34
•
Technical Information
XX163-17-00 Rev 1208 SVFT-PRS Pressurized Dome Housing
Technical Information
ELECTRICAL
Drive Type:
Electrical motorized pan and tilt, electronic control.
Camera Types:
Units available in color and day/night (NTSC/PAL) formats
and a variety of zoom and feature capabilities.
Input Voltage:
18-30 VAC. (Will operate within spec on voltages up to 32
VAC. For voltages between 30-32 VAC, a Class 3 indoor/dry
or outdoor/wet power supply with appropriate wiring methods
in accordance with the National Electrical Code ANSI/NFPA
70, State and Local wiring codes must be used.)
Maximum Wire Distance for Power Cable:
See Table 4.
Table 4
Maximum Power Cable Distance
Current:
1.8 A with SurveyorVFT (coax, UTP, fiber).
2.3 A (ViconNet).
Power:
44 W with SurveyorVFT (coax, UTP, fiber).
54 W (ViconNet).
Heat Equivalent:
2.5 btu/min (0.6 kg-cal/min) with SurveyorVFT (coax, UTP,
fiber); 3.1 btu/min (0.77 kg-cal/min) (ViconNet).
Note: These figures represent the conversion of 100% of the electrical energy to heat. Actual percentage of
the heat generated will be less and will vary from product to product. These figures are provided as an
aid in determining the extent of cooling required for an installation.
Video Output Impedance:
75
ohms.
Fuse:
F1: 5 x 20 mm, 1.6 A 250 VAC, slo-blo.
F2: 5 x 20 mm, 2.5 A 250 VAC, slo-blo.
Radio Frequency Emission Rating:
FCC Class A.
Distance ft (m)
24 VAC
28 VAC
Wire Size
(AWG)
Annealed
Copper Wire
Coax, Fiber,
UTP
ViconNet
Coax, Fiber,
UTP
ViconNet
20
165 (65)
130 (40)
280 (85)
217 (66)
18
258 (102)
203 (62)
438 (134)
340 (104)
16
413 (126)
325 (99)
700 (213)
544 (169)
14
660 (262)
520 (159)
1120 (341)
870 (265)
12
1031 (314)
812 (248)
1750 (533)
1359 (414)