background image

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                                                              

VDR4-DVC

 

                                                              Keypad Controller

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

  

 

 

 

 

 

 

 

 

 

Vicon Industries Inc. does not warrant that the functions contained in this equipment will meet your

 

requirements or that the operation will be entirely error free or perform precisely as described in the

 

documentation. This system has not been designed to be used in life-critical situations and must

 

not be used for this purpose.

 

 

 

Warning: 

To prevent fire or shock hazard, do not expose the unit to rain or

 

moisture.

 

 

 

 

 

 

 

Copyright © 2009 Vicon Industries Inc. All rights reserved.

 

Product specifications subject to change without notice.

 

Vicon and its logo are registered trademarks of Vicon Industries Inc.

 

 

 

 

 

 

 

 

 

 

 

VICON INDUSTRIES LTD., BRUNEL WAY, FAREHAM, HAMPSHIRE, PO15 5TX, UK.

 

TEL: +44 (0)1489 566300  FAX: +44 (0)1489 566322

 

WEB: www.vicon-cctv.com

 

Summary of Contents for VDR4-DVC

Page 1: ...signed to be used in life critical situations and must not be used for this purpose Warning To prevent fire or shock hazard do not expose the unit to rain or moisture Copyright 2009 Vicon Industries Inc All rights reserved Product specifications subject to change without notice Vicon and its logo are registered trademarks of Vicon Industries Inc VICON INDUSTRIES LTD BRUNEL WAY FAREHAM HAMPSHIRE PO...

Page 2: ...w to select address 11 C Easy preset save and call 12 D How to use tour function 12 E How to use pattern function 12 F How to use scan function 13 G How to use AUX1 13 H How to use AUX2 14 I Easy function save and run 14 Access to the DVR menu 15 A Display selection 15 B DVR function 15 C Matrix function 16 How to use setup menu 18 Example of camera DVR setting operation 21 Specification 23 Dimens...

Page 3: ... presence of un insulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the product 3 CAUTION RISK OF ELECTRIC SHOCK DO...

Page 4: ...NERGY AND IF NOT INSTALLED AND USED IN ACCORDANCE WITH THE INSTRUCTION MANUAL MAY CAUSE HARMFUL INTERFERENCE TO RADIO COMMUNICATIONS OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXPENSE CAUTION CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPL...

Page 5: ...d for desktop operation and interface connectors are located in the junction box FEATURES To control all DVR functions such as Live display Playback DVR Setup PTZ and Matrix To control up to 255 DVRs from one keyboard controller To control up to 255 cameras from one keyboard controller Multi protocol supported PELCO D VICON Preset position control Maximum speed can be changed according to zoom rat...

Page 6: ...1 Junction box 1 8P RJ45 Modular Cable 2m 1 1 Jump 6 DVR 5 CAM1 C AM2 2 Junction Box 3 To Key Board 4 Key Board inside box 1 Jumper setting 2 Junction box 3 Junction box data In Out port To Keyboard 4 Keyboard data In Out port To Junction Box 5 Master RS485 D D To CAM1 CAM2 6 Slave RS485 D D To DVR 6 ...

Page 7: ... on the starting mode 4 Connect DVR RS485 D RS485 D to the Junction box terminal and the RS 485 A port of DVR Please make sure of the polarity 5 Connect Daisy out port of DVR to the Monitor DVR_ID 1 CAM 1 CAM 16 Daisy Out Juntion Box MONITOR UKB 400 RS 485 RS 485 A A port of RS 485 con M UL TI Z O O M L O C K S E Q F R Z 1 3 1 4 1 0 0 9 1 5 1 1 R E C PO WE R AL AR M 1 6 1 2 5 6 2 1 7 3 8 4 R PL AY...

Page 8: ... to DVR that DVR_ID number is 2 6 Connect Daisy out port of the last DVR to the Monitor DVR_ID 1 DVR_ID m CAM 1 CAM n n maximum 255 m maximum 255 Daisy Out Daisy In Daisy Out Juntion Box MONITOR UKB 400 Camera number n is different from DVR ID number m RS 485 RS 485 A A port of RS 485 con A A port of RS 485 con M UL TI Z O O M L O C K S E Q F R Z 1 3 1 4 1 0 0 9 1 5 1 1 R E C PO WE R AL AR M 1 6 1...

Page 9: ...14 MULTI A I Selection button for Screen Division of DVR or Camera Auto Iris key 15 ENTER Enter key 16 SEL Selects Key DVR and Key Board setting mode 17 ZOOM TELE Camera Zoom Control for Tele 18 ZOOM WIDE Camera Zoom Control for Wide 19 FOCUS NEAR Camera focus Control for Near 20 FOCUS FAR Camera focus Control for Far 21 IRIS OPEN Camera Iris Control for Open 22 IRIS CLOSE Camera Iris Control for ...

Page 10: ...PART NAME FUNCTION B PART NAME FUNCTIONS REAR SIDE Data out port Connector to communication and power ⓐ C DRAWING OF CONSOLE DESK 10 30mm 90mm 365mm 30mm 155mm ⓐ DATA ...

Page 11: ...1 255 3 Show the selected baud rate 2400 4800 9600 bps 4 Show the controller status B How to select address B 1 How to select address number 1 or 2 of camera or Up to 255 B 2 How to select address number 1 or 2 of DVR or Up to 255 11 Cam 001 2400 BPS Standby 1 2 3 4 1 CAM DVR 2 Cam 001 2400 BPS Standby Cam 001 2400 BPS Standby 2 1 Dvr 001 9600 BPS Standby Dvr 001 9600 BPS Standby ...

Page 12: ...has be to be set by using camera setup Menu 2 Generally Vicon tour function works by using specific preset number 80 87 3 After camera tour setup you can operate tour function calling preset number Up to 87 D 2 Using Pelco D protocol in case of Cam1 2400 bps 1 Tour has to be set by using camera setup Menu 2 pushing no 1 or 2 push TOUR shortly it makes TOUR work or Up to 8 12 1 2 1 2 PRST 8 0 PRST ...

Page 13: ... can operate pattern function calling preset number Up to 89 E 2 Using Pelco D protocol in case of Cam1 2400 bps 1 Pattern has to be set by using the camera setup Menu 2 Push number 1 or 2 push PTRN shortly it makes PTRN work or Up to 8 F How to use SCAN function F 1 How to use auto scan G How to use AUX1 function G 1 How to use AUX1 13 Cam 001 2400 BPS Î Scan SCAN A P Cam 001 2400 BPS Î Aux1 ZOOM...

Page 14: ... preset number It is inconvenient Function key saves camera number and preset number I 1 How to save function 1 999 In case that you save preset 1 of camera 1 at function1 first you have to operate preset 1 of camera 1 After that push number 1 and hold FUNC key for about 2 seconds Up to 999 I 2 How to run function 1 999 After pushing no 1 push FUNC key shortly it makes FUNC work Up to 999 14 Cam 0...

Page 15: ...ive mode Selection of Screen Division for Live Viewing mode 4 8 9 16 screen divisions Playback mode Selection of Screen Division for playback It shows 4 9 16 divided screen It works same as MULTI key of DVR B DVR Function In case of DVR 1 9600 bps B 1 How to use REC button Press once to begin recording all active channels Press again to end recording B 2 How to use SEARCH button Press once to open...

Page 16: ...t playback setup of a selected DVR menu Under PTZ control menu it can be used for increasing the speed of Pan Tilt Zoom Focus B 5 How to use PAUSE button Press once to freeze playback Press again to restart playback B 6 How to use STOP button Press once to stop playback B 7 How to use ZOOM button Zoom In Out on the images during Live Viewing 16 R PLAY Dvr 001 9600 BPS Î R PLAY PLAY Dvr 001 9600 BP...

Page 17: ... is changed into Cam mode and it waits camera control command Daisy chain output displays n channel camera image n channel camera is calculated by below formula n DVR_ID 1 16 camera channel number DVR ID 1 255 Ex Three sets of 16channel DVRs are installed You want to control the third camera of second DVR In this case n is calculated 2 DVR_ID 1 16 3 CAMERA CHANNEL 19 Daisy chain output displays th...

Page 18: ...d Rate You can change the value of Master baud rate by moving Joystick Left and Right A 4 How to change Slave Baud Rate You can change the value of Slave baud rate by moving Joystick Left and Right A 5 How to change Protocol You can change the Protocol by moving Joystick Left and Right TPro201 includes Pelco D You need Pelco D you can use TPro201 18 1 Baud Rate 1 Master 2400 BPS 2 Baud Rate 2 Slav...

Page 19: ...key When you forget the password please call to the vendors that you purchased from Up to999 Up to 999 A 8 Beep How to set beep You can change the beep On Off by moving Joystick Left and Right A 9 Function Use You can choose whether use or not the FUNC key Function Key is useful when you control several cameras You can save camera ID preset number at the specific function number 1 999 19 5 Passwor...

Page 20: ...ght How to set up LCD Backlight You can change the Always ON After 10sec After 20sec After 30sec After 60sec by moving Joystick Left and Right A 10 How to save and exit by Joystick Left and Right A 11 Exit 20 9 Save And Exit 10 Exit 8 LCD Backlight Always ON ...

Page 21: ...Baud rate 1 Master 2400 in case protocol is TPro201 1 Baud rate 1 Master 4800 in case protocol is VICON B 3 DVR control Baud rate 2 Baud rate 2 Slave 9600 B 4 Protocol 3 Protocol TPro 201 Same as PELCO D VICON B 5 Exit after saving the setting value 9 Save and Exit C Keyboard operation There is DVR mode and Camera model on Keyboard Change DVR mode DVR ID DVR button Change Camera mode CAMERA ID CAM...

Page 22: ...Speed dome camera 1 1 Plug in optional Daisy chain cable into extension port on No 1 No 2 DVR 1 2 Connect Daisy chain cable Vd_out on No 1 DVR into Daisy chain cable Vd_in on No 2 DVR 1 3 Connect Daisy chain cable Vd_out on No 2 DVR into monitor Matrix output screen 1 4 Set 1 on No 1 DVR ID and set 2 on No 2 DVR ID 1 5 Set 1 16 on No 1 DVR that is connected with Speed Dome camera ID and set 17 32 ...

Page 23: ... IN OUT available Joystick Power Consumption DC 12V 110mA Display Type 16 x 2 Character LCD With Blue Backlight Key Type PC Key board Button Key board Connector Type RJ45 8 Pin Modular Cable Junction Box Connector Master Terminal Block Slave Terminal Block Humidity 10 70 non Condensing Dimension 140 W x 185 H x 365 D Weight 1 2kg DIMENSION 23 Nov 2008 Rev 1 0 ...

Page 24: ...Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium Telephone 32 27128780 Fax 32 27128781 Spain Vicon Industries Molina de Segura 3 Local 4 28030 Madrid Spain Telephone 34 91 301 61 42 Fax 34 91 773 35 25 Italy Vicon Industries Via Sardegna 25 20060 Vignate Milano Italy Telephone 39 02 95938250 Fax 39 02 95938251 Germany vin videotronic infosystems gmbh Lahnstrasse 1 D 24539 Neumuenster ...

Reviews: