Operation
When power is applied to the Camera Drive, it will boot up through a diagnostic routine and view the currently
selected scene. Refer to the Surveyor2000 Programming Manual XX034 for details on setup and operation.
Maintenance
The S2000-MSH-HHB Camera Dome requires no scheduled maintenance except for the occasional cleaning
of the Lower Dome.
Care and Cleaning of Clear Acrylic Domes
1. Always handle the Lower Dome by the flange and avoid touching the inside surface.
2. If dust or dirt accumulates in the Lower Dome's interior, remove it with clean dry pressurized air.
3. If spots, streaks or stains appear on the exterior, they can be removed with a solution of mild soap or
isopropyl alcohol and water using a lint-free soft paper towel. Dry with clean, dry pressurized air.
4. Scratches or surface blemishes on the exterior may be removed with a nonabrasive wax using a soft
cleaning cloth.
Caution:
Excessive rubbing of the Lower Dome surface can cause permanent scratches.
5. Clean all surfaces with any soft cleaning cloth and a mild glass cleanser suitable for acrylic plastic.
Fuse Replacement
Two fuses (F1 and F2) are located on the Communication/Power Supply Board of the Camera/Drive. When
necessary, replace fuses with the following values:
F1: 2AG, 1.6 amp, 250 volt, slo-blo
F2: 2AG, 2.5 amp, 250 volt, slo-blo
One fuse is located on the side of the Heater/Blower Assembly. When necessary, replace it with a fuse of the
following value:
5 x 20mm, 4 amp, slo-blo
Note:
Refer to the Surveyor2000 Installation & Operation Manual for Camera Drive maintenance.
8
•
Operation
XX077-50-00 Rev 1202 S2000-MSH-HHB Heater/Blower Version