfer relay is opened and the device starts inverting VE Bus only The DMC will not allow you to set a limit lower than ...

Page 10: ... your comfort the brightness of the LEDs is controlled automatically using a light sensor When the ambient light level becomes lower the LEDs will be less bright which is more pleasant for the eye and reduces power consumption ...

Page 11: ...ble below LED indication Selected parameter Scaling factor default 0 range 0 9 this parameter is ignored when using VE Bus devices Generator current limit in Amps default 16 range 0 198 Upper shore limit for AC input 1 in Amps default 254 range 0 254 Upper shore limit for AC input 2 in Amps default 254 range 0 254 Upper shore limit for AC input 3 in Amps default 254 range 0 254 Upper shore limit f...

Page 12: ...tor current limit This parameter needs only to be configured when using an external transfer switch PowerMan see paragraph 3 1 and is of no influence otherwise The generator current limit can be set from 0 to 198 Amps in steps of 2 Amps Important note Small 3000 rpm generator sets of certain brands will overheat when operating for long periods at full load In some cases the maximum current will ha...

Page 13: ...ust be programmed to zero So in this example the limits for AC1 AC3 and AC4 must be programmed to zero The display will then not alternate between and the set point for AC2 Summary Setting all but one of the Upper Shore limits to zero will stop the alternating of the display 6 5 Configuration examples Two examples are given to help you understand the setting of the parameters Example 1 Two VE Bus ...

Page 14: ...he configuration mode and you can change the scaling factor 2 Turn on the knob until the display indicates 7 3 Press the button to go to the next setting The lower left LED will turn on indicating that the generator current can be set 4 Turn on the knob until the display indicates 98 5 Press the button to advance to the Upper Shore limit for AC input 1 setting 6 You probably want the maximum shore...

Page 15: ...Body Aluminum NL Voedingsspanningbereik 9 70VDC Voedingsstroom Standby Actief 12V 5mA 30mA 24V 5mA 15mA Bedrijfstemperatuurbereik 0 50 C Afmetingen 65 x 120 x 55mm Netto gewicht 120 gram Materiaal Body Aluminium FR Plage de tension d alimentation 9 à 70VDC Courant d alimentation En Attente Actif 12V 5mA 30mA 24V 5mA 15mA Température de fonctionnement 0 à 50 C Dimensions 65 x 120 x 55mm Poids net 1...

Page 16: ...Betriebstemperatur 0 50 C Abmessungen 65 x 120 x 55mm Netto Gewicht 120 Gramm Material Gehäuse Aluminium ES Tensión de alimentación 9 70 VCC Corriente de alimentación En espera Activa 12V 5mA 30mA 24V 5mA 15mA Temperatura de funcionamiento 0 50 C Dimensiones 65 x 120 x 55mm Peso neto 120 gr Material Cuerpo Aluminio ...

Page 17: ......

Page 18: ...on 6 Date 24 April 2018 Victron Energy B V De Paal 35 1351 JG Almere PO Box 50016 1305 AA Almere The Netherlands General phone 31 0 36 535 97 00 Customer support desk 31 0 36 535 97 03 Fax 31 0 36 535 97 40 E mail sales victronenergy com www victronenergy com ...

Reviews: