X777-08 Rev 1202 Intelligent Remote Control Panels
Operation
•
11
Defaults
When the keypad is shipped from the factory, the following defaults are set:
Field Default
Keypad Type
1200
Speed Control Type
1200
Receiver Function Inhibit
No
Joystick Response
Medium
Baud Rate
9.6 k
Keypad Address
192 (0C0H hex)
Manager Passcode
000000
Auto-Logout Off
You may reset your settings to the factory defaults by performing the following procedure.
1. Press and hold the F1 key and then press the SEQ key.
2. Press SEQ repeatedly until “Install Default Parameters” displays.
3. Use the joystick to select Yes.
4. Press PP ENTER.
5. Verify your selection by selecting Yes again with the joystick and press PP ENTER.
Operation
Note: Place the RUN/PGM switch in the RUN position.
Alarms
Note:
(V1300/V1344 only)
You may set a dwell time for sequencing alarms (alarms must be defined to
sequence in the V1300/V1344 menus) by entering the time and pressing Dwell while holding down
Alarm.
Acknowledging Alarms
Viewing Alarm Video
For control systems with an independent stack
mode, press ALARM again after all alarms are
cleared from the currently-selected alarm
monitor. This will select the next alarm monitor
if it has active alarms. Continue with the alarm
acknowledgment procedure to clear alarms.
To view but not acknowledge
alarms, press SEQ or BYPASS
to step through active alarms.
SEQ will step you through the
alarms from the first active
alarm to the last active alarm.
BYPASS will step through
the alarms from the last
active to first active alarm.
If the ALARM LED
illuminates, press ALARM to
view the alarm video. (If
alarms are sequencing, the
first press of the ALARM key
will stop the sequencing.)
If the ALARM
LED remains
illuminated, press
ALARM until all
alarms are
cleared.
Press
ALARM to
clear the
alarm.
Notes: If the currently-selected monitor is not defined as an alarm monitor, press ALARM before performing the procedure
below in order to select the lowest numbered alarm monitor. Monitors are defined as alarm monitors as discussed in the
programming manual for your control system.
ALARM
PASS
SEQ
BY
OR
Summary of Contents for Nova V1300-DVC