background image

XX151-02-00 Rev 1206 Surveyor4A Fixed-Position Camera Dome 

Reference  

  13 

Twisted-Pair Cable 

Caution:  Careful selection of the proper cable is essential to obtain the best performance from this 

equipment. Vicon assumes no responsibility for poor performance when cables other than 
those recommended are installed. 

 

Materials

 

 
Use a pure copper stranded or solid conductor with or without a tin plating to obtain a low DC resistance. Do not use cable 
with either steel or aluminum stranded conductor because these do not transfer signals effectively for long distances. The 
preferred insulation is Polyvinyl chloride (PVC). It has better electrical characteristics than polyethylene and resists flames, 
sunlight and most solvents, but is more vulnerable to moisture. 
 

Cable Types 

 
The most commonly used cable types are point-to-point unshielded twisted pair wire, stranded or solid, unjacketed,  
24 gauge or thicker. They can be category 2, 3, 4, or 5. The video signal may co-exist in the same wire bundle as other 
video, telephone, data, control signals or low-voltage power. It is also acceptable to run the signal adjacent to fluorescent 
lights or other power sources (in accordance with National Electrical Code, local and other safety requirements). Make 
sure the pair of wires carrying the video signal is sent as a twisted pair (the blue-white/white-blue wires twisted together as 
a pair), not a “split pair” (blue-white conductor, part of one pair/orange-white conductor, part of another pair). 
 
Choose a Belden or equivalent cable type by referring to the characteristics and maximum distances listed below. The 
characteristics of the cables in the Tables should be used as a guideline when cables other than Belden are used. 
Materials and construction must follow the guidelines above. 
 
Wire resistance may be measured with an ohmmeter by shorting the two conductors together at the far end and 
measuring the loop-resistance out and back. Compare your readings to the following chart. 

Wire Distances 

 

 

Wire Gauge AWG 

 

 

Distance 

ft 

(m) 

18 20 22 24 

250 (76) 

3

Ω

 

5

Ω

 

8

Ω

 13

Ω

 

315 (96) 

4

Ω

 

6

Ω

 10

Ω

 16

Ω

 

397 (121) 

5

Ω

 

8

Ω

 13

Ω

 21

Ω

 

500 (152) 

7

Ω

 10

Ω

 17

Ω

 26

Ω

 

630 (192) 

8

Ω

 13

Ω

 21

Ω

 33

Ω

 

794 (242) 

10

Ω

 16

Ω

 26

Ω

 41

Ω

 

1000 (305) 

13

Ω

 20

Ω

 33

Ω

 52

Ω

 

1260 (384) 

16

Ω

 25

Ω

 42

Ω

 66

Ω

 

1587 (484) 

21

Ω

 32

Ω

 52

Ω

 83

Ω

 

2000 (610) 

26

Ω

 40

Ω

 66

Ω

 104

Ω

 

Note: All quoted distance specifications include any coaxial cable in the run. It is recommended that the wire distance be 
measured to ensure that the capability of the product is correct. 

 

Recommended Unshielded Twisted-Pair Cable Type 

Cable Type

Wire Size 

(AWG)

Insulation Material Conductor Type

Resistance (ohms)

Number of 

Twisted Pairs

Belden1721X

24, Solid

Polyethylene

Bare Copper

100

1

 

Summary of Contents for SURVEYOR4A

Page 1: ...used in life critical situations and must not be used for this purpose WARNING To reduce a risk of fire or electric shock do not expose this product to rain or moisture Copyright 2005Vicon Industries...

Page 2: ......

Page 3: ...ent off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the equipment with respect to the receiver Re...

Page 4: ...unit 13 Outdoor Cable Grounding Use only grounded outdoor cables to protect against voltage surges and static charges Section 810 of the National Electrical Code ANSI NFPA 70 1984 provides information...

Page 5: ...lation 3 Unpacking and Inspection 3 Inspection for Visible Damage 3 Inspection for Concealed Damage 3 Surveyor4A Dome Components 3 Mounting the Unit 4 Camera Lens Adjustments 7 Final Installation 9 Op...

Page 6: ...iv Quick Installation XX151 02 00 Rev 1206 Surveyor4A Fixed Position Camera Dome Quick Installation...

Page 7: ...y night camera with a choice of fixed focal length or varifocal autoiris lenses A smoked lower dome is included A model is available that offers twisted pair video connection A UTP receiver is require...

Page 8: ...00 1 4 in high resolution day night color camera and 2 6 6 mm autoiris varifocal lens 24 VAC isolated power input 4 inch smoked lower dome NTSC coaxial cable video S4AVF DN C 8403 01 1 4 in high reso...

Page 9: ...amera dome units consist of an enclosure an adjustable camera mounting bracket a mask and a smoked lower dome It includes a 4 x 4 electrical box for cable routing and mounting The camera lens assembly...

Page 10: ...ling requirements Install a suitable strain relief or conduit fitting and route the cables through the connector and into the box 3 Compress the mounting bracket flush to the electrical box and insert...

Page 11: ...connections will cause damage to the unit 9 Connect the video cable male BNC to the pendant cable female BNC connector on the top of the enclosure ALTERNATE CONNECTION For the model using the twisted...

Page 12: ...con recommends several power supplies depending on the needs of the installation Refer to the table below For other multichannel power supplies contact Altronix Corporation at 888 258 7669 Model Numbe...

Page 13: ...that the performance of the camera s line lock depends on the quality of the power source If the camera experiences roll or jitter due to the quality of the power source then it is best to set the ca...

Page 14: ...is the end ring iris is fixed On autoiris lenses iris adjustment may be required if the picture appears dark or grainy or has poor color There is a potentiometer VR1 on the camera front board to adjus...

Page 15: ...he nut The picture may be squared up by rotating the camera about its own axis up to 360 roll adjustment Note After all adjustments are made be sure to tighten all bracket screws Final Installation Wh...

Page 16: ...dome s interior they should be removed with clean dry air pressure compressed air cans 3 If spots streaks or stains appear on the interior or exterior they can be removed with a solution of isopropyl...

Page 17: ...m countries in Europe contact Vicon Industries Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following infor...

Page 18: ...ing 95 or better coverage Cable Types The most commonly used cable types are RG 59 U and RG 11 U Each is actually a family of cables with widely varying electrical characteristics some of which are no...

Page 19: ...l and other safety requirements Make sure the pair of wires carrying the video signal is sent as a twisted pair the blue white white blue wires twisted together as a pair not a split pair blue white c...

Page 20: ...roduct These figures are provided as an aid in determining the extent of cooling required for an installation Maximum Operating Distance Wire Gauge AWG ft m 20 18 16 14 18 960 293 1500 457 2400 732 38...

Page 21: ...in 120 mm Total width of electrical box 4 75 in 121 mm Weight Approximately 2 25 lb 1 02 kg Construction Cast plastic aluminum and steel Finish Painted light gray smoked gray tint lower dome ENVIRONM...

Page 22: ...VF DN S4AVF DN C 1 4 CCD 2 1 interlace NTSC PAL Color Mono Color 550 Mono 580 Day 0 07 0 8 Night 0 009 0 1 at 40 IRE f 1 4 1 60 1 50 1 100 000 48 dB AGC off S4VFT 3312 1 3 ExView CCD 2 1 interlace NTS...

Page 23: ...ny equipment which may have been tampered with altered misused or been subject to unauthorized repair Software supplied either separately or in hardware is furnished on an As Is basis Vicon does not w...

Page 24: ...288 800 645 9116 Fax 631 951 CCTV 2288 Vicon Europe Headquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Germany vin videotronic infosystems gmbh Lahnstrasse 1...

Reviews: