background image

 VICON

INSTRUCTIONS FOR
INSTALLATION AND OPERATION

MODEL 

 FIXED MINI DOME

1. INTRODUCTION

The information in this manual covers the installation
and maintenance of the 

 Fixed-Ceiling 

can. Read these instructions through completely before

performing any installation procedures.

This unit should be installed by a qualified technician
using approved materials and wiring practices in accord-
ance with national, state, and local wiring codes.

The 

 Omniscan is designed to accommodate

small monochrome and color solid-state cameras for

installations where discreet surveillance is a necessity.
This unit is designed to be mounted in a drop ceiling,

although it may be installed in other types of ceilings.

A mounting rail option (Model 

 is available

for installations requiring additional support, and a steel

ceiling panel option (Model 

 is available to

replace the existing ceiling tile.

The viewing dome of the 

 is tinted neutral gray

overall, and the interior surface is painted flat black,

except for a narrow viewing strip. The combination of
tinted plastic and the painted interior makes it virtually
impossible to see into the dome. Attached by clips and
nuts, the dome is easily removed to simplify installation
and service.

2. INSTALLATION

2.1 Unpacking and Inspection

 equipment is tested and inspected before leaving

the factory. It is the carrier’s responsibility to deliver the
equipment in the same condition as it left the factory.

2.1.1 INSPECTION FOR VISIBLE DAMAGE

Immediately inspect the cartons upon delivery. Make a
note of any visible damage on all copies of the carrier’s
freight bill.

2.1.2 INSPECTION FOR CONCEALED
DAMAGE

As soon as possible after delivery, unpack the unit and
inspect it for concealed damage. Do not discard the carton
or packing materials. If the unit is damaged, contact the
carrier immediately and request forms for filing a damage
claim. Make arrangements for a representative of the
carrier to inspect the damaged equipment.

Make sure the carrier’s agent (the person making the
delivery) signs the note on all copies of the bill. If the agent
does not have claim forms, contact the carrier’s office.

If the equipment must be returned for repair, follow the
Shipping Instructions at the end of this manual.

WARNING: TO PREVENT RISK OF FIRE OR ELECTRICAL SHOCK, DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE.

Product specifications subject to change without notice.

Vicon part number 8006-8851-00-00

Copyright   1998 Vicon Industries Inc. All rights reserved.

Vicon and its logo are registered trademarks of Vicon Industries Inc.

VICON INDUSTRIES INC. 

89 ARKAY DRIVE, HAUPPAUGE, 

N.Y. 

11788 

TEL: 

 

 

FAX: 

 

TOLL FREE: 

l-800-645-91 16 

UK: 

 

INFOFAX: l-800-287-1207 

WORLD WIDE WEB: 

Summary of Contents for V7FCD

Page 1: ...on All Vicon equipment is tested and inspected before leaving the factory It is the carrier s responsibility to deliver the equipment in the same condition as it left the factory 2 1 1 INSPECTION FOR VISIBLE DAMAGE Immediately inspect the cartons upon delivery Make a note of any visible damage on all copies of the carrier s freight bill 2 1 2 INSPECTION FOR CONCEALED DAMAGE As soon as possible aft...

Page 2: ...ding type plug 12 Power Cord Protection Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them payin convenience receptacles an 8 particular attention to cords at plugs product the pointwhere theyexitfrom thevideo 13 0utdoorCableCrounding Ifanoutsidecablesystem isconnected to the video product be sure the cable system is grou...

Page 3: ...ith Existing Tile CAUTION The ceiling tile used in this procedure A must be strong enough to support the combined weight of the V7FCD and the camera lens assembly Although the V7FCD is not heavy upper housing anddome have a combined weight of 6 9 lb 3 1 kg refer to appropriate product specifications for the weightsofthe cameraandlens manytypesofceiling tile have little tensile strength so special ...

Page 4: ...ws provided Screws should be inserted downwards from the ceiling 2 3 3 Installation Using the V3380MR Mounting Rail Kit The V3380MR mounting rail kit may be used in con junction with either an existing ceiling tile or the V7FCP ceiling panel option If an existing ceiling tile is to be used cut a circular opening in the tile as described in Section 2 3 1 and set the tile aside 1 2 3 Find four 4 sup...

Page 5: ...crews and washers Loosen the nuts on the clips on the underside of the trim ring and slip the dome flange into the clips Refer to Figure 3 Attach the dome to the trim ring by tightening the nuts Verify that the lens clears the dome by l 4 inch 0 64 cm 6 Rotate the lower dome until the scene as viewed on the monitor is completely visible through the tinted viewing strip of the dome Reinstall the tr...

Page 6: ...o prevent removal of paint Again after waxing re move dust or lint with clean dry air CAUTION A Excessive pressure or rubbing on the dome s surface can cause permanent scratches that may render the dome unusable 6 Cleaning of the outer surface is accomplished with any nonabrasive cleaning cloth and cleaning agent that is safe for use on acrylic plastic Either liquid or spray cleaner wax suitable f...

Page 7: ...a Name and address of the company return ing the unit b Name of the Vicon employee who issued the R A C R A number d Brief description of the installation e Complete description of the problem and circumstances under which it occurs For service or returns from countries in Europe contact f Unit s original date of purchase if still under Warranty VICON INDUSTRIES U K LTD 3 Pack the unit carefully U...