Vicon SurveyorVFT Quick Manual Download Page 17

 

Preset 88-89 (Autotour Sequences)

 — An Autotour is a series of up to 256 pan, tilt and zoom actions

.

 

Accessing the “Program Autotour” option will bring up an on-screen menu which allows dynamic 
programming of each autotour event. This is described in greater detail in the Preset/Tour Handling menu 
section. 

Preset 90 (Pan/Tilt Lockout)

 — Storing preset 90 will disable joystick control of that dome, and the 

message Pan/Tilt Disabled will momentarily appear on the screen. Any time the joystick is moved, the 
message will reappear. To restore pan/tilt operation, preset 90 must be stored again. 

This feature prevents the camera dome’s position from being tampered with. This allows the dome to 
respond only to preset positions, eliminating the operator’s ability to manually position the dome. It also 
allows a unit to be temporarily locked onto a subject for recording or monitoring specific activity. Recalling 
preset 90 has no effect. The camera dome retains its capability of zoom, focus and iris control while 
locked. 

Preset 93 (Set Response Line Polarity)

 (Duplex Only) — The SurveyorVFT checks for polarity of the 

command in lines through the auto baud detect feature. The baud detect cycles through 4800+/4800-
/9600+/9600-/19200+/19200-, indicating not only the baud rate it is searching for but also the polarity that 
the receive lines are set to. When preset 93 is selected, the dome will periodically cycle the polarity of the 
COMM IN+ and COMM IN- lines. During the cycling, pan the joystick and press either the A/I or A/P key. 
As soon as one of the respective lights illuminates, press the AUX2 key. This locks in the correct polarity 
for operation. 

Preset 94 (Enter Dome Menu System)

 — Many SurveyorVFT features are accessed through a series of 

on-screen menus. These are described in the following programming menu sections and accessed by 
storing preset 94. Recalling preset 94 has no effect. For convenience, when performing programming, 
pressing the L-SPD (lens speed) button will display a black background. 

Preset 95 (Auto-Baud Detect Feature)

 — Auto-baud detect functions after installing defaults, using 

preset 95, when switching Vicoax to Pilot/NOVA (VPS) and upon power-up when the dome sees an 
incorrect baud rate from keypad or control system. It allows the camera dome to detect a new baud rate 
from the host controller without having to fully reboot the camera dome and lose all stored configuration 
parameters. Be sure that auto home on power up is disabled before executing this command. Symbols 
are used to display the status of the detection process. The * symbol indicates that valid data at the 
correct baud rate has been received, the X symbol represents a framing error has been received and the 
- symbol indicates that no data has been received. Recalling preset 95 has no effect. 

Preset 96 (Program Dome Sectors)

 — The SurveyorVFT has the ability to divide its 360

°

 field-of-view 

into sections or sectors. There may be up to 16 sectors and the boundaries for each are programmed for 
each individual dome. An individual title may be programmed for each sector and video may be enabled 
or disabled. More information on disabling sector video or “sector censoring” and titling may be found in 
the Camera Controller and Source Titling menu sections. 

Storing preset 96 will begin the sector programming process by establishing the left boundary for sector 
1. Pan the camera to the right and press the 

AP

 (autopan) key to set the right boundary for sector 1, 

which is also the left boundary of sector 2. Continue panning the camera and pressing 

AP

 until all 16 

boundaries have been programmed. If fewer than 16 sectors are required, press 

AP

 repeatedly at the 

right boundary of the last sector you will be programming to use up all the boundary numbers and exit 
sector-programming mode. 

When the camera is moved, the corresponding sector title is displayed on the screen (when sector titles 
have been enabled). If the video is disabled for a given sector, a black screen with the words “Blank 
Sector” will appear when the camera enters that sector and video will be restored when the camera 
moves to a sector where video is enabled. Sector programming can be aborted by issuing a preset recall; 
this will also erase any prior sector programming. Recalling preset 96 has no effect. 

Summary of Contents for SurveyorVFT

Page 1: ...your requirements or that the operation will be entirely error free or perform precisely as described in the documentation This system has not been designed to be used in life critical situations and...

Page 2: ...onal Electrical Code ANSI NFPA 70 1984 provides information on proper grounding of the lead in wire to an antenna discharge unit size of grounding conductors and the requirements of grounding electrod...

Page 3: ...series includes 23X and 36X models 2 Standard PTZ SurveyorVFT Indoor Pendant SVFT P series includes 23X and 36X models 3 Standard PTZ SurveyorVFT Outdoor Pendant SVFT W series includes 23X and 36X mo...

Page 4: ...Quick Installation Standard PTZ In Ceiling Model...

Page 5: ...Quick Installation Standard PTZ Indoor Pendant...

Page 6: ...Quick Installation Standard PTZ Outdoor Pendant...

Page 7: ...Quick Installation SVFT M Impact Resistant...

Page 8: ...Quick Installation SVFT PRS Pressurized Pressurize the housing with Dry Nitrogen gas according to the procedure in this manual Reinstall cap on fill valve Reinstall service cover...

Page 9: ...Quick Installation Fixed In Ceiling Access to Ceiling...

Page 10: ...Quick Installation Fixed In Ceiling No Access to Ceiling...

Page 11: ...Quick Installation Fixed Indoor Pendant...

Page 12: ...Quick Installation Fixed Outdoor Pendant...

Page 13: ...rveyorVFT and SVFT M J2 for optional fiber optics interface board that provides video and RS 422 full duplex data through a standard fiber optics connector Wiring Connections Standard Coaxial Fiber Op...

Page 14: ...ns ViconNet Version Pin Connections SVFT PRS Prefabricated cable On coaxial and UTP units L M X and U are not used On fiber units L M J K X and U are not used On ViconNet units A C D P T L M J K X and...

Page 15: ...video an ST connector for fiber optic or an RJ 45 connector on the ViconNet board for video connection and a removable two position screw terminal connector for camera power DIP Switch Settings The ad...

Page 16: ...sectors 97 Initiate Dome reset 98 Autopan limits 99 Set manual pan limits Presets are usually solved at the maximum speed typically less than 1 second if a preset is assigned to a tour or salvo the p...

Page 17: ...Auto baud detect functions after installing defaults using preset 95 when switching Vicoax to Pilot NOVA VPS and upon power up when the dome sees an incorrect baud rate from keypad or control system I...

Page 18: ...le indefinitely To clear the autopan limits Store preset 98 Press AUX 2 and AUX 3 without panning to set the autopan limits to the same position By recording both limits on the same point they will bo...

Page 19: ...mera dependent those are not listed Note On unit power up when DIP switch SW2 positions 2 6 7 and 8 are all set to ON the unit will perform an Install Defaults Pressurization Pressurizing the Housing...

Page 20: ...an 2 psi per year Note The housing with mechanism has approximately 490 in 3 of volume Note The pressurized function has not been evaluated by UL Warning Do not use any gas type other than dry Nitroge...

Page 21: ...ature applications in that it directs warm air onto the lower bubble surface minimizing icing and foggingIcondensation problems Its installation is shown pictorially in the figures below The duct snap...

Page 22: ...1 minimum is required to be able to access this mode which should be installed in conjunction with installing the duct This firmware enables you to run the heater fan at max speed at low temperature...

Page 23: ...been authorized for return by the Company and the return shipment is prepaid in accordance with policy Repaired or replacement hardware will be warranted for the remainder of the original Warranty Per...

Page 24: ...all not exceed the price paid for the product These limitations on potential liabilities have been an essential condition in setting the product No one is authorized to assume any liability on behalf...

Page 25: ...Vicon Industries Inc For office locations visit the website www vicon security com...

Reviews: