5.1 FILLING BOILER MANUALLY
NOTE
This operation must be carried out with the machine
turned off.
All models
are equipped with a level gauge
to keep the water level inside the boiler constant.
When using the machine for the first time, it is advisable
to fill the boiler by hand to avoid damaging the electrical
resistor and turning on the electronic protection.
If this should happen, just turn the machine off and then
start it up again to complete its loading procedure (see
chapter “
MACHINE FUNCTIONS MESSAGE – LEVEL
ERROR
”).
To fill the boiler manually for the first time, proceed
as follows:
remove the grid and the drip tray;
remove the protective metal sheet by unscrewing
the two side screws
"A"
as shown in the following
illustration;
turn the manual
“A”
level tap so that water will
enter the boiler;
after about 45 seconds, shut off the valve
”A”
as
illustrated in the following figure;
switch on the machine (see the chapter
“
SWITCHING ON THE MACHINE
”).
5. ADJUSTMENTS TO BE MADE BY A QUALIFIED TECHNICIAN ONLY
Fig. 8
Fig. 7
A
A