![Vicon VC566DN Installation & Operation Manual Download Page 7](http://html1.mh-extra.com/html/vicon/vc566dn/vc566dn_installation-and-operation-manual_1012790007.webp)
③
Autoiris lens connector for DC or VIDEO drive lens
This connector supplies 9 VDC power and video signal without sync, for video-drive type
autoiris lens.
Caution:
1. Only use AC 24V UL listed class2 power transformer.
2.
To prevent fire or shock hazard, UL listed wire VW-1, style 1007, should be used for
the cable for AC 24V input terminal.
PIN Signal
1
2
3
GROUND
POWER SUPPLY (9 VDC, 40mA)
VIDEO OUTPUT (0.7Vp-p without sync)
④
Autoiris lens connector for DC drive lens
This connector supplies the control signals to the DC drive autoiris lens.
⑤
Power indicator LED
This LED turns ON only when power is supplied properly and the DC-DC converter (or
the regulator) inside the camera works well.
⑥
ALC level adjustment potentiometer for DC drive lens
This potentiometer is used only if the camera is fitted with a DC drive autoiris lens. It is
used to control the amount of light striking the CCD image sensor.
XX135-10-01 Rev 409 VC566DN Cameras