TABLE 2: HUMIDISTAT ACCESSORIES                                                                                                                     

H50

Internal humidity sensor for H200 humidistat and for H80 remote wall sensor.

H60

Duct humidity sensor to mount directly onto the back of any H200 humidistat.

H71

Duct humidity sensor to mount directly onto the supply or return of the ventilation duct.

H80

Wall humidity sensor to mount in any remote location.

H263

Programming tool for troubleshooting, viewing and modifying humidistat parameters.

008-0089

Replacement lexan (cover sticker) for H200 humidistat.

024-0048

Humidistat replacement base with connector (H50 internal humidity sensor not included).

H50   INTERNAL SENSOR

H60 DUCT SENSOR

H71   REMOTE DUCT SENSOR

This humidity sensor can be
mounted directly on 024-0048
humidistat base.

This humidity sensor can be
mounted directly onto the back of
any H200 humidistat, with the
supplied hardware. This
transforms the humidistat into a
duct-mounted humidistat.

This humidity sensor can be
mounted directly onto the supply
or return of the ventilation duct.
The H200 may be located on the
wall with humidity sensing from
the remote H71 sensor location.

H80   REMOTE WALL SENSOR

H263   PROGRAMMING TOOL

This humidity sensor can be wall
mounted in any remote location.
The humidistat may be located
on the duct or other location, with
humidity sensing from the H80
sensor location.

This tool is used to change
humidistat parameters.  It is also
useful for troubleshooting.  Just
plug it in the humidistat through
the casing.  See page 6 for more
details.

WARNING:

All H200 humidistats are
intended to control equipment
under normal operating
conditions.  Where failure or
malfunction of H200 series
humidistats could lead to an
abnormal operating condition
that could cause personal injury
or damage to the equipment or
other property, other devices
(limit or safety controls) or
systems (alarm or supervisory)
intended to warn of, or protect
against, failure or malfunction of
H200 humidistats must be
incorporated into and maintained
as part of the control system.

Summary of Contents for Micro-stat H200 Series

Page 1: ...page 5 for location Each humidistat is computer calibrated and factory programmed with default parameters All control parameters such as proportional band stage differential etc may be changed in the field with the H263 programming tool without having to remove the thermostat cover The H263 also doubles as a diagnostic tool and indicates the status of all the inputs and outputs and will reduce tro...

Page 2: ...y output and one relay dehumidify output Humidistat and sensor are duct mount Setpoint is user adjustable Resolution 0 5 for retransmit only See sensor specifications for dimensions of sensors Note the complete order code includes the sensor that will be shipped with the humidistat WIRING 2 ON OFF OUTPUTS Single transformer Fig 2 Wiring diagram with single transformer Multiple transformers Fig 3 W...

Page 3: ...o output 2 The humidity sensor is located in the return air duct Humidistat model number H200 69 13 10 Fig 6 Application example 6 COMMON N A INPUT MAIN SENSOR N A 10 Vdc 9 10 8 7 OUTPUT 1 TRANSMITTER 0 to 10 Vdc 0 to 5 Vdc OUTPUT 2 24 Vac 0 to 10 Vdc 4 5 3 24 Vac 2 1 FOR CONTROL HUMIDITY SENSOR RED BLACK WHITE DDC SYSTEM ELECTRONIC MOTOR or SCR or METER 6 COMMON N A N A INPUT MAIN SENSOR 10 Vdc 9...

Page 4: ...uct mounted humidistat This humidity sensor can be mounted directly onto the supply or return of the ventilation duct The H200 may be located on the wall with humidity sensing from the remote H71 sensor location H80 REMOTE WALL SENSOR H263 PROGRAMMING TOOL This humidity sensor can be wall mounted in any remote location The humidistat may be located on the duct or other location with humidity sensi...

Page 5: ...ol Code t1 0 On off 1 8 minutes 2 1 second Time 1 Time period for output no 1 t2 0 On off 1 8 minutes 2 1 second Time 2 Time period for output no 2 rA 0 C 1 F 1 DO NOT CHANGE Range Temperature Scale Ca 13 Calibration deviation mode DO NOT MODIFY USE AUTOCAL PROCEDURE FOR H100 TRANSMITTER USE THE ZERO POTENTIOMETER ON THE TRANSMITTER hA 0 à 127 Hardware assembly Code related to thermostat model and...

Page 6: ... 5 C to 50 C 32 F to 122 F Control 0 to 95 R H non condensing Sensor 0 to 100 R H see Note 1 Resolution 0 1 Repeatability 0 5 Accuracy and sensor interchangeability 2 R H from 0 to 100 R H Range 10 to 90 R H for 5 to 50 C 41 F to 122 F Temperature effect 0 05 F Outputs Isolated Triac 30 Vac at A max 0 to 5 VDC into 1KΩ resistance min 0 to 10 VDC into 2KΩ resistance min 0 5 VDC at 20 mA max for bot...

Reviews: