Step six: neaten the pipes
Outdoor Condensate Drainage (only for Heat pump unit)
1. The pipes should be placed along the wall,
bent reasonably and hidden possibly. Min.
semidiameter of bending the pipe is
4in(
10cm
)
.
2. If the outdoor unit is higher than the wall
hole, you must set a U-shaped curve in the
pipe before pipe goes into the room, in
order to prevent rain from getting into the
room.
Installation of outdoor unit
U-shaped curve
wall
drain hose
2. Fix the power connection wire and signal control wire with wire clip (only for
cooling and heating unit).
Note:
● Never cut the power connection wire to prolong or shorten the distance.
During heating operation, the condensate and
defrosting water should be drained out reliably
through the drain hose. Install the outdoor
dr
ain connector in a Φ
1
hole or Φ
1
hole on
the base plate and attach the drain hose to the
connector so that the waste water formed in
the outdoor unit can be drained out. The hole
diameter
Φ
1
or
Φ
1
must be plugged.
Whether to plug other holes will be determined
by the dealers to actual conditions.