background image

XX151-02-00 Rev 1206 Surveyor4A Fixed-Position Camera Dome 

Installation  

  5 

7.  Refer to the table in Technical Information for the maximum operating distances of Surveyor4A. The 

gauge of wire used determines this distance. 

8.  Strip approximately 1 in. (25 mm) of outer insulation off power cables. Then strip off approximately 1/4 in. 

(6 mm) of insulation off each individual wire. Attach the camera power cables to the screw terminal on the 
top of the enclosure according to the markings. The power supply for the camera must be 24 VAC. Refer 
to Figure 5. 

Note:  Vicon systems and components, like most electronic equipment, require a clean, stable power source. 

Voltage irregularities such as surges, drops, and interruptions can affect the operation of your 
equipment and, in severe cases, damage certain components. Vicon strongly recommends the use of 
line conditioners, voltage regulators, and uninterruptible power supply (UPS) systems. 

 

Caution: Be sure to make pin connections correctly. Wrong pin connections will cause damage to the unit. 

9.  Connect the video cable male BNC to the pendant cable female BNC connector on the top of the 

enclosure.

 ALTERNATE CONNECTION:

 For the model using the twisted-pair video connection, use the 

twisted-pair video wires as shown in Figure 5. Strip off approximately 0.25 in. (6 mm) of insulation from 
each individual wire. Attach each wire to the screw terminal on the top of the enclosure. This signal is 
polarized and specific wire connection is necessary. Follow the markings on the board for connections. 
Refer to the instructions supplied with the receiver for those connections. 

10.  Loosen the two (2) screws at the corners of the electrical box and line up the screw holes with the two (2) 

keyholes on the enclosure. Position the enclosure and attach it to the electrical box by lightly tightening 
the corner screws until the enclosure is secure.  

 

Note: Do not overtighten the corner screws; overtightening distorts the enclosure, making the installation of 

the lower dome difficult

.

 

11. Connect the safety cord (lanyard) on the lower dome to one of the holes provided in the enclosure with 

the screw that is provided. 

 

 

Figure 2 

Electrical Box Components 

Summary of Contents for SURVEYOR4A

Page 1: ...used in life critical situations and must not be used for this purpose WARNING To reduce a risk of fire or electric shock do not expose this product to rain or moisture Copyright 2005Vicon Industries...

Page 2: ......

Page 3: ...ent off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the equipment with respect to the receiver Re...

Page 4: ...unit 13 Outdoor Cable Grounding Use only grounded outdoor cables to protect against voltage surges and static charges Section 810 of the National Electrical Code ANSI NFPA 70 1984 provides information...

Page 5: ...lation 3 Unpacking and Inspection 3 Inspection for Visible Damage 3 Inspection for Concealed Damage 3 Surveyor4A Dome Components 3 Mounting the Unit 4 Camera Lens Adjustments 7 Final Installation 9 Op...

Page 6: ...iv Quick Installation XX151 02 00 Rev 1206 Surveyor4A Fixed Position Camera Dome Quick Installation...

Page 7: ...y night camera with a choice of fixed focal length or varifocal autoiris lenses A smoked lower dome is included A model is available that offers twisted pair video connection A UTP receiver is require...

Page 8: ...00 1 4 in high resolution day night color camera and 2 6 6 mm autoiris varifocal lens 24 VAC isolated power input 4 inch smoked lower dome NTSC coaxial cable video S4AVF DN C 8403 01 1 4 in high reso...

Page 9: ...amera dome units consist of an enclosure an adjustable camera mounting bracket a mask and a smoked lower dome It includes a 4 x 4 electrical box for cable routing and mounting The camera lens assembly...

Page 10: ...ling requirements Install a suitable strain relief or conduit fitting and route the cables through the connector and into the box 3 Compress the mounting bracket flush to the electrical box and insert...

Page 11: ...connections will cause damage to the unit 9 Connect the video cable male BNC to the pendant cable female BNC connector on the top of the enclosure ALTERNATE CONNECTION For the model using the twisted...

Page 12: ...con recommends several power supplies depending on the needs of the installation Refer to the table below For other multichannel power supplies contact Altronix Corporation at 888 258 7669 Model Numbe...

Page 13: ...that the performance of the camera s line lock depends on the quality of the power source If the camera experiences roll or jitter due to the quality of the power source then it is best to set the ca...

Page 14: ...is the end ring iris is fixed On autoiris lenses iris adjustment may be required if the picture appears dark or grainy or has poor color There is a potentiometer VR1 on the camera front board to adjus...

Page 15: ...he nut The picture may be squared up by rotating the camera about its own axis up to 360 roll adjustment Note After all adjustments are made be sure to tighten all bracket screws Final Installation Wh...

Page 16: ...dome s interior they should be removed with clean dry air pressure compressed air cans 3 If spots streaks or stains appear on the interior or exterior they can be removed with a solution of isopropyl...

Page 17: ...m countries in Europe contact Vicon Industries Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following infor...

Page 18: ...ing 95 or better coverage Cable Types The most commonly used cable types are RG 59 U and RG 11 U Each is actually a family of cables with widely varying electrical characteristics some of which are no...

Page 19: ...l and other safety requirements Make sure the pair of wires carrying the video signal is sent as a twisted pair the blue white white blue wires twisted together as a pair not a split pair blue white c...

Page 20: ...roduct These figures are provided as an aid in determining the extent of cooling required for an installation Maximum Operating Distance Wire Gauge AWG ft m 20 18 16 14 18 960 293 1500 457 2400 732 38...

Page 21: ...in 120 mm Total width of electrical box 4 75 in 121 mm Weight Approximately 2 25 lb 1 02 kg Construction Cast plastic aluminum and steel Finish Painted light gray smoked gray tint lower dome ENVIRONM...

Page 22: ...VF DN S4AVF DN C 1 4 CCD 2 1 interlace NTSC PAL Color Mono Color 550 Mono 580 Day 0 07 0 8 Night 0 009 0 1 at 40 IRE f 1 4 1 60 1 50 1 100 000 48 dB AGC off S4VFT 3312 1 3 ExView CCD 2 1 interlace NTS...

Page 23: ...ny equipment which may have been tampered with altered misused or been subject to unauthorized repair Software supplied either separately or in hardware is furnished on an As Is basis Vicon does not w...

Page 24: ...288 800 645 9116 Fax 631 951 CCTV 2288 Vicon Europe Headquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Germany vin videotronic infosystems gmbh Lahnstrasse 1...