background image

 

X458 Rev 700 V1101C 

Important Safeguards  

••

  iii 

Important 
Safeguards 

GRAPHIC SYMBOL EXPLANATION 

 

The lightning flash with arrowhead symbol, within an 
equilateral triangle, is intended to alert the user to the 
presence of uninsulated “dangerous voltage” within 
the product’s enclosure that may be of sufficient 
magnitude to constitute a risk of electric shock. 

 
The exclamation point within an equilateral triangle is 
intended to alert the user to the presence of important 
operating and maintenance (servicing) instructions in 
the literature accompanying the unit. 
 

1. Read Instructions  -

 All the safety and operating 

instructions should be read before the video product is 
operated. 
 

2. Retain  Instructions  -

 All the safety and operating 

instructions should be retained for future reference. 
 

3. Heed Warnings -

 All warnings on the video product 

and in the operating instructions should be adhered to. 
 

4. Follow Instructions  -

 All operating and use 

instructions should be followed. 
 

5. Cleaning -

 Step 

a

 applies to equipment that can be 

disconnected from the CCTV system without seriously 
jeopardizing security. Step 

applies to equipment that 

must operate continuously such as video switching 
equipment at military installations. 
 

a.  Disconnect this video product from its power 

source before cleaning. Do not use caustic, 
abrasive, or aerosol cleaners. Use a damp cloth 
for cleaning. 

b.  Use a damp cloth to clean the equipment. Do not 

allow moisture or liquids to enter any vents. Do not 
use caustic, abrasive, or aerosol cleaners. 

 

6. Attachments  -

 Do not use attachments not 

recommended by Vicon as they may cause hazards. 
 

7. Water and Moisture -

 Do not use this video product 

in any location where it may be exposed  to water or 
moisture. This does not apply to outdoor camera 
housings, outdoor pan-and-tilt drives, and other 
equipment designed for direct exposure to outdoor 
environments. 
 

8. Accessories  -

 Do not place this video product on 

any unstable surface or table. The video product may 
fall, causing serious injury to a person and serious 
damage to the video product.  Use only with a mounting 
accessory recommended by Vicon, or sold with the video 
product. Any mounting of the video product should 
follow Vicon’s instructions, and a mounting accessory 
recommended by Vicon should be used.  
 

9. Ventilation  -

 Slots and openings in the cabinet are 

provided for ventilation and to ensure reliable operation 
of the video product and to protect it from overheating, 
and these openings must not be blocked or covered. 
The openings should never be blocked by placing the 
video product on a rug or other similar surface. This 
video product should never be placed near or over a 
radiator or heat register. This video product should not 
be placed in a built-in installation such as a bookcase 
or rack unless proper ventilation is provided or Vicon’s 
instructions have been adhered to. 
 

10. Power Sources  -

 This video product should be 

operated only from the type of power source indicated 
on the marking label. If you are not sure of the type of 
power supplied to your installation site, consult your 
Vicon dealer or local power company. For video 
products intended to operate from battery power, or 
other sources, refer to the operating instructions.  
 

11. Grounding  -

 This applies to video products 

equipped with a 3-wire grounding-type plug, a plug 
having a third (grounding) pin. This plug only fits into a 
grounding-type power outlet. This is a safety feature. If 
you are unable to insert the plug into the outlet, contact 
your electrician to replace your obsolete outlet. Do not 
defeat the safety purpose of the grounding-type plug. 
 

12. Power-Cord Protection  -

 Power supply cords 

should be routed so that they are not likely to be 
walked on or pinched by ite ms placed upon or against 

 

Summary of Contents for V1101C

Page 1: ...ice Vicon and its logo are registered trademarks of Vicon Industries Inc WARNING TO PREVENT RISK OF FIRE OR ELECTRICAL SHOCK DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE VICON INDUSTRIES INC 89 ARKAY DRIVE HAUPPAUGE NEW YORK 11788 TEL 631 952 CCTV 2288 FAX 631 951 CCTV 2288 TOLL FREE 800 645 9116 24 Hour Technical Support 800 34 VICON 800 348 4266 UK 44 0 1489 566300 INFOFAX 800 287 1207 WEB www vi...

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ...spection For Concealed Damage 3 Wiring the Unit 3 Wiring the Pan and Tilt 3 Wiring the Motorized Lens 4 Wiring the Housing 4 Testing and Adjustment Procedures 5 For All Adjustments 5 Output Voltage Selection 5 Housing Controls 6 Operation 7 Power 7 Pan and Tilt 7 Lens 7 Maintenance 8 Shipping Instructions 8 Technical Information 9 ...

Page 6: ......

Page 7: ...an and tilt drives and other equipment designed for direct exposure to outdoor environments 8 Accessories Do not place this video product on any unstable surface or table The video product may fall causing serious injury to a person and serious damage to the video product Use only with a mounting accessoryrecommended by Vicon or sold with the video product Any mounting of the video product should ...

Page 8: ...t in a fire or electric shock Never spill liquid of any kind on the video product 18 Servicing Do not attempt to service this video product yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified service personnel 19 Damage Requiring Service Disconnect this video product from its power source and refer servicing to qualified serv...

Page 9: ...e attempting installation The V1101C is a multifunction unit that controls pan and tilt drives lens functions and housing accessories The unit features the P TPAD multiposition front panel disc for manual control of pan and tilt functions and an autopan control switch for automatic operation Operating controls including zoom f ocus iris and speed comprise the manual lens drive functions The V1101C...

Page 10: ...2 Introduction X458 Rev 700 V1101C Notes ...

Page 11: ...rms for filing a damage claim Make arrangements for a representative of the carrier to inspect the damaged equipment If the equipment must be returned for repair follow the Shipping Instructions at the end of this manual Wiring the Unit Each V1101C Control is supplied with a complete set of mating connectors for housing pan and tilt and lens control Fabricate interconnecting cables according to th...

Page 12: ...d Copper Maximum Distance for Voltge ft m Low Medium High 22 900 270 2100 640 3300 1000 20 1400 430 3300 1000 5300 1600 18 2300 700 5400 1650 8400 2600 Figure 3 Lens Interconnection Diagram Wiring the Housing Prepare the interconnecting cable assembly for the housing according to Figure 4 Select the wire size from Table 2 Table 2 Housing Operating Distances Cable Size AWG Maximum Distance to Contr...

Page 13: ...iously selected and press the ZOOM IN push button to enlarge the image of the distant object in the field of view Pressing ZOOM OUT causes a much larger portion of the scene to be included in the monitor image producing a wide angle effect 5 Operate the IRIS OPEN push button The scene viewed on the monitor becomes lighter Then press the IRIS CLOSE push button The scene becomes darker Output Voltag...

Page 14: ...ure 5 Lower Housing Retaining Screw Location Housing Controls The CAM camera switch controls the power to the camera Press once for power on press again for power off The WIPR wiper switch turns the window wiper accessory on or off The WSHR washer accessory is designed to direct a small high pressure stream of water at the window To obtain the best washing action turn the wiper on first Operate th...

Page 15: ...to have priority over the autopan function it is not necessary to place the control in the manual mode if the operator wishes to momentarily interrupt autopan operation Lens Operating controls and their corresponding functions are listed in Table 3 All controls except for the output voltage switch are located on the front panel To access the output voltage switch follow the instructions under Outp...

Page 16: ...r service or returns from countries in Europe contact Vicon Industries U K Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Name and address of the company returning the unit b Name of the Vicon employee who issued the R A c R A number d Brief description of the installation e Complete ...

Page 17: ...or an installation Output Voltage Pan and Tilt 24 VAC Lens 2 8 VDC Housing 24 VAC Line Cord Standard three conductor SV No 18 AWG cable with grounding plug Fuse 120 VAC 3 A 3 AG 230 VAC 1 5 A 3 AG Cable Requirements Pan and Tilt 8 conductor unshielded Lens 5 conductor shielded Housing 6 conductor unshielded Connectors P T output Vicon part no 1806 5003 07 Mating connector supplied Lens output Vico...

Page 18: ...ton OPEN CLOSE Speed knob control Iris response three position switch low medium high internal Output voltage three position switch slow medium fast internal Pan and Tilt Functions Pan and tilt multiposition disc Autopan push button on off latching switch Power Indicator LED MECHANICAL Overall Dimensions max Height 3 13 in 79 5 mm Width 10 0 in 254 mm Depth 8 in 203 mm Weight 4 5 lb 2 0 kg Constru...