XX185-30 Rev 807 Kollector Lite
Configuring the ViconNet System
•
127
Activating Relays in Macros
The Kollector rear panel has four relay outputs that can be toggled between the states Open (Off) and
Closed (On), or Momentarily enabled for a set duration. On system start up, the relay state is Normally
Opened (NO).
These relays can be used to drive indicators and alarm enunciators and to enable or disable devices. Within
a macro, any number of relays can be activated between as many states as desired. The relay can be
directly connected to a switching load with maximum ratings of 60 VAC or DC at 1.0 Amp current.
To activate a relay in a macro:
1. Follow steps 1 to 6 of the
To create a macro
procedure.
OR
Select a macro from the list at the top of the
Macro Editor
window and click
Edit Macro
.
2. To configure a relay function in the macro, click the
Relay
button. The relay configuration options are
displayed at the bottom of the window.
3. Select
On
(Closed),
Off
(Open) or
Momentarily
(configurable between 500 and 2500ms).
4. Click
Apply
.