Vicon SurveyorVFT Quick Manual Download Page 19

 

Alarm Handling —

 Configures the SurveyorVFT’s four alarm inputs. 

Relay Driver —

 Adjusts and configures the relay output for control of external devices. 

Source Titling —

 Programs and displays the various titles available to the SurveyorVFT.  

Note: All titles are disabled from the factory and will not be displayed upon initial startup. 

Preset/Tour Handling —

 Programs preset events into the camera dome. It also allows 

programming a series of events or

 

actions into a script called a Tour and

 

Autotour and on 

23X/35X versions, Motion Detection zone set up. 

Scheduler/Time of Day —

 The Scheduler provides a means of programming events to occur at 

specific times of the day. The Time of Day feature allows programming of the time display 
format. It allows selection of daylight saving time, 12/24-hour format and actual setting of the 
time and date. 

Language —

 Programs language format for titles and menus. Language choices are English, 

Spanish, French, German and Italian. The word “Language” will continuously change between 
the five translated words, Language, Idioma, Langue, Sprache and Lingua, to alert an operator 
that this prompt is related to changing the language. When selected, the menus will immediately 
display the new language. 

Install Defaults —

 Resets the SurveyorVFT to the factory default settings. All previously 

programmed titles and settings are lost when this function is accessed, so keep a record of 
programmed settings. The main default settings are listed in the Install Defaults section. Some 
default settings are camera dependent; those are not listed.  

Note: On unit power up, when DIP switch SW2 positions 2, 6, 7 and 8 are all set to ON, the unit will perform 

an Install Defaults. 

 

Pressurization 

Pressurizing the Housing Assembly (SVFT-PRS) 

1.  Reattach the previously removed service cover to the service opening using the four (4) captive screws. 
2.  Using a regulated source of dry Nitrogen gas with the proper Schraeder type fill fitting, as shown in 

Figure below, regulate the gas pressure to 10.0 psi (0.68 atm or bars). 

3.  Attach the fill fitting to the housing assembly’s fill valve located at the lower side of the housing and 

pressurize the housing assembly. When the relief valve opens (gas will hiss from the top of the relief 
valve), allow this to purge for a minimum of 5 minutes to assure that all the enclosed air is replaced by 
nitrogen; then remove the fill fitting. The relief valve is rated at 5 psi +/- 0.5 psi (0.34 atm or bars +/- 
0.03 atm or bars). Monitor the actual pressure for the next hour. If, in one hour the pressure has not 
dropped below 4.5 psi (0.31 atm or bars), it is assumed that the housing assembly is sealed and the 
relief valve is seating properly. 

4.  Reinstall the cap on the fill valve.  

Caution: Pressurizing the housing assembly beyond 10 psi, or with an unregulated gas source, can 

cause severe injury to personnel and permanent damage to the assembly. When connecting 
a gas source to the housing for pressurization and initial purging, it is critical to ensure the 
gas source is regulated to a maximum of 10 psi. Failure to regulate the inlet pressure to this 
value can result in an over pressure condition, which can result in a housing failure. This 
could potentially lead to personal injury and damage to the housing. 

 

Summary of Contents for SurveyorVFT

Page 1: ...your requirements or that the operation will be entirely error free or perform precisely as described in the documentation This system has not been designed to be used in life critical situations and...

Page 2: ...onal Electrical Code ANSI NFPA 70 1984 provides information on proper grounding of the lead in wire to an antenna discharge unit size of grounding conductors and the requirements of grounding electrod...

Page 3: ...series includes 23X and 36X models 2 Standard PTZ SurveyorVFT Indoor Pendant SVFT P series includes 23X and 36X models 3 Standard PTZ SurveyorVFT Outdoor Pendant SVFT W series includes 23X and 36X mo...

Page 4: ...Quick Installation Standard PTZ In Ceiling Model...

Page 5: ...Quick Installation Standard PTZ Indoor Pendant...

Page 6: ...Quick Installation Standard PTZ Outdoor Pendant...

Page 7: ...Quick Installation SVFT M Impact Resistant...

Page 8: ...Quick Installation SVFT PRS Pressurized Pressurize the housing with Dry Nitrogen gas according to the procedure in this manual Reinstall cap on fill valve Reinstall service cover...

Page 9: ...Quick Installation Fixed In Ceiling Access to Ceiling...

Page 10: ...Quick Installation Fixed In Ceiling No Access to Ceiling...

Page 11: ...Quick Installation Fixed Indoor Pendant...

Page 12: ...Quick Installation Fixed Outdoor Pendant...

Page 13: ...rveyorVFT and SVFT M J2 for optional fiber optics interface board that provides video and RS 422 full duplex data through a standard fiber optics connector Wiring Connections Standard Coaxial Fiber Op...

Page 14: ...ns ViconNet Version Pin Connections SVFT PRS Prefabricated cable On coaxial and UTP units L M X and U are not used On fiber units L M J K X and U are not used On ViconNet units A C D P T L M J K X and...

Page 15: ...video an ST connector for fiber optic or an RJ 45 connector on the ViconNet board for video connection and a removable two position screw terminal connector for camera power DIP Switch Settings The ad...

Page 16: ...sectors 97 Initiate Dome reset 98 Autopan limits 99 Set manual pan limits Presets are usually solved at the maximum speed typically less than 1 second if a preset is assigned to a tour or salvo the p...

Page 17: ...Auto baud detect functions after installing defaults using preset 95 when switching Vicoax to Pilot NOVA VPS and upon power up when the dome sees an incorrect baud rate from keypad or control system I...

Page 18: ...le indefinitely To clear the autopan limits Store preset 98 Press AUX 2 and AUX 3 without panning to set the autopan limits to the same position By recording both limits on the same point they will bo...

Page 19: ...mera dependent those are not listed Note On unit power up when DIP switch SW2 positions 2 6 7 and 8 are all set to ON the unit will perform an Install Defaults Pressurization Pressurizing the Housing...

Page 20: ...an 2 psi per year Note The housing with mechanism has approximately 490 in 3 of volume Note The pressurized function has not been evaluated by UL Warning Do not use any gas type other than dry Nitroge...

Page 21: ...ature applications in that it directs warm air onto the lower bubble surface minimizing icing and foggingIcondensation problems Its installation is shown pictorially in the figures below The duct snap...

Page 22: ...1 minimum is required to be able to access this mode which should be installed in conjunction with installing the duct This firmware enables you to run the heater fan at max speed at low temperature...

Page 23: ...been authorized for return by the Company and the return shipment is prepaid in accordance with policy Repaired or replacement hardware will be warranted for the remainder of the original Warranty Per...

Page 24: ...all not exceed the price paid for the product These limitations on potential liabilities have been an essential condition in setting the product No one is authorized to assume any liability on behalf...

Page 25: ...Vicon Industries Inc For office locations visit the website www vicon security com...

Reviews: