03.2021
INSTRUCTION MANUAL
for installation and operation of pellet stove
VITTORIA 8
5
Technical data and nominal performance:
The dimensions of the heated room are calculated based on pellets with calorific value not less than 4300 ccal/kg and heat loss
of heated room 33 ccal/m³h.Consideration must be
given to the availability of external devices that can influence the operation
of the pellet stove.
All activities for repairing of electrical components, maintenance and / or inspections should be performed by
qualified personnel. Unplug the appliance from the main electrical supply before you start these activities.
Electrical data:
Performance parameters:
Power supply
230 Vac (+/-10
Switch on / off
Yes
Average power consumption
130 W
Average power consumption during ignition
430 W
Main power protection
Fuse
4А, 250 VAC5 х 20
4.Safety devices.
Fume thermocouple:
It is placed at the exit of the flue socket to measure the temperature of the flue gases.
Control’s
ignition
and at very high temperature (260
0
C) triggers lock phase. Alarm (
Exhaust gases
).
Pressostat
: Connected to the combustion chamber. It reads the values of the vacuum in the combustion chamber and compares
it with the pressure in the room.
Temperature sensor of the pellet fuel hopper:
Placed on the auger housing near the pellet fuel hopper. It interrupts feeding of
the pellets when its temperature reaches
75°С.
Fuse:
At the main switch of the pellet stove there is built in fuse.
Technical data
:
Performance parameters:
Nominal heat output
6.1 kW
Reduced heat output
3.0 kW
Maximum operating temperature
260
°
С
Distance to adjacent combustible materials
Side = 300 mm
Rear = 300 mm
in front = 800 mm
Efficiency
87.76 %
СО emissions [13% О
2
]
at nominal heat output
at reduced heat output
0.0166 %
0.0281 %
Flue gases temperature
at nominal heat output
at reduced heat output
125
°
С
78
°
С
Flue gases mass
at nominal heat output
at reduced heat output
5.81 gr/s
2.96 gr/s
Draught
at nominal heat output
at reduced heat output
11 Ра
11 Pa
Duration of combustion
at nominal heat output
at reduced heat output
15h
34h
Fuel consumption minimum / maximum
0.7 / 1.525 kg/h
Type and dimensions of fuel
Wood pellets, Ø 6 mm/length 25 mm
Pellet fuel hopper capacity
24 kg
Flue socket diameter
Ø 80 mm
Heating volume
≈ 120
m
3
Net weight
103 kg
Summary of Contents for VITTORIA 8
Page 1: ...INSTRUCTION MANUAL for installation and operation of air pellet stove VITTORIA 8...
Page 4: ...Victoria 05 Ltd 4 3 Technical data and dimensions Drawing 1...
Page 20: ...Victoria 05 Ltd 20...
Page 21: ...03 2021 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 21...
Page 22: ...Victoria 05 Ltd 22...