VICI DBS NM PLUS 100 User Manual Download Page 26

26

NM PLUS HYDROGEN GENERATOR

USER MANUAL

www.vicidbs.com

Version 1.06.0000

PART NUMBER

DESCRIPTION

DB-H200-031

Deionizer bags (pk 2)

DB-10573

Maintenance kit for NM Plus contains:

• 

Water tubing kit plus

• 

Deionizer LE bag (Pack of 2 pcs.)

• 

Perma pure dryer tubing (2 pcs)

• 

GLS Service Kit

9.2. Maintenance Kit

10. SCHEMATICS

NM PLUS

CELL  

PART #

DRYER PART # 

(PURGE FLOW)

FLOW METER 

PART # (TYPE)

WATER  

BYPASS

BUFFER  

RESERVOIR

100/160

DB-CELL-MI

DB-NMP200-000

 

(50 mL)

DB-10562 (low flow)

Yes

No

250/300

DB-CELL-MU1

DB-NMP200-000 

(50 mL)

DB-10562 (low flow)

Yes

No

400/500/600

DB-CELL-MU2

DB-NMP200-000 

(50 mL)

DB-PH200-009 

 

(high flow)

No

No

1000

DB-CELL-MU3

DB-NMP200-001 

(90 mL)

DB-PH200-009 

 

(high flow)

No

Yes

1350

DB-CELL-MU4

DB-10341 (120 mL)

DB-PH200-009 

 

(high flow)

No

Yes

10.1. Fluidic Schematics

System:

Schematic no:

Date:

Created:

Checked:

Released:

THIS DOCUMENT AND THE INFORMATION WHICH

IT CONTAINS SHALL NOT BE USED, EXPLOITED

OR SOLD, AND SHALL NOT BE REVEALED OR

DISCLOSED TO OTHERS WITHOUT THE EXPRESS

WRITTEN PERMISSION OF VICI. THIS DOCUMENT

SHALL REMAIN THE PROPERTY OF VICI AND

SHALL BE RETURNED UPON DEMAND.

R

 Rev.:

Sheet:

By:

Description:

ECN no:

NM Plus with PRB
water and hydrogen flow diagram

06.10.2020

06.10.2020

SBU

SB

1

1/1

Summary of Contents for NM PLUS 100

Page 1: ...merica techsupportusa vicidbs com Italy service vicidbs com VICI AG INTERNATIONAL Parkstrasse 2 CH 6214 Schenkon Switzerland tel 41 41 925 6200 fax 41 41 925 6201 web www vicidbs com APPLICABLE MODELS...

Page 2: ...6 2 Packing List 12 6 3 Placing the Generator 12 6 4 Gas Connections 13 6 5 Electrical Connections 13 6 6 Initial Start Up 14 6 6 1 Filling the Water Tank 14 6 6 2 Installing the Deionizer Bag 15 6 6...

Page 3: ...27 28 11 SPARE PARTS LIST 29 31 TABLE OF CONTENTS 1 VERSION HISTORY VERSION DATE COMMENT CHANGE 1 00 0100 1 10 2017 Layout and initial release VICI DBS 1 01 0000 Update 1 02 0000 5 25 2018 Added the...

Page 4: ...at the current situation needs operator awareness or operator action in order to avoid undesirable consequences The manual must be consulted in all cases where this symbol is marked on the device Risk...

Page 5: ...ollowing measures Reorient or relocate the receiving antenna Increase the distance between the equipment and the receiver Connect the equipment to an outlet on a circuit different from that to which t...

Page 6: ...00 cc min Cell pn DB Cell MU3 NM Plus 1350 0 1350 cc min Cell pn DB Cell MU4 MAX OUTLET PRESSURE 11 barg 160 psi PURITY 99 99996 POWER CONSUMPTION W AND WEIGHT KG NM Plus 100 100 W 14 kg NM Plus 160 1...

Page 7: ...ical cell assembly which contains a solid polymer electrolyte No free acids or alkaline are used Deionized or pure distilled water is the only liquid which will come into contact with the cell As this...

Page 8: ...cts The contacts can be configured via software as normally open or normally closed see the Configuration section The maximum voltage and current ratings for the contacts are 1A 48V The pin configurat...

Page 9: ...mes the master and controls the others slaves If there is a problem with the master one of the slave generators will become the master Every generator can be forced to be the master by opening the men...

Page 10: ...ater line or a reservoir with deionized water The kit includes a pump and a valve they assure a constant flow of water The system automatically recognizes when to start and when to stop the refilling...

Page 11: ...ORIGINAL packaging is case of a return Ordering Information for Options Part Number Boards and Interfaces I O Board pn DB 10154 Remote Control RS232 Software Cable pn DB PH200 107 Remote Control USB S...

Page 12: ...ce as this may cause the generator to overheat The unit should not be in contact with any other objects on any side and the Air inlet must not be blocked Leave at least 30 cm of free space at the rear...

Page 13: ...t at the rear of the unit can be connected to an exhaust hood or another venting system Remove the cap from the H2 vent IMPORTANT Remove the plugs from the hydrogen vents before operating the unit Kee...

Page 14: ...or deionized water The conductivity of the water used in the generator must not exceed 2 S cm Fill the tank to the maximum level indicator Close the slider cap Do not fill the water tank higher than...

Page 15: ...k with distilled or deionized water the 2 deionizer bags supplied must be placed in the tank Inspect the bags thoroughly for holes or tears indicated by loose deionizer beads on the outer surface If t...

Page 16: ...reaches the set value These values are shown on the LCD display It may take a few minutes to reach the set operating pressure 1 Once the pressure reaches the set value the LCD display will show the me...

Page 17: ...y provides the following information Shows current status of the generator The information can be divided into 3 groups Information Displays normal operating status Pre Alarm Indicates that a maintena...

Page 18: ...timeout Clock Failure The clock is not set If the generator is disconnected for more than 2 4 week the time setting may be lost Pre Alarm Set clock Low Int Pressure The internal pressure cannot be re...

Page 19: ...en resolved the Reset button must be pressed before the generator can be restarted also see Special Functions The Reset button is also used to access the menu 7 1 7 Exit Menu Button Exit returns to pr...

Page 20: ...shown on the main screen of the graphic display The main screen has three options at the bottom corresponding to the three buttons on the unit and the touch screen which are used to run the various f...

Page 21: ...the cascading mode see cascading for more details On Off Off N Gen H2 in Cascading Sets the number of generators in the cascad ing chain 1 10 1 ID Number Sets the ID Number 1 10 1 Remote Start Stop M...

Page 22: ...cycle System Test This offers several test functions see below Internal Leak Test The outlet valve is closed the pressure is set to the max when the pressure reaches the max production is stopped and...

Page 23: ...tion and quotation you decline the repair you may be subject to a service fee to cover product decontamination disassembly cleaning and evaluation Please also be advised that by sending your gas gener...

Page 24: ...ion of the hydrogen generator 9 1 1 Cleaning The internal components of the hydrogen generator do not need to be cleaned and should not be accessed by the user for cleaning To clean the outside of the...

Page 25: ...s 300 DB Cell MU1 single layer cell 1 DB H200 031 NM Plus 400 DB CELL MU2 two layer cell 1 DB H200 031 NM Plus 500 DB Cell MU2 two layer cell 1 DB H200 031 NM Plus 600 DB Cell MU2 two layer cell 1 DB...

Page 26: ...000 50 mL DB 10562 low flow Yes No 400 500 600 DB CELL MU2 DB NMP200 000 50 mL DB PH200 009 high flow No No 1000 DB CELL MU3 DB NMP200 001 90 mL DB PH200 009 high flow No Yes 1350 DB CELL MU4 DB 10341...

Page 27: ...in GLS DB H200 007 G L separator complete with fittings Over pressure relief DB H200 035 Pressure release valve Perma Pure tube DB H200 034 Perma Pure for all versions Dryer board DB NMP200 003 Dryer...

Page 28: ...DB 10350 Kit Water Pump SANSO complete Water tank DB PH201 000 Water tank complete PG Plus NM Plus PRB DB 10638 Pressure release block PRB MODEL POWER SUPPLY MAIN BOARD DIODE FLOW METER TYPE CELL 100...

Page 29: ...100 160 250 300 DB PH200 004 Big Power Supply PG plus NM plus 500 600 1000 DB H200 006 Ball valve for cell IN pre mounted in a tubing DB H200 040 80mm axial fan DB PH200 002 Internal circulation fan P...

Page 30: ...15368 PHGS170915444 DB 10021 Tygon tubing 2375 ID 1 4 OD 3 8 Thickness 1 16 DB 10022 Tygon tubing 2375 ID 1 8 OD 1 4 Thickness 1 16 DB 10051 PP tubing white 1 8 DB 10146 Service kit for GLS V1 v1 5 co...

Page 31: ...Red tap for H2 vent DB 10490 Kit Fittings for pump SANSO incl inlet and outlet adapters and L bows DB 10255 APC 1 4 hose barb non valved in line coupling body DB 10256 Water connector male PMC 1 4 DB...

Reviews: