Always use the correct rating and type of fuse. Victory amplifiers exclusively use UL-approved 20x5mm 
glass ‘T’ or ‘Timed’ fuses. If you have difficulty acquiring the correct fuses, please contact Victory using 

[email protected]

Mains inlet with Switch, (IEC Socket) 
Please only use the correct mains cord for your territory! The mains switch turns your amplifier ‘ON’. 
Ensure the front panel toggle switch is in the middle, ‘Standby’ position before turning on the mains. 
 
HT fuse 
The HT or ‘High Tension’ fuse protects the high voltage for the valve supply. If this fuse blows, the first 
step is to replace it with an identical T500mA 20x5mm fuse. The HT fuse may sometimes blow due to 
‘flash-over’ inside an output valve. This is where during the manufacturing process, not all of the gas is 
removed from the glass envelope and the ‘getter’ inside the valve, usually made from barium or 
magnesium oxide, will burn or evaporate these remaining gasses resulting in the common silvered 
internal surface of the valve. This process, which is more likely to happen with new equipment, draws 
high current momentarily and can blow the HT fuse. It will rarely cause any damage so just replacing the 
fuse is sufficient to get the amp running normally again. 
However, if the HT fuse blows again, it may indicate a serious valve failure where internal parts of a 
valve are shorted and in this case the amplifier needs to be checked by a qualified engineer to assess the 
problem.   
 
Speaker outputs 
PLEASE NOTE: The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to 
alert the user to the presence of uninsulated ‘dangerous voltage’ within the product’s enclosure that 
may be of sufficient magnitude to constitute a risk of electric shock. Terminals labelled as “Speaker 
Outputs” must be connected to a speaker cabinet of the designated load rating using an un-shielded two 
conductor cable for speaker use at all times during operation. Never use a guitar cable to connect the 
amplifier to a speaker as this presents the amplifier with a ‘capacitive load’. This can cause instability or 
oscillation which may seriously damage valves and/or the expensive output transformer. 
 
The output transformer in the V40 has 2 separate secondary windings; a 16 Ohm and an 8 Ohm. This 
makes it easy to connect different combinations of speakers. There are three speaker output jacks: 2 x 8 
Ohms, (wired in parallel) and 1 x 16 ohms. 
So here are the possible combinations: 

1.

 

For a single 8 Ohm cabinet, use either of the 8 Ohm sockets. 

2.

 

For a single 16 Ohm cabinet, use the 16 Ohm socket. 

3.

 

For a pair of 16 Ohm cabinets, use both of the 8 Ohm sockets. 

 
It is possible to use a pair of 8 Ohm cabinets with the V40 but a special series lead needs to be used.  
 
 
Over the page is a diagram of how this is achieved: 

Summary of Contents for V40 The Duchess

Page 1: ...User Guide VICTORY V40 The Duchess All Valve 40 Watt Guitar Head...

Page 2: ...from the wall outlet and refer servicing to qualified service personnel under the following conditions a When the power supply cord or plug is damaged b If liquid has been spilled or objects have fal...

Page 3: ...overdrive character Middle Controls the midrange frequencies in your sound Run the middle control higher to help cut through a band mix or generally fatten and widen your sound Run it lower for a ligh...

Page 4: ...nd low voltages on This allows the valves to heat up before they get 100s of volts up them it s less of a shock After around 60 seconds the amp can be switch to either HIGH around 42watts rms or LOW a...

Page 5: ...erious valve failure where internal parts of a valve are shorted and in this case the amplifier needs to be checked by a qualified engineer to assess the problem Speaker outputs PLEASE NOTE The lightn...

Page 6: ...nits On the V40 it is a lower impedance version of the signal that appears at the INPUT Use the send to connect to floor pedals or rack effects such as Delay Chorus and Reverb etc Effects such as Over...

Page 7: ...y output valves are changed the amplifier will need to be re biased This must be done by a qualified or competent person as there are lethal voltages inside the V40 and getting killed by a guitar ampl...

Page 8: ...amp is in Single ended mode measuring the available output is very subjective The following measurements were taken at 240V mains input into an 8 Ohm load using a 1 KHz Sine Wave with the output wavef...