Installing & Adjusting Camera 

Select a location that is clear of obstacles and can support the weight of the unit.  Exercise maximum caution 
when installing the unit to the wall or ceiling the unit falling can result in injuries and accidents. It is recommended 
to install the camera 2-4 meters from the floor. As a failsafe against falling, attach the unit by chain, wire cable 
or other safety restraint to an appropriate anchor point. 
 
The infrared laser will turn on in the low light conditions and 5 tiny red dots will be visible. Do not look directly 
at the lens of the camera as it may impair eyesight. 
 
Step 1: Prepare the mounting holes 
 
To provide for cable management, the camera can be mounted to a back box, model V940B-BOX. 
 
Note: Make sure there is room for a cable routing hole at the location and drill a hole to route the cables. 
Cabling should be routed to the installation location.   
 
The V940B-BOX consists of two pieces (bottom and cover) and is supplied with a mounting template and 
hardware necessary to mount it. Using the mounting template, prepare the three mounting holes. Secure the 
bottom of the box to the surface using the screws and anchors supplied or hardware appropriate for the 
mounting surface. There are three cable access holes provided, one on the side and two on the rear. Route the 
cables through one of these access holes.   
 
 
 
 
 
 
 
 
 
 
 
 
Step 2: Install the camera 
Route the cables from the camera through the cable access hole in the cover. Insert the slit in the white foam 
plug onto the cable assembly from the camera and insert the plug into the cable access hole in the cover. 
Route the camera cable assembly through the metal cable plate provided and secure this entire assembly onto 
the back box cover with screws provided.   
 
Secure the camera to the back box cover in the circle inset using the screws and washers provided in the 
accessory kit. Align the standoffs in the bottom with the holes in the cover and secure the cover/camera 
assembly to the bottom of the back box. 

 

 

 

Cable access holes (3X) 

Standoffs for camera 
mounting (4X) 

Mounting holes (3X) 

Cable access hole 

Insert cables from camera. 
Secure with foam plug and 
metal plate provided. 

Summary of Contents for V940B

Page 1: ...be used in life critical situations and must not be used for this purpose Document Number 8009 8291 20 03 Product specifications subject to change without notice Issued 6 18 Copyright 2018 Vicon Indus...

Page 2: ...he following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation FCC INFOR...

Page 3: ...commended by manufacturer Position power source and related wires to assure to be kept away from ground and entrance Refer to qualified personnel for all service matters Save product packaging to ensu...

Page 4: ...ut All cameras use H 265 H 264 M JPEG encoding providing output with excellent definition and color reproduction more detailed and accurate information and the accuracy of smart analysis that can effe...

Page 5: ...o not point the camera lens directly toward the sun or other strong light Do not install the camera in environments with temperature beyond the acceptable range 40 F to 140 F 40 C to 60 C or with high...

Page 6: ...modular jack Power Standard adapter jack for 12 VDC or 24 VAC Alarm In Alarm input and output 5 pin terminal GND Alarm Out Alarm COM Audio In Audio input 2 pin terminal line level microphone GND Audio...

Page 7: ...template and hardware necessary to mount it Using the mounting template prepare the three mounting holes Secure the bottom of the box to the surface using the screws and anchors supplied or hardware a...

Page 8: ...ing Alarms There are two dry contact alarm inputs and one alarm output provided the alarm output acts as a switch to drive an external device such as a light Refer to the figures below for connection...

Page 9: ...ted try to reset the hardware of the camera Follow up steps below to process To reset the hardware to connect the Alarm1 Alarm2 and Alarm Ground together while the camera is on as shown in the picture...

Page 10: ...wser for the camera is Internet Explorer Depending on the version of Windows and IE your screens may be slightly different but similar in function Connect the network camera to the network and power u...

Page 11: ...low the prompts Live View interface displaying the major stream at H 264 format Click the Settings tab and select Network On this page below select Off to turn off DHCP Then enter the required IP addr...

Page 12: ...settings can only be set in the Live view settings interface when they are enabled in the Audio Video Settings Click the option tab Settings to enter the system Settings interface From the Settings t...

Page 13: ...am2 For third stream rtsp IP ch1 stream3 The RTSP stream is accessed through the following links when Allowed anonymity is turned off For major stream rtsp ADMIN password IP ch1 stream1 For minor stre...

Page 14: ...VICON INDUSTRIES INC For office locations visit the website www vicon security com...

Reviews: