background image

853377-1204i

MODEL: US2000E

Certified to: UL 1482-2011 (R2015) and 

ULC-S627-00 (R2016)

Mobile home approved (U.S. ONLY)

U.S. Environmental Protection Agency

Certified to comply with 2020 

particulate emissions standards.

R

CALIFORNIA PROPOSITION 65 WARNING:

This product can expose you to chemicals including carbon monoxide, which 

is known to the State of California to cause cancer, birth defects and/or other 

reproductive harm. For more information, go to www.P65warnings.ca.gov

Ce produit peut vous exposer à des agents chimiques, y compris au monoxyde de 

carbone, lesquels sont reconnus dans l’État de la Californie comme causant le cancer et 

des malformations congénitales ou autres dommages au fœtus. Pour obtenir plus de 

renseignements, veuillez consulter le site www.P65warnings.ca.gov

Report Number: F19-476

SAFETY NOTICE:

If this heater is not properly installed, a house fire may result. 

For  your  safety,  follow  the  installation  instructions.  Never 

use make-shift compromises during the installation of this 

heater. Contact local building or fire officials about permits, 

restrictions and installation requirements in your area.

CAUTION!

Please read this entire manual before you install or use your 

new room heater. Failure to follow instructions may result in 

property damage, bodily injury, or even death. Improper 

Installation Could Void Your Warranty!

Save  these  instructions.  This  manual  will  help  you  to  obtain 

efficient, dependable service from the heater, and enable 

you to order repair parts correctly. Keep in a safe place for 

future reference.

United States Stove Company

PO Box 151, 227 Industrial Park Rd.,

South Pittsburg, TN 37380

PH: (800) 750-2723

www.usstove.com

Summary of Contents for Forester US2000E

Page 1: ...veuillez consulter le site www P65warnings ca gov Report Number F19 476 SAFETY NOTICE If this heater is not properly installed a house fire may result For your safety follow the installation instructi...

Page 2: ...od Colors Metallic Black Flue Pipe Diameter 6 152 5 mm Flue Pipe Type Standard Single Wall or Double Wall Black or Blued Steel 2100 F 650 C Minimum Chimney Height 12 3 7 m Maximum Log Length 21 533 5...

Page 3: ...surfaces Fix the assembly to the back of the stove with the four screws provided ASH PAN ASSEMBLY Remove ash pan from firebox Under the firebox there are two brackets Slide the ash pan into these brac...

Page 4: ...me is spent and in the most spacious room possible Recall that wood stoves produce radiating heat the heat we feel when we are close to a wood stove A wood stove also functions by convection that is t...

Page 5: ...of the unit The clearance between the flue pipe and a wall are valid only for vertical walls and for vertical flue pipe The chimney connector must not pass through an attic or roof space closet or sim...

Page 6: ...er or not there is combustion present 2 Existing fuel fired equipment in the house such as fireplaces or other heating appliances smell do not operate properly suffer smoke roll out when opened or bac...

Page 7: ...MUST BE ATTACHED TO THE STRUCTURE OF THE MOBILE HOME SECURING APPLIANCE S ON A PEDESTAL TO THE FLOOR Use the designated holes to secure the unit to the floor SECURING APPLIANCE S WITH LEGS TO THE FLOO...

Page 8: ...o the room through appliance and chimney connector joints An uncontrollable burn or excessive temperature indicates an excessive draft CHIMNEY Your wood stove may be hooked up with a 6 factory built o...

Page 9: ...as recommended by the manufacturer The chimney must be the required height above the roof or other obstructions for safety and proper draft operation MASONRY CHIMNEY Ensure that a masonry chimney meet...

Page 10: ...connector Use this as a pass through for a minimum 24 gauge single wall steel chimney connector Keep solid pak section concentric with and spaced 1 25 4 mm off the chimney connector by way of sheet m...

Page 11: ...rain or snow also accelerates the drying time A good indicator of if the wood is ready to burn is to check the piece ends If cracks are radiating in all directions from the center then the wood shoul...

Page 12: ...s the stove s efficiency and leads to accelerated creosote buildup in your chimney TESTING YOUR WOOD When the stove is thoroughly warmed place one piece of split wood about five inches in diameter par...

Page 13: ...h of the chimney altitude and outside temperature EFFICIENCY Efficiencies can be based on either the lower heating value LHV or the higher heating value HHV of the fuel The lower heating value is when...

Page 14: ...500 F heat is wasted since a too large quantity is lost into the atmosphere TO PREVENT CREOSOTE BUILD UP Always burn dry wood This allows clean burns and higher chimney temperatures therefore less cre...

Page 15: ...damaged piece with a new one Perform the procedure backward after replacing it When replacing the glass you should change the glass gasket to make sure you keep it sealed Never wash the glass with a p...

Page 16: ...on Qty 1 40292A 6 Flue Collar 1 2 88042 Rope Gasket 1 4 1 3 25845 Air Deflector 1 4 891492 Blower Assembly B36 1 5 26060 Rear Shield 1 6 610926 Rear Ashpan US2000E BP 1 7 29068 Pedestal US2000E BP 1 8...

Page 17: ...11 64 1 5 29039 Brick Retainer left 1 6 29040 Brick Retainer right 1 7 40561 Ash Plug 1 8 24103A Half Pumice Firebrick 4 1 2 X 4 1 2 2 9 891414A Half Firebrick 2 10 89066A Pumice Firebrick 4 1 2 X 9...

Page 18: ...7 Date _____________________ Engineer Name ________________________________ License No ____________________________________ Company _____________________________________ Telephone No _________________...

Page 19: ...ECHANGE VEUILLEZ CONSERVER CE GUIDE DANS UN ENDROIT S R DES FINS DE R F RENCE LORSQUE VOUS NOUS CRIVEZ VEUILLEZ INDIQUER LE NUM RO COMPLET DU MOD LE QUI FIGURE SUR LA PLAQUE SIGNAL TIQUE DE L APPAREIL...

Page 20: ...__________________________ Service de 07 Date _____________________ Nom de l ing nieur ____________________________ N de licence _________________________________ Compagnie ___________________________...

Page 21: ...1 5 29039 retenue de brique gauche 1 6 29040 retenue de brique droite 1 7 40561 bouchon de cendre 1 8 24103A brique r fractaire demi pierre ponce 4 1 2 x 4 1 2 2 9 891414A demi brique r fractaire 2 1...

Page 22: ...610922 socle soud US2000E BP 1 10 610925 cendrier US2000E BL 1 11 40566 pied en fonte US2000E BL 4 12 25826 plaque de foyer 1 13 29216 cendrier 1 14 610927 soudure de glissi re d amortisseur 1 15 610...

Page 23: ...bien tanche Ne lavez jamais la vitre avec un produit qui pourrait la rayer Utilisez un produit sp cialis disponible dans les magasins qui vendent les po les bois La vitre doit tre nettoy e uniquement...

Page 24: ...z toujours du bois sec Cela permet des combustions propres et des temp ratures de chemin e sup rieures et par cons quent moins de d p t de cr osote Laissez la commande d air compl tement ouverte penda...

Page 25: ...ales est d apprendre les caract ristiques de br lage de votre appareil et du bois bien s ch Des taux de combustion plus lev s ne sont pas toujours les meilleurs taux de combustion apr s qu un bon feu...

Page 26: ...pouces de diam tre parall lement la porte sur le lit de braises rouges Maintenez la commande d air compl tement ouverte en tirant dessus et fermez la porte Si l allumage de la pi ce se fait en moins d...

Page 27: ...t normalement tre consid r comme sec 66 Fendre et empiler le bois avant de l entreposer acc l re son s chage Entreposez le bois sur une surface sur lev e du sol et sous un espace abrit de la pluie ou...

Page 28: ...LE PO LE DOIT TRE FIX LA STRUCTURE DE LA MAISON MOBILE UTILISEZ LES DEUX 2 TROUS AU FOND DU PI DESTAL DE LA RADIATEUR POUR FIXER L APPAREIL AU SOL Illustration Fixation du r chauffeur au plancher Uti...

Page 29: ...des mati res combustibles 2 Les appareils foyer existants au sein du domicile tels que des chemin es ou d autres appareils de chauffage mettent des odeurs ne fonctionnent pas correctement mettent des...

Page 30: ...stible Commencez avec une partie de chemin e Solid Pak fabriqu e en usine agr e d au moins 12 po 304 mm de diam tre int rieur avec une isolation de 1 po 25 4 mm ou plus et un raccord de chemin e de 8...

Page 31: ...n bon tirage CHEMIN E EN MA ONNERIE Assurez vous qu une chemin e en ma onnerie r ponde aux standards minimum de l Association nationale de protection contre les incendies NFPA en la faisant inspecter...

Page 32: ...emble avec un ciment r fractaire les carneaux cylindriques sont les plus efficaces Le diam tre int rieur du carneau de chemin e doit tre identique l aspiration des fum es du po le Un carneau trop peti...

Page 33: ...tirage n est pas recommand e En effet avec un po le bois de combustion contr l e le tirage est r gul d s l admission de l air de combustion dans le po le et non l vacuation D GAGEMENTS AVEC LES MATI R...

Page 34: ...pr s possible de la chemin e et dans un endroit propice la distribution de chaleur la plus efficace possible dans toute la maison Le po le doit donc tre install dans la pi ce o le plus de temps est p...

Page 35: ...SUR DES SURFACES CHAUDES ASSEMBL E DE CASSEROLE DE CENDRE Enlevez la casserole de cendre du foyer Sous le foyer il y a deux parenth ses Glissez la casserole de cendre dans ces parenth ses ASSEMBLAGE...

Page 36: ...OUR D MARRER LE FEU NE LAISSEZ PAS LE PO LE SANS SURVEILLANCE LORSQUE LA PORTE EST L G REMENT OUVERTE NE BR LEZ PAS DE D CHETS NI DE FLUIDES INFLAMMABLES TELS QUE L ESSENCE LE NAPTHA OU L HUILE POUR M...

Page 37: ...U PO LE EFFICACE ET FIABLE ET VOUS PERMETTRA DE COMMANDER CORRECTEMENT TOUTE PI CE D TACH E GARDEZ LE DANS UN LIEU S R POUR TOUTE CONSULTATION ULT RIEURE MOD LES US2000E U S Environmental Protection A...

Reviews: