background image

Cable Recommendations 

Caution: 

Careful selection of proper cable is essential to obtain the best performance from this equipment. Vicon assumes no 

responsibility for poor performance when cables other than those recommended, or equivalent, are installed. In all cases, coaxial cable 
impedance should be 75 ohms. 

 

Materials 

Use only a pure copper center conductor. Do not use a copper-plated steel or aluminum center conductor, as they will 
result in poor quality video. Solid-core bare copper conductor is the best type where flexing and bending will be minimal. If 
severe bending and flexing is required for installation, use a stranded center conductor. Never exceed the manufacturers 
minimum bend radius specification. Use cellular (foam) polyethylene dielectric except where heavy moisture exists. For 
moisture conditions, use solid polyethylene dielectric cable with a heavy exterior insulation. The shield must be copper 
braid providing 95% or better coverage. 
 

Cable Types 

The cable types listed below are the most common 75-ohm types used. They vary in size (diameter), dielectric type and 
net DC resistance. The larger cable results in a lower DC resistance and better video quality, with increased difficulty in 
handling and installation. Use the required picture quality and cable distance to provide a guide in choosing the best cable 
type. For cables other than the approved Vicon types below, contact the manufacturers listed below. Note that “BC” refers 
to bare copper and “TC” refers to tinned copper. 
 

Recommended Coaxial Cable Types 

Cable 

Type 

Belden 

Type No. 

Alpha 

Type No. 

West Penn 

Type No. 

Type Center 

Conductor 

Type Shield and 

% Coverage 

DC Resistance 

ohms/1000 ft (1 km) 

RG-11/U 

8213 9847 811,4811 

14 

Solid 

BC 

BC braid (95%) 

2.6 (8.5) 

RG-6/U 

9248 

9804C 

806,4806 

18 Solid BC 

Foil + 61% TC braid (100%) 

7.5 (24.6) 

RG-59/U 

8281* 

---- 

815 

20 Solid BC 

2 TC braids (96%) 

9.9 (32.5) 

RG-59/U 

9259 9803 816 

22 

Stranded 

BC 

BC braid (95%) 

15.0 (49) 

RG-59/U 9659 

---- 

---- 

22 

Stranded BC 

BC braid (95%) 

15.0 (49) 

*Requires special BNC-M connector due to 0.305 nominal O.D. 
Belden Inc.  

 

http://www.belden.com/ 

 

(800) 235-3361 

Alpha Wire Company 

http://www.alphawire.com/ 

 

(800)-52 ALPHA (522-5742) 

West Penn Wire 

 

http://www.westpenn-cdt.com/  

(800)-245-4964     

 

Picture Quality vs. Cable Length 

Maximum Cable Run** ft (m) 

Picture Quality 

RG-59/U RG-6/U RG-11/U 

Usable picture 

1100 (350) 1500 

(450) 2400 

(750) 

Clean picture 

820 (250) 

1000 (300) 

1600 (500) 

Best picture 

400 (120) 

530 (160) 

820 (250) 

         ** For longer cable runs, use a Vicon Video Amplifier to obtain a suitable picture 
 

Usable Vicoax Signal vs. Cable Length

 

Maximum Cable Length ft (m) 

RG-59/U RG-6/U  RG-11/U  Fiber 

Usable Vicoax 

signal 

1500 (450) 

1500 (450) 

5000 (1524)  5000 (1524) 

 

10  

 Cable Recommendations 

XX077-50-00 Rev 1202 S2000-MSH-HHB Heater/Blower Version 

Summary of Contents for S2000-MSH-HHB Surveyor 2000

Page 1: ...life critical situations and must not be used for this purpose Copyright 2002 Vicon Industries Inc All rights reserved Product specifications subject to change without notice Vicon and its logo are registered trademarks of Vicon Industries Inc VICON INDUSTRIES INC 89 ARKAY DRIVE HAUPPAUGE NEW YORK 11788 TEL 631 952 CCTV 2288 FAX 631 951 CCTV 2288 TOLL FREE 800 645 9116 24 Hour Technical Support 80...

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ...and Inspection 3 Accessory Kit 3 INSTALLATION 6 Mounting the Unit 6 OPERATION 8 MAINTENANCE 8 Care and Cleaning of Clear Acrylic Domes 8 Fuse Replacement 8 SHIPPING INSTRUCTIONS 9 CABLE RECOMMENDATIONS 10 Twisted Pair Cable 11 TECHNICAL INFORMATION 12 XX077 50 00 Rev 1202 S2000 MSH HHB Heater Blower Version Contents 1 ...

Page 6: ...Quick Installation Q U I C K I N S T A L L A T I O N Q U I C K I N S T A L L A T I O N 2 Quick Installation XX077 50 00 Rev 1202 S2000 MSH HHB Heater Blower Version ...

Page 7: ... Enclosure a sealed Lower Dome assembly a Power Termination Block and mounting studs for the Surveyor2000 Camera Drive In addition the Housing provides outside holes for external mounting brackets and tamperproof hardware for Lower Dome removal Unpacking and Inspection All Vicon equipment is tested and inspected before leaving the factory It is the carrier s responsibility to provide suitable deli...

Page 8: ...solution camera Exview HAD CCD S2 MW22C 8216 01 1 4 in monochrome camera CCIR version 22x zoom high resolution camera Exview HAD CCD Table 2 Surveyor2000 Camera Drive Models Product Codes and Descriptions Model Product Code Description S2000 MSH WM 7620 00 Wall Mount with Tamperproof Bit S2000 MSH CM 7619 00 Ceiling Mount with Tamperproof Bit S2000 MSH S 7711 00 Sunshield can only be used with Wal...

Page 9: ...Figure 1 Exploded View XX077 50 00 Rev 1202 S2000 MSH HHB Heater Blower Version Introduction 5 ...

Page 10: ... pre installed Tamperproof Screws Use the Tamperproof Bit provided with Mounting Bracket for installing screws 4 Prepare the Termination Boxes and cables There should be a maximum of 5 cables for power video communications alarm and relay Route the cables through the Liquid Tight Conduit Fitting and leave about 12 in 305 mm length for connection to the Camera Drive for every cable except power The...

Page 11: ... open J3 8 RO Response out Table 4 Electrical Connections 7 Configure communication and address DIP switches For example DIP SWITCH S1 Address 1 1 ON 2 OFF 4 OFF 8 OFF 16 OFF 32 OFF 64 OFF 128 OFF DIP SWITCH S2 typical configuration 1 ON NTSC 2 OFF VPS 3 OFF DUPLEX 4 OFF RS 422 5 through 8 OFF not used For a detailed description of DIP switch configuration refer to the Configuration section of the...

Page 12: ...r using a lint free soft paper towel Dry with clean dry pressurized air 4 Scratches or surface blemishes on the exterior may be removed with a nonabrasive wax using a soft cleaning cloth Caution Excessive rubbing of the Lower Dome surface can cause permanent scratches 5 Clean all surfaces with any soft cleaning cloth and a mild glass cleanser suitable for acrylic plastic Fuse Replacement Two fuses...

Page 13: ...d Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Name and address of the company returning the unit b Name of the Vicon employee who issued the R A c R A number d Brief description of the installation a Complete description of the problem and circumstances under which it occurs b Unit s original date of purchase if still u...

Page 14: ...ture quality and cable distance to provide a guide in choosing the best cable type For cables other than the approved Vicon types below contact the manufacturers listed below Note that BC refers to bare copper and TC refers to tinned copper Recommended Coaxial Cable Types Cable Type Belden Type No Alpha Type No West Penn Type No Type Center Conductor Type Shield and Coverage DC Resistance ohms 100...

Page 15: ...ons Single individually shielded twisted pair is also a suitable cable Choose a Belden cable type by referring to the characteristics and maximum distances listed below The maximum distance for the most reliable digital control refers to the distance between the CPU Keypad and the Camera Dome Assembly The characteristics of the cables in Table 6 should be used as a guideline when cables other than...

Page 16: ...alent 8 75 btu min 2 2 kg cal min Note These figures represent the conversion of 100 of the electrical energy to heat Actual percentage of the heat generated will be less and will vary from product to product These figures are provided as an aid in determining the extent of cooling required for an installation Program Memory Type Field reprogrammable flash type memory Connectors Types Communicatio...

Page 17: ...y function activation calling autotours tour repeat or chaining tours Autotour Capabilities 2 autotours available with 360 pan tilt and zoom functions per autotour Programming is done in real time with joystick and push buttons Preset Solving Speed 1 second nominal Preset Repeatability 0 3 maximum Alarm Capabilities 4 alarm inputs Individual input enable disable Alarm report to CPU enable disable ...

Page 18: ... Programmable for Camera Preset Sector and Alarms Fixed for Relay function and lens status Camera 1 for each Preset 79 maximum Sector 16 maximum Alarm 4 maximum Individual type enable disable 20 characters maximum Selectable position MECHANICAL S2000 MSH Housing only Application Indoor or outdoor Mounting Ceiling or Wall mounting with separately purchased Mounting Brackets See Table 3 Cable Access...

Page 19: ...2000 MSH WM 11 75 lb 5 3 kg S2000 MSH CM 9 5 lb 4 3 kg Construction Housing 13 gauge 0 089 in 23 mm thick welded steel Mounts 0 19 in 4 8 mm thick steel Finish Paint Color Gray Figure 2 Dimensions XX077 50 00 Rev 1202 S2000 MSH HHB Heater Blower Version Technical Information 15 ...

Page 20: ... 122 F 40 to 50 C Note The Sunshield cannot be used with the S2000 MSH CM Ceiling Mount Bracket Operating Humidity Range 100 relative humidity Storage Temperature Range 40 to 150 F 40 to 65 C Storage Humidity Range Up to 90 relative noncondensing Ingress Protection EN60529 IP 65 rated Wind Load 90 mph using optional ceiling or wall mount 16 Technical Information XX077 50 00 Rev 1202 S2000 MSH HHB ...

Page 21: ...NOTES XX077 50 00 Rev 1202 S2000 MSH HHB Heater Blower Version Technical Information 17 ...

Page 22: ...rters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium 32 2 712 8780 Fax 32 2 712 8781 Far East Office Unit 5 17 F Metropole Square 2 On Yiu Street Shatin New Territories Hong Kong 852 2145 7118 Fax 852 2145 7117 Internet Address www vicon cctv com ...

Reviews: