background image

- iv -

1.

  

Read these instructions.

2.

  

Keep these instructions.

3.

  

Heed all warnings.

4 .

 

Follow all instructions.

5.

  

Do not use this apparatus near water.

6.

  

Clean only with dry cloth.

7.

  

Do not block any ventilation openings. Install in accordance with the 

     manufacturer's instructions.

8.

  

Do not install near any heat sources such as radiators, heat registers, 

     stoves, or other apparatus (including amplifiers) that produce heat.

9.

  

Do not defeat the safety purpose of the polarized or grounding-type 

     plug. A polarized plug has two blades with one wider than the other. 

     A grounding type plug has two blades and a third grounding prong. 

     The wide blade or the third prong are provided for your safety. If the 

     provided plug does not fit into your outlet, consult an electrician for 

     replacement of the obsolete outlet.

10.Protect the power cord from being walked on or pinched particularly 

     at plugs, convenience receptacles, and the point where they exit from 

     the apparatus.

11. Only use attachments/accessories specified by the manufacturer.

12. Use only with the cart, stand, tripod, bracket, 

      or table specified by the manufacturer, 

      or sold with the apparatus. 

      When a cart is used,use caution when moving 

      the cart/apparatus combination to avoid injury 

      from tip-over.

13. Unplug this apparatus during lightning storms or when unused for 

       long periods of time.

14. Refer all servicing to qualified service personnel. Servicing is 

      required when the apparatus has been damaged in any way, such as

      power-supply cord or plug is damaged, liquid has been moisture, does 

      not operate normally, or has been dropped.

15. CAUTION  THESE SERVICING INSTRUCTIONS ARE FOR USE BY 

      QUALIFIED SERVICE PERSONNEL ONLY. TO REDUCE THE RISK 

      OF ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING OTHER 

      THAN THAT CONTAINED IN THE OPERATING INSTRUCTIONS 

      UNLESS YOU QRE QUALIFIED TO DO SO.

16. Use satisfy clause 2.5 of IEC60950-1/UL60950-1 or Certified/Listed 

      Class 2 power source only.

IMPORTANT SAFETY INSTRUCTIONS

Summary of Contents for V660B-488IR

Page 1: ...ecisely as described in the documentation This system has not been designed to be used in life critical situations and must not be used for this purpose Vicon Industries Inc 89 Arkay Drive Hauppauge N...

Page 2: ...oulet if it is not going to be used for several days or more To disconnect the cord pull it out by the plug Never pull the cord itself Allow adequate air circulation to prevent internal heat build up...

Page 3: ...FERENCE TO RADIO COMMUNICATIONS OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN...

Page 4: ...ugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table s...

Page 5: ...to and manual white balance modes DWDR OSD Font Color 16 Color BLC Back Light Compensation Day Night Auto DAY NIGHT EXT Private Mask 8 position 16 Colors AGC Auto Gain Control MIRROR ON OFF VIDEO OUT...

Page 6: ...e area monitoring 2 Power 24V AC input 12V DC input power source from a DC 12V or AC 24V ac 10 60 50Hz 1Hz Use Certified Listed Class 2 power source only If using DC 12V power adaptor use a power supp...

Page 7: ...ont of the housing Leave the screws intact Fig 1 2 Drill the mounting location using the supplied drill guide label Fig 3 3 Attach the housing to the ceiling using suitable fasteners M6x35 tapping scr...

Page 8: ...unted on a 4 x 4 or 4 x 2 electrical box MOUNTING HOUSING TO AN ELECTRICAL BACK BOX Electrical box Rubber Washers 4x Video out check Test Monitor Joystick Switch Board S P O T V I E O D CN2 R G I H T...

Page 9: ...5 0 1 in 3 0mm thick impact resistant P C LEXAN 3 9in 9 9cm diameter Unit mm inches 1 89 Ib 0 86Kg 2 33 Ib 1 06Kg 115 4 3 59 2 3 56 4 2 2 146 4 5 7 R49 5 1 9 17 5 0 6...

Page 10: ...ally impossible to see any details of the subjects Adjusts the iris so that a distinctive subject and the background are delivered at the same time HLC High Light Compensation When a high brightness s...

Page 11: ...ction and compensation function can automatically detect and compensate up to 64 white pixels with the highest detection level in sequence so as to maintain the image quality MIRROR Reverses the image...

Page 12: ...SHUTTER BRIGHTNESS AGC DWDR RETURN WHITE BAL DAY NIGHT AUTO COLOR B W EXT SPECIAL CAM TITLE MOTION PRIVACY PARK LINE LANGUAGE RETURN IMAGE ADJUST LENS SHAD 2 DNR MIRROR FONT COLOR CONTRAST SHARPNESS...

Page 13: ...OSURE menu is used to set the automatic light control method for this camera Xtended Dynamic Range 1 SHUTTER Select the shutter mode Auto 1 60 50 FLK 1 100 000 sec Can be changed while in shutter mode...

Page 14: ...r temperature to 3200 K o OUTDOOR Set the color temperature to 6300 K BACKLIGHT BLC AREA SEL AREA1 AREA STARE ON GAIN IIIIIIIIIIIIIIIIII042 IIIIIIIIIIIIIIIIII HEIGHT 005 WIDTH IIIIIIIIIIIIIIIIII004 LE...

Page 15: ...uto setting Dead pixels are automatically removed DPC COVER THE LENS THEN PRESS ENTER KEY PROCESSING NOW ATW1 AUTO LENS EXPOSURE WHITE BAL BACKLIGHT DAY NIGHT DPC SPECIAL IMAGE ADJ RESET EXIT ATW1 AUT...

Page 16: ...e selected area the pink dots are displayed on the screen A CAM TITLE B Character Table C Command Line Move to left Move to right CLR Erase all characters POS Move the position of title END Save and E...

Page 17: ...ANGUAGE ENGLISH or CHINESE 6 RETURN RET PRIVACY AREA SELECT AREA1 ON AREA STATE HEIGHT IIIIIIIIIIIIIIIIII 032 WIDTH IIIIIIIIIIIIIIIIII 032 LEFT RIGHT IIIIIIIIIIIIIIIIII 020 IIIIIIIIIIIIIIIIII TOP BOTT...

Page 18: ...SHAD 2DNR MIRROR FONT COLOR CONTRAST SHARPNESS DISPLAY NEG IMAGE RETURN IIIIIIIIIIIIIIIIII 122 IIIIIIIIIIIIIIIIII 21 ON ON OFF IMAGE ADJUST OFF CRT IMAGE ADJUST 1 LENS SHAD Adjust Lens shading level 0...

Page 19: ...IIIIIIIIIII 192 RETURN RET LENS SHAD 2DNR MIRROR FONT COLOR CONTRAST SHARPNESS DISPLAY NEG IMAGE RETURN IIIIIIIIIIIIIIIIII 122 IIIIIIIIIIIIIIIIII 21 ON ON OFF IMAGE ADJUST OFF CRT LCD AJUST GAMMA 0 50...

Page 20: ...T to Wide W field of View Focus Adjust lens focus from near N to infinity DC AUTO IRIS LENS Image Size 1 3 CCD Focal Length Aperture Ratio Angular Field of View 2 8 12mm DIAGONAL o 2 8mm 119 9 o 12mm...

Page 21: ...Shading OFF LOW MIDDLE HIGH FACTORY RESET RETURN Lens Mount External Dimension Weight BNC connector 146 x 115 H mm AC24V 10 DC12V 10 860g Electronic Shutter 1 60 1 100 000 sec 1 50 1 100 000 sec Video...

Page 22: ...policy The Company will not be obligated to repair or replace equipment showing abuse or damage or to parts which in the judgment of the Company are not defective or any equipment which may have been...

Page 23: ...Headquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Vicon Germany Kornstieg 3 D 24537 Neumuenster Phone 49 0 4321 8790 Fax 49 0 4321 879 97 Far East Office U...