FX Loop & Reverb Latching Push Switch 
This switch will completely bypass the FX Loop & the internal Digital Reverb when pushed in. This gives 
the purest possible signal path through the amplifier. 
 
FX Loop Latching Push Switch 
This switch will bypass the FX Loop when pushed in. The Reverb can then be independently switched 
ON/OFF using the front panel toggle switch or the supplied latching footswitch. 
 
Effects Loop  
The V40 has an effects loop, which is a simple, low impedance, series loop.  

The  SEND  socket  is  for  connection  to  the  input  of  effects  units.  On  the  V40  it  is  a  lower  impedance 
version of the signal that appears at the INPUT.  Use the send to connect to floor pedals or rack effects 
such as Delay, Chorus and Reverb etc. Effects such as Overdrive, Fuzz, Wah Wah and Tuners often give 
better results plugged into the Instrument Input on the front panel. The Send socket can also be used on 
its own to send a signal to another amplifier. 
The  RETURN  socket  is  for  connection  to  the  output  of  effects  units.  When  not  used  it  is  internally 
connected to the SEND, therefore the EFFECTS LOOP can be ignored if not in use. It can also be used as a 
small signal ‘Slave’ input from another amplifier but DO NOT plug an amplifier’s speaker output into the 
Return socket or very bad things will happen. 
 
 

Summary of Contents for V40 The Duchess

Page 1: ...User Guide VICTORY V40 The Duchess All Valve 40 Watt Guitar Head...

Page 2: ...from the wall outlet and refer servicing to qualified service personnel under the following conditions a When the power supply cord or plug is damaged b If liquid has been spilled or objects have fal...

Page 3: ...overdrive character Middle Controls the midrange frequencies in your sound Run the middle control higher to help cut through a band mix or generally fatten and widen your sound Run it lower for a ligh...

Page 4: ...nd low voltages on This allows the valves to heat up before they get 100s of volts up them it s less of a shock After around 60 seconds the amp can be switch to either HIGH around 42watts rms or LOW a...

Page 5: ...erious valve failure where internal parts of a valve are shorted and in this case the amplifier needs to be checked by a qualified engineer to assess the problem Speaker outputs PLEASE NOTE The lightn...

Page 6: ...nits On the V40 it is a lower impedance version of the signal that appears at the INPUT Use the send to connect to floor pedals or rack effects such as Delay Chorus and Reverb etc Effects such as Over...

Page 7: ...y output valves are changed the amplifier will need to be re biased This must be done by a qualified or competent person as there are lethal voltages inside the V40 and getting killed by a guitar ampl...

Page 8: ...amp is in Single ended mode measuring the available output is very subjective The following measurements were taken at 240V mains input into an 8 Ohm load using a 1 KHz Sine Wave with the output wavef...

Reviews: