VICTORY  CORPORATION  DOES  NOT  SERVICE,  MAINTAIN  OR  RECHARGE  FIRE 

EXTINGUISHERS.    THIS MANUAL IS PUBLISHED AS A GUIDE TO ASSIST QUALIFIED 

SERVICE  PERSONNEL  IN  THE  INSPECTION,  MAINTENANCE  AND  RECHARGE  OF 

VICTORY  FIRE  EXTINGUISHERS  ONLY.    NO  INSTRUCTION  MANUAL  CAN 

ANTICIPATE ALL POSSIBLE MALFUNCTIONS THAT MAY BE ENCOUNTERED IN THE 

SERVICE  OF  FIRE  EXTINGUISHERS.    DUE  TO  THE  POSSIBILITY  THAT  PRIOR 

SERVICE PERFORMED  ON THIS EQUIPMENT  MAY HAVE  BEEN  IMPROPERLY DONE, 

IT  IS  EXTREMELY  IMPORTANT  THAT  ALL  WARNINGS,  CAUTIONS  AND  NOTES  IN 

THIS  MANUAL  BE  CAREFULLY  OBSERVED.    FAILURE  TO  HEED  THESE 

INSTRUCTIONS COULD RESULT IN SERIOUS INJURY.   

   

VICTORY ASSUMES NO LIABILITY FOR SERVICE, MAINTENANCE OR RECHARGE OF 

FIRE EXTINGUISHERS BY PUBLISHING THIS MANUAL.

   

 

 

 

 

 

 

 

 

 

 

 

 

 

REFERENCES IN THIS MANUAL:

                                     

AVAILABLE FROM:

   

 

NFPA 10   

Standard for Portable Fire Extinguishers       

National Fire Protection Association   

                  

2022 Edition                                                   

1 Batterymarch Pk. P.O Box 9101   

                                                                                             

Quincy, MA. 02169-7471   

                                                                                               

www.nfpa.org

   

CGA C-1     

Methods for Hydrostatic     

 

 

 

Compressed Gas Assoc., Inc.           

Testing of Compressed Gas         

 

 

4221 Walney Road., 5th floor   

                     

Cylinders                                             

 

Chantilly, VA. 20151-2923   

                                                                                                 

www.cganet.com

 

CGA C-6     

Standard For Visual Inspection   

of Steel Compressed Gas Cylinders  

 

Victory Fire & Gas Inc.   

1713 Lewis Street, Bay City,   

MI. 48706. Office - 989.322.0856. 

E-Mail: 

[email protected]

,   

http://www.victoryfiregas.com

   

Summary of Contents for WM2.5GAL

Page 1: ...at they are ready to operate properly and safely Victory strongly recommends that the maintenance of portable fire extinguishers be done by a trained professional your local authorized Victory Distrib...

Page 2: ...D FAILURE TO HEED THESE INSTRUCTIONS COULD RESULT IN SERIOUS INJURY VICTORY ASSUMES NO LIABILITY FOR SERVICE MAINTENANCE OR RECHARGE OF FIRE EXTINGUISHERS BY PUBLISHING THIS MANUAL REFERENCES IN THIS...

Page 3: ...to 49 C please see the nameplate on your extinguisher The extinguisher should be adequately protected if temperatures outside of this range are anticipated Keep the extinguisher clean and free from d...

Page 4: ...the extinguisher in a vertical position aim the nozzle at the base of the fire 5 Approach fire from upwind minimum of 10 feet of the front edge of the fire 6 Starting back from this distance squeeze t...

Page 5: ...sher connected to a regulator of a high pressure source for an extended period A defective regulator could cause the cylinder to rupture due to excessive pressure CAUTION Discharge time and effective...

Page 6: ...ondition to prevent its operation and any necessary repair or replacement It will normally reveal if hydrostatic testing or internal maintenance is required Maintenance servicing recharging shall be p...

Page 7: ...te the class C capability Do not mix deionized water with non deionized in extinguisher content 6 Visually inspect the pressure gauge a If bent damaged or improper gauge depressurize and replace b If...

Page 8: ...could seriously damage the plastic gauge face 3 Inspect the extinguisher for damaged missing or substitute parts NOTE Only factory replacement parts are approved for use on victory fire extinguishers...

Page 9: ...disassembled valve with a soft bristle brush or soft cloth Blow the valve out with air or nitrogen Inspect the collar O ring valve stem spring and dip tube assembly and replace parts if worn or damage...

Page 10: ...ing facing the front of the extinguisher gauge side 12 Install new tamper seal wrapping through loop and around levers to secure ring pin Do not over stress tamper seal 13 Weigh assembled extinguisher...

Page 11: ...ent De pressurize and replace Install the correct Victory pressure gauge using Teflon tape on the gauge threads 9 Gauge does not indicate compatible with brass De pressurize and replace Install the co...

Page 12: ...will not affect the remainder Victory is not responsible for the installation or the maintenance of the products Defective products for which a valid claim has been made shall be returned to Victory s...

Page 13: ...sociation 2022 Edition 1 Batterymarch Pk P O Box 9101 Quincy MA 02169 7471 www nfpa org CGA C 1 Methods for Hydrostatic Compressed Gas Assoc Inc Testing of Compressed Gas 4221 Walney Road 5th floor Cy...

Page 14: ...14 APPENDIX A...

Page 15: ...ch Pressure Gauge to valve Recommended torque 5 12Nm 44 106 in lbs with sealant glue Scales Filling cylinders with deionized water Recommended accuracy 2 5 or better Pressurizing recharging adaptors S...

Reviews:

Related manuals for WM2.5GAL