3
BLOWN AIR WELL / DELI (Where purchased)
THE WELL IS DESIGNED TO MAINTAIN FOOD PLACED IN THE WELL AT BETWEEN 3
O
AND 5
O
C
IN AMBIENT TEMPERATURES OF UP TO 25
O
C AND RELATIVE HUMIDITIES UP TO 60%; FOOD
PLACED IN THE WELL MUST BE AT OR BELOW THIS TEMPERATURE, BEFORE BEING PLACED IN
THE WELL.
The refrigeration system is operated by a green on / off switch marked ‘REFRIGERATION’,
which will illuminate when the refrigeration is switched on.
The refrigeration system is controlled by a microprocessor control which is factory set and
requires No adjustment, the digital display will show the air temperature within the well,
not the food temperature. Other buttons on the controller are of no consequence to the
user and are for factory or service engineer use only.
To obtain the best performance, the following procedure is suggested:
(a)
Switch on the refrigeration system via the switch located on the control panel.
(b)
Depending on the ambient temperature, allow the well approximately 30 minutes
to reach the required temperature.
(c)
Load the well as required, be careful not to over pack the well and restrict
airflows between the front and rear vents of the well as this will affect the
efficiency of the refrigeration system. Do not fill above the “Load Lines” marked
on the sides of the unit.
All refrigeration systems frost up when operating. Your appliance has a microprocessor
control, programmed to defrost periodically. No manual defrost is required. The
refrigeration system will automatically defrost every 2 hours for approximately 20 minutes.
The controller will display ‘def’ during the defrost cycle. Water collected from the defrost
operation is automatically evaporated.
Please remember the refrigeration system is not designed to chill food, but is designed to
maintain it at a satisfactory temperature before serving.
MULTI-TIER DISPLAY (Where purchased)
THE DISPLAY IS DESIGNED TO MAINTAIN FOOD PLACED IN THE DISPLAY AT BETWEEN 3
O
AND
5
O
C IN AMBIENT TEMPERATURES OF UP TO 25
O
C WITH A RELATIVE HUMIDITY OF 60%; FOOD
PLACED IN THE WELL MUST BE AT OR BELOW THIS TEMPERATURE, BEFORE BEING PLACED IN
THE WELL.
The refrigeration system is operated by a green on / off switch marked ‘REFRIGERATION’,
which will illuminate when the refrigeration is switched on. The lighting is controlled by an
adjacent green on / off switch marked “light” See “gantry” section below for method of
replacing fluorescent lamps.
The refrigeration system is controlled by a microprocessor control which is factory set and
requires No adjustment, the digital display will show the air temperature within the well,
not the food temperature. Other buttons on the controller are of no consequence to the
user and are for factory or service engineer use only.