1.  Installation of the camera must be performed by qualified service personnel in accordance 

with all local and national electrical and mechanical codes. 

2.  Do not attempt to disassemble the camera. 

In order to prevent electric shock, do not remove screws or cover. There are no 

user-serviceable parts inside. 

3.  Handle the camera with care. 

The camera could be damaged by improper handling or storage 

4.  Do not expose the camera to rain or moisture, or try to operate it in wet areas. Take 

immediate action if the camera becomes wet. Turn the power off and refer servicing to 

qualified service personnel. Moisture can damage the camera and also create a danger of 

electric shock. 

5.  Do not use strong or abrasive detergents when cleaning the camera body. 

Use a dry cloth to clean the camera when dirty. In a case where the dirt is hard to remove, 

use a mild detergent and wipe gently. 

6.  Never point the camera toward the sun. 

Whether the camera is used outdoors or not, never point it toward the sun. Use caution 

when operating the camera in the vicinity of spot lights or other bright lights and light 

reflecting objects. 

7.  Do not operate the camera beyond its temperature, humidity or power source ratings. 

Do not use the camera in an extreme environment where high temperature or high 

humidity exists. Use the camera under conditions where temperatures are between 

14°F~122°F (-10°C~+50°C), and humidity is below 85%. For the correct power supply, 

refer to the specification sheet. 

8.  If using AC 24V power adapter, only use the AC 24V UL Listed Class 2 power 

transformer. 

9.  Only use a Listed Class 2 power source. 

 

Caution: 

     

To prevent fire or shock hazard, the UL listed wire VW-1, style 1007, should be used for the 

cable. 

PRECAUTIONS  

 

XX135-10-01 Rev 409 VC566DN Cameras 

Summary of Contents for VC566DN

Page 1: ...d in life critical situations and must not be used for this purpose Copyright 2009 Vicon Industries Inc All rights reserved Product specifications subject to change without notice Vicon and its logo are registered trademarks of Vicon Industries Inc VICON INDUSTRIES INC 89 ARKAY DRIVE HAUPPAUGE NEW YORK 11788 TEL 631 952 CCTV 2288 FAX 631 951 CCTV 2288 TOLL FREE 800 645 9116 24 Hour Technical Suppo...

Page 2: ......

Page 3: ... of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a reside...

Page 4: ...he camera when dirty In a case where the dirt is hard to remove use a mild detergent and wipe gently 6 Never point the camera toward the sun Whether the camera is used outdoors or not never point it toward the sun Use caution when operating the camera in the vicinity of spot lights or other bright lights and light reflecting objects 7 Do not operate the camera beyond its temperature humidity or po...

Page 5: ...PACKING LIST 1 Iris lens connector plug for DC drive 1pc 2 C Mount lens adapter ring 1pc 3 Dust protective cap 1pc 4 Manual 1pc XX135 10 01 Rev 409 VC566DN Cameras 3 ...

Page 6: ...utput connector BNC 1 0Vp p 75Ω composite video signal is provided at this connector Power input connector screw terminal This terminal accepts 24 VAC power source Recommended Power Supply Minimum 300mA or 7 2W 4 XX135 10 01 Rev 409 VC566DN Cameras ...

Page 7: ...R SUPPLY 9 VDC 40mA VIDEO OUTPUT 0 7Vp p without sync Autoiris lens connector for DC drive lens This connector supplies the control signals to the DC drive autoiris lens Power indicator LED This LED turns ON only when power is supplied properly and the DC DC converter or the regulator inside the camera works well ALC level adjustment potentiometer for DC drive lens This potentiometer is used only ...

Page 8: ...r or white subject on the monitor 3 Adjust the screen color to be white pushing AWB HOLD push button 8 MODE SELECT SWITCH 1 INT LL switch This camera can operate independently using its internal crystal controlled sync generator or it may be synchronized using line locking To select one or the other of these sync modes set the DIP switch on the rear panel to either INT or LL Pole 1 is set to ON fo...

Page 9: ...ic light control mode Pole 4 is set to ON for EE ELC and OFF for AI ALC In the EE ELC mode a continuously variable electronic shutter is employed to automatically control the exposure time of the CCD image sensor according to the incoming light level With this mode selected a fixed or manual iris lens can be used instead of an autoiris lens In the AI ALC mode the CCD shutter speed is fixed to 1 60...

Page 10: ...ns is installed 5 AWB ATW select switch This camera has AUTO WHITE BALANCE ATW and MANUAL WHITE BALANCE AWB function The camera is automatically adjusted to the best condition in the ATW mode In the AWB mode it can be adjusted for the best color manually by pushing the AWB HOLD button 7 Pole 5 is set to ON for ATW and OFF for AWB 6 AGC ON OFF switch This switch is provided for the AGC circuit The ...

Page 11: ...s A and B are connected to a power supply with the same polarity To make an adjustment follow the steps below 1 While observing the video output signals from both cameras on an oscilloscope press camera A s V phase control push button on back of camera until vertical sync from both cameras is in phase 2 If camera A s adjustment range is insufficient adjust camera B s V phase control push button in...

Page 12: ...nses 1 Install a lens and connect the camera to a monitor and power supply as described in this manual 2 Open the iris completely If an autoiris lens used reduce the room lighting to allow the lens to open completely This gives the most accurate results 3 Adjust the screw slowly until the sharpest picture is obtained This completes the adjustment The backfocus adjustment screw is held in place by ...

Page 13: ... lens using the remote lens control 5 Adjust the backfocus screw for the sharpest image 6 Zoom out to the maximum wide angle setting If the picture is no longer in focus readjust the backfocus screw 7 Repeat steps 4 6 until the image remains sharp through the entire zoom range This completes the adjustment The backfocus adjustment screw is held in place by friction so there is no locking screw XX1...

Page 14: ...1 Simplest One monitor system with one camera EXAMPLES OF CONNECTIONS 1 Simplest One monitor system with one camera 2 One monitor system with two or more cameras 12 XX135 10 01 Rev 409 VC566DN Cameras ...

Page 15: ... Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Name and address of the company returning the unit b Name of the Vicon employee who issued the R A c R A number d Brief description of the installation e Complete description of the problem and circumstances under which it occurs f Unit s original date...

Page 16: ...nce and better video quality with increased difficulty in handling and installation Let the required picture quality and cable distance provide a guide in choosing the best cable type For cables other than the approved Vicon types below contact the manufacturers listed below Note that BC refers to bare copper and TC refers to tinned copper Recommended Coaxial Cable Types Cable Type Belden Type No ...

Page 17: ...O MORE THAN 48dB AGC OFF NIGHT 0 0009 FC 0 01 LUX AT 25IRE F1 2 LENS MIN ILLUMINATION DAY 0 05 FC 0 5 LUX AT 25IRE F1 2 LENS ELECTRONIC IRIS 1 60 1 100 000 SEC 1 50 1 100 000 SEC AUTO WHITE BALANCE 2 500 K 7 500 K LINE LOCK RANGE 60Hz 1 0Hz 50Hz 1 0Hz BACK LIGHT COMPENSATION CENTER WEIGHTED ZONE EXTERNAL CONTROLS z INT LL SELECT z BLC ON OFF z ALC ELC SELECT z AWB ATW SELECT z AGC ON OFF z DAY NIG...

Page 18: ...E POWER REQUIREMENT 24VAC 20 400 MAX FULL ISOLATION OPERATING CONDITION 14º F TO 122º F 10º C 50º C WITH 85 RH NET WEIGHT WITHOUT LENS APPROX 0 84 lb 380 g DIMENSIONS W x H x D 2 4 in x 2 0 in x 5 0 in 60 mm x 50 mm x 126 5 mm 16 XX135 10 01 Rev 409 VC566DN Cameras ...

Page 19: ...DIMENSIONS VICON P D S DAY XX135 10 01 Rev 409 VC566DN Cameras 17 ...

Page 20: ...rs Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Germany vin videotronic infosystems gmbh Lahnstrasse 1 D 24539 Neumuenster Phone 49 0 4321 8790 Fax 49 0 4321 879 47 Far East Office Unit 5 17 F Metropole Square 2 On Yiu Street Shatin New Territories Hong Kong 852 2145 7118 Fax 852 2145 7117 Internet Address www vicon cctv com ...