![Victoria Arduino Adonis+ 2 Gr Technical Manual Download Page 77](http://html1.mh-extra.com/html/victoria-arduino/adonis-2-gr/adonis-2-gr_technical-manual_1013902077.webp)
75
EN
Use
the
WV
keys to vary the starting up time.
Press
ENTER
to confirm and to go on to the pro-
grammed switching off time (the message OFF
23.30 will start to flash on and off).
Use
the
WV
keys to vary the switching off time.
Confirm
by
pressing
ENTER
.
To de-activate the on/off function on weekly day-off,
press
RESET
.
The display will read:
(to reinstate, press
RESET
)
After the word SUNDAY, by pressing
W
again, a
beep will signal that you have come to the following
page.
ENERGY SAVING (stand-by)
The display will read:
This function allows the machine to enter an active
STANDBY status, where it is possible to choose whether
to switch off the machine completely or to keep it at a set
pressure (lower than working pressure).
Press
ENTER
and the display will read:
Here it is possible to select the XXX mode using the
WV
keys.
The 4 operating modes are:
OFF: during STANDBY the machine is switched off
and the display reads "
OFF
";
STANDBY 0.10 bar: during STANDBY, the machine
maintains a pressure of 0.10 bar and the display (set
to minimum brightness) reads "
LOW POWER USE
";
STANDBY 0.50 bar: during STANDBY, the machine
maintains a pressure of 0.50 bar and the display (set
to minimum brightness) reads "
LOW POWER USE
";
STANDBY 0.80 bar: during STANDBY, the machine
maintains a pressure of 0.80 bar and the display (set
to minimum brightness) reads "
LOW POWER USE
".
This type of operation is possible when switching the
machine on/off manually using the
RESET
key and
when switching the machine on/off automatically using
the ON/OFF programming function.
If the RES key is pressed while the machine is in one
of the standby conditions (0.10 bar, 0.50 bar, 0.80 bar),
the machine switches to OFF. If the key is pressed
again, the machine enters the ON mode.
Press the
ENTER
key to confirm the mode selected
from the display and go back.
Press the
RESET
key to go back without confirming.
SETPOINT TEMPERATURE
(AND OFFSET) (Version T3 only)
It is possible to access this function by pressing the
ENTER
key .
The
W V
key serves to adjust the temperatures
of the boilers and units; the
ENTER
key is used to
confirm and pass to the next value. When the last
DAY OFF
ENERGY SAVING
ENERGY SAVING
XXX
Summary of Contents for Adonis+ 2 Gr
Page 1: ...dal 1905 manuale tecnico d uso technical manual manuel technique de mode d emploi...
Page 2: ......
Page 4: ...2 IT...
Page 48: ...46 EN...
Page 90: ...88 EN...
Page 92: ...90 FR...
Page 135: ......