background image

COMMISSIONING THE CAMERA

-5-

Commissioning the Camera

Tips for Camera Location

1.0 To avoid internal overheating:

-

  never expose the camera to direct sunlight without additional camera housing

-

  keep sufficient distance to direct heat sources.

2.0 Never install the camera at humid, oily or dusty locations without using an

additional housing. (without additional housing the camera is not suitable for
outdoor use!)

3.0 The camera should be installed out of reach (min. height: 2.30 m)

4.0 Do not aim the camera towards indoor lighting, the windows, the sunlight or the

sky (to get good pictures, camera and light should be aimed towards the object)

5.0 Reduce the picture detail to the

essential parts of the picture and
place the camera as close as possible
to the object (a smaller picture detail
guarantees sharper details).

6.0 Do not aim the camera towards a

window but instead towards the room.

7.0 Outdoors the camera should be

placed as high as possible so that the
horizon does not appear in the
picture.

8.0 Avoid peak light as background (also

caused by reflections, e.g. window
panes).

        wrong                   right

Summary of Contents for IX 1000 H

Page 1: ...s system has not been designed to be used in life critical situations and must not be used for this purpose Copyright 2006 Vicon Industries Inc All rights reserved Product specifications subject to change without notice Vicon and ist logo are registered trademarks of Vicon Industries Inc VICON INDUSTRIES INC 89 ARKAY DRIVE HAUPPAGE NEW YORK 11788 TEL 631 952 CCTV 2288 FAX 631 951 CCTV 2288 TOLL FR...

Page 2: ...l advantage of all quality features regarding this product line Contents Page General Information Safety Precautions 3 Accessories and Additional Devices 3 Mounting the Camera Mounting the Camera to a Wall Mount 4 Commissioning the Camera Tips for Camera Location 5 Adjustment of Back Focus 6 Calibration of ES DC Lenses 6 Focusing the Camera Lens 7 Circuit points and operation 8 Lense mounting and ...

Page 3: ...be carried out by authorised personnel In case of ourdoor use you have to install the camera in a suitable weather protection case incl heating element If any liquid or solid matter should get into the housing disconnect the camera from power supply and have it checked by your authorised dealer before re using danger of electronic shock Do not disassemble the camera To avoid electric shocks never ...

Page 4: ...MOUNTING THE CAMERA 4 Mounting the Camera Mounting the Camera to a Wall Mount ...

Page 5: ...out of reach min height 2 30 m 4 0 Do not aim the camera towards indoor lighting the windows the sunlight or the sky to get good pictures camera and light should be aimed towards the object 5 0 Reduce the picture detail to the essential parts of the picture and place the camera as close as possible to the object a smaller picture detail guarantees sharper details 6 0 Do not aim the camera towards ...

Page 6: ...D chip until the picture is in focus Then fix the Allan head screw using the Allan head key 3 Finally focus the picture using the lens focus ring Adjustment of ES DC Lenses To adjust a lens with automatic iris DC driven or video driven to the camera please proceed as follows 1 Turn the level potentiometer position ES lenses at the lens itself DC lenses at the camera to the max position H turn righ...

Page 7: ...e lens provided you are using a lens with automatic iris Adjust the focus while the iris is fully open using the lens focus ring Make sure the most important picture details are in optimum focus use a service monitor If it is not possible to bring the picture into focus please adjust the back focus of the camera as described above If you intend to use I R illumination at a later stage you must use...

Page 8: ...l Rear view 230 V AC Model Video ELC DC Change over between video drive lenses Video Auto Shutter ELC and DC drive lenses DC DC LEVEL Shutter adjustment during DC lense operation PL Power signal FL Flickerless on off AGC Automatic gain on off BLC Back Light Control on off AC24V DC 12V Power connection the polarity with 12V DC makes no difference FG Not connected 230V AC Mains voltage connecting le...

Page 9: ...CIRCUIT POINTS AND OPERATION 9 Lense mounting and connection ES Control DC Control 1 8 5 V DC 1 Control 2 NC 2 Control 3 ES Signal 3 Drive 4 Ground GND 4 Ground GND ...

Page 10: ...re is not sharp Focus not adjusted properly Back focus not adjusted properly When used outdoors heater defective front pane of camera housing gets steamy The picture is distorted Different GND potentials between camera and monitor use opto coupler e g VPT from videotronic Bad connections Ghost image Wrong 75 W termination Shield of video cable interrupted Synchronisation of cameras does not work p...

Page 11: ...B AGC OFF AGC ALC ON OFF 28dB Synchronisation 12V DC Intern 24V AC 230V AC Linelock Backlight compensation ON OFF White Balance AWB Day Night Function No Auto ICR Video output signal Composite 1VSS 75 Ohm Signal system PAL 625 Lines Power source L Version 12V DC 24V AC Dual H Version 230V AC Power consumption 2 0 2 8W 3 0W 12VDC 24VAC 230VAC Operating Temperature 10 C 50 C recommended 5 C 40 C Len...

Page 12: ...nd may only be done by your authorised dealer Since all camera functions are self adjusting and the camera does not contain any parts or components that are subject to wear we advise you not to open the camera except for the flap for settings unless the camera appears to be defective Make sure to include these instructions when handing the camera over to third parties Technical Support Should you ...

Page 13: ...NOTES 13 ...

Page 14: ...NOTES 14 ...

Page 15: ... Vicon Europe Ltd Brunel Way Fareham PO 15 5TX United Kingdom Phone 44 0 1489 566 300 Fax 44 0 1489 566 322 2 Attach a sheet of paper to the unit with the following information a Name and address of th ecompany returning the unit b Name of the Vicon employee who issued the R A c R A number d Brief description of the installation e Complete description of the problem and circumstances under which i...

Page 16: ...rters Brunel Way Fareham PO 15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium 32 2 7128780 Fax 32 2 7128781 Far East Office Unit 5 17 F Metropole Square 2 On Yiu Street Shatin New Territories Hong Kong 852 2145 7118 Fax 852 2145 7117 Internet Address www vicon cctv com ...