background image

Important Safeguards 

GRAPHIC SYMBOL EXPLANATION 

13. Outdoor Cable Grounding -

 Use only grounded outdoor 

cables to protect against voltage surges and static charges. 
Section 810 of the National Electrical Code, ANSI/NFPA 70-
1984, provides information on proper grounding of the lead-in 
wire to an antenna discharge unit, size of grounding conductors 
and the requirements of grounding electrodes. 

The lightening bolt symbol alerts the user to the presence of 
dangerous voltage that may present the risk of electric shock. 

14. Lightning -

 Disconnect the product from its power source 

and cable system when possible to prevent damage due to 
lightning and power-line surges. 

15. Power Lines -

 Do not locate outside cables over power or 

utility lines where they can fall and make direct contact. Contact 
with power lines can be fatal. 

16. Overloading -

 Do not overload wall outlets and extension 

cords to prevent risk of fire and electric shock. 

 

The exclamation point symbol alerts the user to the presence of 
important operating and maintenance instructions. 

17. Object and Liquid Entry -

 Never probe through, or spill liquid 

into, enclosure openings to prevent risk of fire or electric shock. 

 

1. Read Instructions -

 Read all safety and operating instructions 

before the product is operated. 

18. Servicing -

 Refer all servicing to qualified service personnel. 

9. Damage Requiring Service -

 Obtain service when: 

b) 

c) 

r outdoor use and has been 

d) 

ubleshooting only to avoid unit damage and personal 

 

The product shows a significant change in performance. 

r an approved equivalent to prevent unit damage and 

ormed 

 to avoid component damage during installation and 

 to serve as the disconnect device, follow the 

uidelines below: 

a) 

device must be incorporated into the 

b) 

let must be installed 

near the unit and be easily accessible. 

1

2. Retain Instructions -

 Retain all safety and operating 

instructions for future reference. 

 
a)  The power-supply cord or plug is damaged. 

Objects have fallen or liquid has been spilled into the 

3. Heed Warnings -

 Pay attention to all product warnings. 

4. Follow Instructions -

 Follow all operating instructions. 

product. 
The product is not designed fo

5. Cleaning -(Do not use caustic, abrasive or aerosol 
cleaners) 

exposed to water or moisture. 
The product does not operate per the operating instructions. 
Perform Vicon recommended adjustments, modifications 
and tro

 

a)  For units that CAN BE DISCONNECTED from the power 

source, use a damp cloth for cleaning. 

injury. 

b) For

 

units that CANNOT BE DISCONNECTED from the 

power source, use a damp cloth for cleaning and do not 
allow moisture or liquids to enter vents. 

e)  The product has been dropped. 
f)

 

 

20. Replacement Parts -

 Use only Vicon specified replacement 

parts o

6. Attachments -

 Use only Vicon recommended attachments to 

prevent unit damage and personal injury. 

7. Water and Moisture -

 Use only products designed for outdoor 

environments where they will be exposed to water or moisture. 

injury. 

21. Safety Check -

 Request safety checks to be perf

8. Accessories -

 Do not place the unit on an unstable surface to 

avoid falling. Use only Vicon recommended mounting accessories.. 

following repair or maintenance to verify proper operation. 

22. ESD Precaution -

 Take all normal electrostatic discharge 

precautions

9. Ventilation -

 Do not block ventilating slots and openings as 

they ensure reliable operation. Do not place the unit near a heat 
source or into an enclosure unless recommended by Vicon. 

operation. 

23. For 230 VAC Devices-

 When the disconnect device is not 

incorporated in the equipment or when the plug on the power 
supply is intended

10. Power Sources -

 The product should only be operated from 

the recommended power source. If not specified, consult your 
Vicon dealer or local power company. 

g

11. Grounding -

 Only products equipped with a 3-prong 

grounded plug should be inserted into a grounded power outlet. 
Contact an electrician to replace an obsolete outlet. Do not force 
a plug into a non-grounded outlet. 

 

For permanently connected 230 VAC units, a readily 
accessible disconnect 
site wiring. 
For 230 VAC units with a plug, the out

12. Power Cord Protection -

 Power supply cords should not be 

routed in trafficked areas or in tight spaces where they will be 
pinched or used to bear weight. Allow some slack in the cord 
where it enters the unit. 

ii  

  Important Safeguards 

XX151-01-00 Rev 605 Surveyor4A Fixed-Position Camera Dome 

Summary of Contents for S4AFF-CHA

Page 1: ...ed for this purpose WARNING To reduce a risk of fire or electric shock do not expose this product to rain or moisture Copyright 2005Vicon Industries Inc All rights reserved Product specifications subject to change without notice Vicon and its logo are registered trademarks of Vicon Industries Inc VICON INDUSTRIES INC 89 ARKAY DRIVE HAUPPAUGE NEW YORK 11788 TEL 631 952 CCTV 2288 FAX 631 951 CCTV 22...

Page 2: ......

Page 3: ...ment off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the equipment with respect to the receiver Relocate the equipment away from the receiver Plug the equipment into a different electrical outlet so that the equipment and receiver are on different branch circuits If necessary the user should cons...

Page 4: ...w all operating instructions product The product is not designed fo 5 Cleaning Do not use caustic abrasive or aerosol cleaners exposed to water or moisture The product does not operate per the operating instructions Perform Vicon recommended adjustments modifications and tro a For units that CAN BE DISCONNECTED from the power source use a damp cloth for cleaning injury b For units that CANNOT BE D...

Page 5: ...spection for Concealed Damage 3 Surveyor4A Dome Components 3 Mounting the Unit 4 Camera Lens Adjustments 7 Final Installation 9 Operation 10 Maintenance 10 Care and Cleaning of Lower Dome 10 Shipping Instructions 11 Reference 12 Technical Information 14 XX151 01 00 Rev 605 Surveyor4A Fixed Position Camera Dome Contents iii ...

Page 6: ...Quick Installation iv Quick Installation XX151 01 00 Rev 605 Surveyor4A Fixed Position Camera Dome ...

Page 7: ...lenses A smoked lower dome is included A model is available that offers twisted pair video connection A UTP receiver is required for twisted pair configurations Refer to Table 1 for complete model descriptions The camera position is adjustable in four directions allowing for adjustment of pan tilt vertical height in the dome and rotation about the lens axis roll for any angle of view required The ...

Page 8: ...n ExView high resolution color camera and 2 6 6 mm autoiris varifocal lens 24 VAC isolated power input 4 inch smoked lower dome PAL coaxial cable video S4AVFT CHA 8402 00 1 3 in ExView high resolution color camera and 2 6 6 mm autoiris varifocal lens 24 VAC isolated power input 4 inch smoked lower dome NTSC twisted pair video S4AVFT CHA C 8402 01 1 3 in ExView high resolution color camera and 2 6 ...

Page 9: ...acket a mask and a smoked lower dome It includes a 4 x 4 electrical box for cable routing and mounting The camera lens assembly and lower dome are packed separately Enclosure The enclosure is a formed plastic housing that includes the camera mounting bracket and cable connectors The assembly is mounted into a 4 x 4 electrical box which allows neat routing for all cabling A safety cord is provided ...

Page 10: ... route the cables through the connector and into the box 3 Compress the mounting bracket flush to the electrical box and insert the box into the hole in the ceiling The right angle brackets on the bottom of the electrical box will be outside the hole Refer to Figure 2 4 Tighten the screws in the top of the electrical box This expands the bracket that is on the box and squeezes the box into the cei...

Page 11: ... BNC to the pendant cable female BNC connector on the top of the enclosure ALTERNATE CONNECTION For the model using the twisted pair video connection use the twisted pair video wires as shown in Figure 5 Strip off approximately 0 25 in 6 mm of insulation from each individual wire Attach each wire to the screw terminal on the top of the enclosure This signal is polarized and specific wire connectio...

Page 12: ...llation Refer to the table below For other multichannel power supplies contact Altronix Corporation at 888 258 7669 Model Number Description VC24PS 1 Single channel indoor 24 VAC V248 3 5PS 8 channel indoor 24 VAC 0 4 A channel V2416 8PS 16 channel indoor 24 VAC 0 5 A channel 6 Installation XX151 01 00 Rev 605 Surveyor4A Fixed Position Camera Dome ...

Page 13: ... the power source If the camera experiences roll or jitter due to the quality of the power source then it is best to set the camera to internal crystal mode This is done by setting the selector switch to INT as shown in Figure 6 Camera Lens Adjustments After all cabling is complete the camera and lens can be adjusted Switch Settings There is a DIP switch on the front camera board that allows the s...

Page 14: ...equired if the picture appears dark or grainy or has poor color There is a potentiometer VR1 on the camera front board to adjust the autoiris Refer to Figure 5 Turning the potentiometer opens and closes the iris to regulate light extremes Turning the potentiometer clockwise opens the iris wider allowing more light Figure 5 DIP Switch and Potentiometer Location Figure 6 Switch Settings 8 Installati...

Page 15: ...n axis up to 360 roll adjustment Note After all adjustments are made be sure to tighten all bracket screws Final Installation When the camera and lens adjustments are complete the lower dome assembly can be installed Refer to Figure 7 Lift the mask lower dome trim ring assembly up to the installed enclosure and align the molded ribs inside the mask with the pan arm on the camera mounting bracket T...

Page 16: ...ressed air cans 3 If spots streaks or stains appear on the interior or exterior they can be removed with a solution of isopropyl alcohol and water using a microwave safe aluminum free paper towel Dry with clean dry pressurized air 4 Scratches or surface blemishes on the exterior or interior may be removed with a nonabrasive wax using a soft cleaning cloth Either liquid or spray cleaner wax suitabl...

Page 17: ...ed Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Name and address of the company returning the unit b Name of the Vicon employee who issued the R A c R A number d Brief description of the installation e Complete description of the problem and circumstances under which it occurs f Unit s original date of purchase if still ...

Page 18: ...es are RG 59 U and RG 11 U Each is actually a family of cables with widely varying electrical characteristics some of which are not suitable for CCTV applications Choose a cable type by referring to the characteristics and maximum distances listed below The maximum distance for best picture refers to the distance between the camera and the unit The characteristics of the cables in this table shoul...

Page 19: ...ent as a twisted pair the blue white white blue wires twisted together as a pair not a split pair blue white conductor part of one pair orange white conductor part of another pair Choose a Belden or equivalent cable type by referring to the characteristics and maximum distances listed below The characteristics of the cables in the Tables should be used as a guideline when cables other than Belden ...

Page 20: ...ermining the extent of cooling required for an D Wire Gauge AWG ft m 16 2400 7 Pow r 3 pin termi l 20 18 14 18 960 293 1500 457 32 3840 1170 6000 1829 Connectors e na Video BNC on pendant cable or UTP terminal adio F equen mission Rating FCC Class A Refer to Table 3 al djustment 4 axis adjustment pan tilt vertical height of camera lens and roll lens may be rotated on its axis 360 MECHANICAL Indoor...

Page 21: ...lb 1 02 kg Construction Cast plastic aluminum and steel Finish Painted light gray smoked gray tint lower dome ENVIRONMENTAL Operating Temperature Range 35 to 104 F 2 to 40 C Operating Humidity Up to 90 relative noncondensing Storage Temperature Range 40 to 150 F 40 to 65 C Storage Humidity Up to 90 relative noncondensing XX151 01 00 Rev 605 Surveyor4A Fixed Position Camera Dome Technical Informati...

Page 22: ... 2 1 interlace NTSC PAL Color 480 0 07 0 8 at 40 IRE f 1 6 1 60 1 50 1 100 000 48 dB AGC off S4AVF DN S4AVF DN C 1 4 CCD 2 1 interlace NTSC PAL Color Mono Color 480 Mono 580 Day 0 07 0 8 Night 0 009 0 1 at 40 IRE f 1 4 1 60 1 50 1 100 000 48 dB AGC off Lens Specifications Model Focal Length mm Field of View Horizontal Vertical S4AVF CA S4AVF CA C 2 6 6 varifocal with autoiris 106 47 6 78 2 35 8 S4...

Page 23: ...obligated to repair or replace equipment showing abuse or damage or to parts which in the judgment of the Company are not defective or any equipment which may have been tampered with altered misused or been subject to unauthorized repair Software supplied either separately or in hardware is furnished on an As Is basis Vicon does not warrant that such software shall be error bug free Software suppo...

Page 24: ...rters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium 32 2 712 8780 Fax 32 2 712 8781 Far East Office Unit 5 17 F Metropole Square 2 On Yiu Street Shatin New Territories Hong Kong 852 2145 7118 Fax 852 2145 7117 Internet Address www vicon cctv com ...

Reviews: