background image

Page 10

Installations

 (refer to Page 4 for parts)

:

Measure the distance between stove top and the bottom of 

range hood. A distance of 28” to 31” is recommended*.

*Due to different ceiling height configurations, recom

-

mended height may not be applicable.

Using references in 

1. 

Height & Clearance

 on Page 5, mark 

the  leveling  point  of  the  hood.  Position  two  mounting 

screws  on  the  wall,  leaving  1/8”  space  away  from  the 

wall.

Measure the width of the chimney then attach the chim

-

2. 

ney-mounting brackets to the wall as high as you want 

the upper chimney to be.

NOTE: Use threaded drywall anchors only when mount

-

ing the hood on sheet rock. Mounting the hood on wall 

studs or lumbars is highly recommended.

Align hood-mounting holes to the screws on the wall and 

3. 

hook the hood into place. Tighten screws to secure hood 

to the wall. 

CAUTION: Make certain the range hood 

is secure before releasing!

Connect the venting duct between the hood and the ex

-

4. 

haust opening either on the ceiling or wall. Use alumi-

num tape to make all joints secure and air tight. 

Connect the range hood to a designated standard outlet (please refer the product label for the suitable voltage 

5. 

of this unit) or cut off the plug and connect three wires (black, white and green) to house wires and cap with 

wire connectors. Connect according to colors (i.e. black to black, white to white, and green to green).

SAFETY WARNING: Risk of electrical shock. This range hood must be properly grounded. Make sure 

this is done by qualified electrician in accordance with all applicable national and local electrical codes. 

Before connecting wires, switch power off at service panel and lock service panel to prevent power from 

being switched on accidentally.

Installation

Figure 1

DO NOT INSTALL THE RANGE HOOD BEFORE TESTING IT. MECHAN

-

ICAL DAMAGE MIGHT HAVE OCCURRED DURING TRANSPORTION.  

Plug in the range hood to the USA/Canada 120V standard outlet (220V for Eu

-

rope and other countries), test the blower and the lights before installing it.

Summary of Contents for 218B2-30

Page 1: ...Hood NOTICE Installer Leave this guide with the homeowner Homeowner Keep this guide for future reference IMPORTANT Read and save these instructions Rev 1024u 4a VICTORY 218 Series Wall Mounted Range H...

Page 2: ......

Page 3: ...authorities Before servicing or cleaning unit switch power OFF at service panel and lock service panel to pre vent power from being switched ON accidentally Clean grease laden surfaces frequently To...

Page 4: ...o out immediately EVACUATE AND CALL THE FIRE DEPARTMENT or dial your local emergency service immediately DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result Use a...

Page 5: ...tion 9 Installation 10 11 Installation overview 11 USE AND CARE Range hood operations 12 13 Troubleshooting 14 Use and care information 15 Specifications 15 Wiring diagram 16 MAINTENANCE Cleaning repl...

Page 6: ...en ordered together with range hood Parts supplied Hex Key Qty 1 PCS Optional with glass canopy Glass Canopy Screw Qty 4 PCS Optional with glass canopy Qty 6 PCS For sheet rock only A Qty 6 PCS B Qty...

Page 7: ...of the vent should be uniform Use no more than three 90 elbows Make sure there is a minimum of 24 61 cm of straight vent between the elbows if more than one elbow is used DO NOT install two elbows tog...

Page 8: ...elbows transitions and caps ALWAYS when possible reduce the number or transitions and turns If long duct run is required increase duct size from 6 to 7 or 8 If a reducer is used install a long reduce...

Page 9: ...esellers The standard aluminum filters are intended to capture residue from cooking the optional charcoal filters help to purify fumes exhausted from cooking and the optional air diverter redirects fi...

Page 10: ...0 Hz AC only USA Canada standard DO NOT ground to a gas pipe Check with a qualified electrician if you are not sure that the range hood is properly grounded DO NOT have a fuse in the neutral or ground...

Page 11: ...the 1 range hood will be installed Make sure there is proper clear ance within the ceiling or wall for exhaust vent Due to the weight and size of this unit please make sure that 2 the support system o...

Page 12: ...he venting duct between the hood and the ex 4 haust opening either on the ceiling or wall Use alumi num tape to make all joints secure and air tight Connect the range hood to a designated standard out...

Page 13: ...To avoid scratching the chimney extend the upper 8 chimney slowly and carefully to the chimney mount ing bracket and tighten screws as shown in Figure 6 Turn power ON in control panel Check all light...

Page 14: ...tem is running Power Off Delay Digital Timer Indicates the length of time left for delay off function Power Off Delay Timer Indicator Lights up when auto shutdown delay timer function is on Controls A...

Page 15: ...will shut down Adjusting the light Press Light button once to turn on the lights and once again to turn off the lights While the lights are off press and hold Light button for over 3 seconds to dim th...

Page 16: ...t installed correctly or opening properly A tight mesh on a side wall cap unit might also cause restriction to the air flow The lights work but the blower is not spinning at all 4 is stuck or is rattl...

Page 17: ...s operating blowers could catch on to hair fingers and loose clothing NEVER dispose cigarette ashes ignitable substances or any foreign objects into blowers NEVER leave cooking unattended When frying...

Page 18: ...Page 16 Wiring Diagram Six Speed with Type GU10 Bulb...

Page 19: ...steel wool or steel brushes Small bits of steel may adhere to the surface and cause rusting DO NOT allow salt solutions disinfectants bleaches or cleaning compounds to remain in contact with stainless...

Page 20: ...s unplugged or turn OFF breaker Make sure the lights are cool to touch carefully align the arrow on the inner ring with the arrow on the outer ring where it says OPEN with the Inner Ring Opener as sho...

Page 21: ...sumable parts such as light bulbs metal and charcoal filters The natural wear of finish and wear due to improper maintenance use of corrosive and abrasive cleaning products pads and oven cleaner produ...

Page 22: ...ng fee of 15 will be charged for all approved return s Exchanges or returns may not be accepted if any packaging is missing Make sure to inspect the hood for damages and defects before installation Ap...

Page 23: ...Your Notes Page 21...

Page 24: ...7272 Buller Ave Burnaby BC V5J4S3 Canada VICTORY range hoods...

Reviews: