Victor 6000counts Instruction Manual Download Page 8

                                                                         

6000counts Pocket Clamp Multimeter 

3. Then connect the test leads across the capacitors under test. 

Note: 

    1)  When  measuring  capacitance  with  10nF  file,  there  may  be  residual  reading  on  the  screen  display  value.  This  number  is  the  d istributed 

capacitance of the test pen. It is an accurate reading and can be subtracted after measurement. 

    2)  When  the  large  capacitance  file  measures  severe  leakage  or  breakdown  capacitance,  some  values  will  be  displayed  and  unstable;  when 

measuring large capacitance, the reading takes several seconds to stabilize, which is normal when measuring large capacitance; 

        3) Please fully discharge the capacitor before testing the capacitor capacity to prevent damage to the fuse and meter.  

4) Unit: 1F=1000mF, 1mF=1000uF, 1uF=1000nF, 1nF=1000pF 

3-7 Frequency measurement 

Input sensitivity: 1V rms; overload protection: 550V DC or AC peak (no more than 10 seconds)  

Frequency measurement 

1. Insert the test leads or shielded cable into the 

COM

  and 

V/

Ω

/Hz

  jacks; 

2. Turn the range switch to the 

Hz

  position and connect the test leads or cables across the signal source or the load under test. 

Note: 

1) When the input exceeds 10Vrms, it can be read, but the error may be larger; 

2) In a noisy environment, it is best to use a shielded cable when measuring small signals; 

3) When measuring high voltage circuits, special care should be taken to avoid electric shock; 

                    Accuracy 

Range 

                            6000counts 

                                Resolution 

10Hz 

±(

0.1%+3

 

0.01Hz 

100Hz 

0.1Hz 

1kHz 

    1Hz 

10kHZ 

  10Hz 

100kHz 

100Hz 

1MHz 

  1kHz 

10MHz 

10kHz 

Summary of Contents for 6000counts

Page 1: ...6000counts Pocket Clamp Digital Multimeter Instruction Manual...

Page 2: ...en measuring voltage do not input a limit voltage exceeding the effective value of DC 1000V or AC 750V 2 The voltage below 36V of the current file is a safe voltage when measuring AC voltage higher th...

Page 3: ...ng least significant digit to ensure accuracy Ambient temperature 23 5 relative humidity 75 calibration guarantee period from the date of manufacture for one year 2 2 Performance Note indicates that t...

Page 4: ...input value 3 The test pen is reliably contacted with the test point and the screen displays the measured voltage value When measuring the DC voltage display the red test pen is the voltage polarity o...

Page 5: ...e to the instrument circuit 3 When measuring high voltage circuits special care should be taken to avoid electric shock 4 After completing all measurement operations please disconnect the test leads f...

Page 6: ...position trigger the SELECT key and select the resistance file to automatically measure Note 1 When measuring low resistance the test leads will bring internal resistance To obtain accurate reading y...

Page 7: ...e tested The reading is an approximation of the forward voltage drop of the diode For a silicon PN junction it is typically about 500mV 800mV is confirmed as normal value if the diode under test is op...

Page 8: ...ting the capacitor capacity to prevent damage to the fuse and meter 4 Unit 1F 1000mF 1mF 1000uF 1uF 1000nF 1nF 1000pF 3 7 Frequency measurement Input sensitivity 1V rms overload protection 550V DC or...

Page 9: ...two inputs of the device under test into the V Hz and COM terminals of the red test pen 3 Trigger the SELECT button The V Hz and COM terminals of the table respectively output 50Hz 100Hz 200Hz 300Hz 4...

Page 10: ...ndow 6 COM input negative input insert black test pen 7 Voltage resistance diode capacitor frequency square wave output current input port 8 HOLD is the data hold button long press for 2 seconds for t...

Page 11: ...method Not shown Battery not connected Replace the battery Low battery symbol Replace the battery Current is not input Replace fuse Resistance display error The test pen is not in contact This manual...