Fig. 12
Fig. 13
49
48
EN
49
• The set pump pressure is displayed in the bottom
section "B" of the pressure gauge, inside the
machine (see Fig. 12);
• The pressure set on the pressure switch is dis-
played in the top section "C" of the pressure gauge,
inside the machine (see Fig. 12);
At the end of the adjustment process, refit the sheet
metal guard on the relevant housing and secure it in
place with the two side screws. Refit the drip tray and
the work surface grid.
• To access the pressure gauge, remove the cup
warmer section on the left by loosening the two
screws "D" as illustrated in the following figure.
5.3 HOT WATER ECONOMISER
ADJUSTMENT
NOTE
This operation can be carried out while the machine
is turned on.
All models ADONIS are equipped with a hot water mixer
tap which adjusts the water temperature and optimises the
system’s performance.
To adjust the hot water economiser, turn the registration
knob.
• The hot water economiser is located inside the
machine.
C
B
D