background image

 

4

Programming Function 

 
All programming is done with the front panel keys. There are thirteen keys on the front panel. The key named 

MENU, 1/ , 2/ , 3/ , 4/ , 

and 

QUAD/ENTER

 are used in programming units

 

The 

TITLE, VCR, ALM, ZOOM, FRZ,

 

PIP 

and

 SEQ

 keys are not used in programming the unit. Functions of 

each key on the front panel are described in Table 1. 

 Scrolls upward through program selections ; selects entries. 
 Scrolls downward through program selections ; selects entries. 

Enter or set function 

Press the 

MENU

 key to display the programming screen. The following is displayed: 

 
 

 
 
 
 
 
 
 
 
 
 
 

 
 

5.1 

Time/Date 

 

This menu allows you to setup the time and date of the video display and the quad screen. 

Select 

TIME/DATE 

on the Main Menu and press Enter key. The following menu is displayed: 

 
 
 
 
 
 
 
 
 
 
 
 
 

5.1.1  

Time Format 

 

Select 

TIME FORMAT

 and press the Enter key. The following menu is displayed: 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

MAIN MENU 

(1) TIME/DATE 
(2) CAMERA    SETUP 
(3) ALARM     SETUP 
(4) RECORD  SETUP 
(5) DISPLAY    FORMAT 
(6) EVENT  LOG 
(7) PASSWORD SET  
(8) EXIT 

 

 

TIME /DATE 

(1) TIME   

  FORMAT 

(2) DATE   

  FORMAT 

(3) TIME/DATE  SET 
(4) EXIT 

 

 

TIME FORMAT 

 

12 HOURS ( AM / PM ) 

 

 
 
 
  TO EXIT PRESS (ENTER) KEY.

 

Summary of Contents for V5400MUX

Page 1: ...roduct specifications subject to change without notice Vicon and its logo are registered trademarks of Vicon Industries Inc VICON INDUSTRIES INC 89 ARKAY DRIVE HAUPPAUGE NEW YORK 11788 TEL 631 952 CCTV 2288 FAX 631 951 CCTV 2288 TOLL FREE 800 645 9116 24 Hour Technical Support 800 34 VICON 800 348 4266 UK 44 0 1489 566300 INFOFAX 800 287 1207 WEB www vicon cctv com ...

Page 2: ......

Page 3: ......

Page 4: ...ment off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the equipment with respect to the receiver Relocate the equipment away from the receiver Plug the equipment into a different electrical outlet so that the equipment and receiver are on different branch circuits If necessary the user should cons...

Page 5: ... not use attachments not recommended by Vicon as they may cause hazards 7 Water and Moisture Do not use this video product in any location where it may be exposed to water or moisture This does not apply to outdoor camera housings outdoor pan and tilt drives and other equipment designed for direct exposure to outdoor environments 8 Accessories Do not place this video product on any unstable surfac...

Page 6: ...cords as this can result in a risk of fire or electric shock 17 Object and Liquid Entry Never push objects of any kind into this video product through openings as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock Never spill liquid of any kind on the video product 18 Servicing Do not attempt to service this video product yourself as opening or...

Page 7: ......

Page 8: ...8 5 3 4 Video Loss Alert 8 5 3 5 Buzzer Out 8 5 3 6 Relay Out 8 5 4 Record Setup 9 5 4 1 Record Time Setup 9 5 4 2 Field Delay 9 5 4 3 Record Mode Setup 10 5 4 4 Alarm Record Setup 10 5 4 5 Alarm Speed Setup 10 5 4 6 VCR Input 10 5 5 Display Setup 10 5 5 1 PIP Mode Setup 11 5 5 2 Color Setup 11 5 5 3 Border Line 12 5 5 4 Display Position Setup 12 5 5 5 Time Display Setup 12 5 5 6 Title Display Set...

Page 9: ...of four camera inputs combined with numerous additional functions Each quadrant may be sequenced full screen or be displayed in a quad split The image display is updated at the field rate of 60 field sec p roviding genuine real time video In addition to the quad screen and PIP Picture In Picture display the units offer VCR ZOOM playback function to allow full screen viewing during tape playback No...

Page 10: ... Picture switching function NONE SEQ Selects the sequential switching function NONE 1 Selects camera 1 for full screen display on monitor Scrolls upward through program selections selects entries 2 Selects camera 2 for full screen display on monitor Scrolls downward through program selections selects entries 3 Selects camera 3 for full screen display on monitor Shifts cursor to the left in menus s...

Page 11: ...s selects entries Enter or set function l Press the MENU key to display the programming screen The following is displayed 5 1 Time Date This menu allows you to setup the time and date of the video display and the quad screen l Select TIME DATE on the Main Menu and press Enter key The following menu is displayed 5 1 1 Time Format l Select TIME FORMAT and press the Enter key The following menu is di...

Page 12: ... menu is displayed l Press the 1 or 2 key to toggle and select the required format The options are MM DD YEAR DD MM YEAR YEAR MM DD l Press the Enter key 5 1 3 Time Date Setup l Select TIME DATE SET and press the Enter key The following menu is displayed TIME FORMAT 24 HOURS 0000 2359 TO EXIT PRESS ENTER KEY DATE FORMAT MM DD YEAR TO EXIT PRESS ENTER KEY TIME DATE SET MM DD YEAR HH MM SS 05 03 200...

Page 13: ...ss the Enter key The following menu is displayed l Press the 1 and 2 keys to move the cursor to required channel l Using the 3 and 4 keys to select the character position and the1 and 2 keys to select the character select the camera title up to a max of 8 character Choose from the following for each of the characters Number 0 9 Alphabet 26 letters Special Characters l Select EXIT and press the Ent...

Page 14: ...generated l Select ALARM DWELL and press the enter key The following menu is displayed l Press the 1 or 2 keys to adjust the time The options are 1 60 SEC automatic reset period HOLD alarm continues until the alarmed camera key is pressed followed by the ALM key FOLLOW alarm continues on during the period of input and will go off automatically l Press the enter key to exit the menu ALARM SETUP 1 A...

Page 15: ...s the Enter key The following menu is displayed l Press the 1 or 2 key to select channel l Press Enter key to toggle ON and OFF l Select EXIT and press the Enter key to exit the menu 5 3 5 Buzzer Out The BUZZER OUT function allows you to enable or disable an audible alarm l Select BUZZER OUT on the ALARM SETUP screen by pressing1 or 2 key ON or OFF is highlighted l Press the Enter key to toggle th...

Page 16: ... when the video output of the unit is connected to the VCR to be recorded l Select FIELD DELAY from the RECORD SETUP screen Field Delay is only applicable when the REC MODE is set as TIME LAPSEmode l Press the Enter key to toggle the options The options are VEXT USED 001 FIELD Number of field is selectable from 001 to 511field l Press 3 and 4 keys or Enter key to changes the number of field l Sele...

Page 17: ... ALM SPEED on the RECORD SETUP screen and press Enter key l Press Enter key to toggle the options and then 3 or 4 key to adjust the speed The options are FRAME REC R T Recording in frame with real time speed FIELD REC R T Recording in field with real time speed FOLLOW Recording with the speed already set in REC MODE menu 1 361Field Select a time delay for the time lapse recording l Select EXIT and...

Page 18: ...it the menu 5 5 2 Color Setup You can adjust the color brightness and contrast for each individual camera input for optimum display l Select COLOR ADJUST on the DISPLAY SETUP screen The following menu is displayed l Select the camera 1 4 by pressing the 1 key l Select Brightness or Contrast by pressing the 2 key l Control brightness of camera by the 3 key and 4 key l Control contrast of camera by ...

Page 19: ...he Enter key to toggle ON or OFF to display or delete the time display on monitor The options are ON display the time display on monitor OFF delete the time display on monitor l Select EXIT and press the Enter key to exit the menu 5 5 6 Title Display Setup l Select TITLE DISPLAY on the DISPLAY SETUP menu l Press the Enter key to toggle ON or OFF to display or delete the title display on monitor Th...

Page 20: ...LE 5 7 1 Set the Password The unit incorporates a password function for entry to the menu operation This ensures that only authorized persons can change the unit s settings l Select PASSWORD setting as ENABLE and then select NEW PASSWORD on the PASSWORD SETTING menu l Press the Enter key to set the password The following menu is displayed l Enter a Password of 4 digits Confirm the same password ag...

Page 21: ...e menu status screen will be turned to Normal Quad status and will be continued in sequence mode PIP Display Mode When the PIP key is selected the screen will be displayed as PIP status as programmed on the PIP MODE SETUP menu The selected channel for the PIP display changes in order REC View Mode At normal display mode the screen will be turned to show recording status by pressing Title VCR keys ...

Page 22: ... 232 Commands Signal format is as follows 1 Data Format 1 200 Baud 8 Data Bit No Parity One Stop Bit 2 Mode Half Duplex Mode Not Echo Received Character RS232 pinout Pin 1 Not used Pin 2 Receive Pin 3 4 Not used Pin 5 Common Pin 6 9 Not used Table RS 232 Commands COMMAND RS 232 CODE Title TI VCR input VR Rec View RV Alarm AM Menu MU Zoom ZO PIP PI FRZ FR Down DN Left LF Right RG SEQ SG Enter ET Nu...

Page 23: ...stries Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Name and address of the company returning the unit b Name of the Vicon employee who issued the R A c R A number d Brief description of the installation e Complete description of the problem and circumstances under which it occurs f...

Page 24: ...Europe Headquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium 322 712 8780 Fax 322 712 8781 Vicon China Unit 5 17 F Metropole Square 8 On Yiu Street Shatin New Territories Hong Kong 852 2145 7118 Fax 852 2145 7117 Internet Address www vicon cctv com ...

Reviews: