Victor 6000counts Instruction Manual Download Page 9

                                                                         

6000counts Pocket Clamp Multimeter 

 4) It is forbidden to input voltage values exceeding 250V DC or AC peak to avoid damage to the meter. 

3-8. Temperature measurement ( 

°

C/

°

F) 

The operation is as follows: (top right) 

1. Dial to the

TEMP

file; 

2. Insert the two input ends of the temperature probe into the 

V/

Ω

/Hz

  and 

COM

  terminals of the red test pen. The test probe is inserted into 

the measured water, and the temperature of the measured water will be displayed on the LCD. 

3. Press the SELECT button to toggle between Celsius and Fahrenheit (

°

C/

°

F). 

Note: 

1)

 

It is forbidden to input voltage values exceeding 250V DC or AC peak to avoid dama ge to the meter. 

3-9. Square wave output

               

 

The operation is as follows: (top right) 

1 Dial to 

         

; (default starting output is 50Hz); 

2. Insert the two inputs of the device under test into the 

V/

Ω

/Hz

  and 

COM

  terminals of the red test pen. 

3.Trigger 

the

SELECT 

”  button.  The 

V/

Ω

/Hz” 

and 

COM

terminals 

of 

the 

table 

respectively 

output 

50Hz-100Hz-200Hz-300Hz-400Hz-500Hz-600Hz-700Hz-800-Hz-900Hz-1000Hz-2000Hz  -3000Hz-4000Hz-5000Hz.  At  the  same  time,  the  LCD 

screen displays the current output value. 

Note: 

1) It is forbidden to input voltage values exceeding 250V DC or AC peak to avoid damage to the meter.  

3-10. NCV measurement; 

The operation is as follows: 

1. dial to the 

NCV

  position; (in the no-measure state LCD displays 

EF

); 

2.  The  front  end  of  the  meter  has  NCV  test  points.  As  long  as  the  point  is  close  to  the  AC  voltage,  the  buzzer  will  emit  different  continua tions 

according to the different strength of the signal, and the LCD will also display according to the strength of the signal. Different number of segments. 

                        Accuracy 

Range 

                                      6000counts 

          Resolution 

(-20-1000 )

 

±(

1.0%+5

)<400℃

;     

±(

1.5%+15

)≥400℃

 

1

 

(0-1832 )

 

±(

0.75%+5

)<750℉

;     

±(

1.5%+15

)≥750℉

 

1

 

Summary of Contents for 6000counts

Page 1: ...6000counts Pocket Clamp Digital Multimeter Instruction Manual...

Page 2: ...en measuring voltage do not input a limit voltage exceeding the effective value of DC 1000V or AC 750V 2 The voltage below 36V of the current file is a safe voltage when measuring AC voltage higher th...

Page 3: ...ng least significant digit to ensure accuracy Ambient temperature 23 5 relative humidity 75 calibration guarantee period from the date of manufacture for one year 2 2 Performance Note indicates that t...

Page 4: ...input value 3 The test pen is reliably contacted with the test point and the screen displays the measured voltage value When measuring the DC voltage display the red test pen is the voltage polarity o...

Page 5: ...e to the instrument circuit 3 When measuring high voltage circuits special care should be taken to avoid electric shock 4 After completing all measurement operations please disconnect the test leads f...

Page 6: ...position trigger the SELECT key and select the resistance file to automatically measure Note 1 When measuring low resistance the test leads will bring internal resistance To obtain accurate reading y...

Page 7: ...e tested The reading is an approximation of the forward voltage drop of the diode For a silicon PN junction it is typically about 500mV 800mV is confirmed as normal value if the diode under test is op...

Page 8: ...ting the capacitor capacity to prevent damage to the fuse and meter 4 Unit 1F 1000mF 1mF 1000uF 1uF 1000nF 1nF 1000pF 3 7 Frequency measurement Input sensitivity 1V rms overload protection 550V DC or...

Page 9: ...two inputs of the device under test into the V Hz and COM terminals of the red test pen 3 Trigger the SELECT button The V Hz and COM terminals of the table respectively output 50Hz 100Hz 200Hz 300Hz 4...

Page 10: ...ndow 6 COM input negative input insert black test pen 7 Voltage resistance diode capacitor frequency square wave output current input port 8 HOLD is the data hold button long press for 2 seconds for t...

Page 11: ...method Not shown Battery not connected Replace the battery Low battery symbol Replace the battery Current is not input Replace fuse Resistance display error The test pen is not in contact This manual...

Reviews: