9
Camera Configuration
The I-ONYX MP-955IR megapixel cameras are configured in a different way than other ViconNet cameras.
Initial setup and configuration are NOT done through VNSetup software but through a Web Browser
interface. These cameras will not show up on the ViconNet Setup Site Selection list.
Note: If your camera network is an active DHCP server, the camera will be assigned a DHCP address. For
initial configuration, connect the camera directly to the PC using a crossover cable or locally to bypass
the DHCP server. Refer to Appendix for instructions on locating cameras with unknown IP addresses.
Network Settings
The default IP address of the MP-955IR camera is 192.168.0.100. Make sure the IP camera and your PC
are on the same network subnet mask (segment) before attempting to access the camera.
Note: All cameras are factory set to the same default IP address; to avoid IP conflicts, only one camera can
be connected and setup at a time. After a camera has been defined, another camera can be
connected.
IP address: 192.168. 0.xxx
Subnet mask: 255.255.255. 0
(
NOTE
: xxx can be any number
from 1 to 254 with the exception
of 100.)
Enter the IP settings as below:
You can use these settings on
your computer network settings if
needed:
Open Internet Explorer with the camera’s IP address.
Note: If your Web browser is earlier than Internet Explorer 6 (IE6), it is recommended to upgrade to IE6.
Vicon recommends using Internet Explorer as the browser and cannot guarantee full functionality with
any other browser.
XX194-10-04 Rev 110 MP-955IR Megapixel Camera