Viceroy Installation Instructions
3 |
P a g e
all-pole disconnection incorporated in the fixed wiring in accordance
with the wiring rules.
Example: If a fan is connected to a circuit that can be isolated via an
all-pole safety switch at the switchboard, then this is considered to be an
all-pole disconnection to the ceiling fan electrical circuit, meeting the
requirements of clause 7.12.2 of AS/NZS 60335.1.
A single-pole switch also must be placed in the same room as the
fan as per local wiring regulations AS3000
5.
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.
Contact your local government for information regarding the collection systems available. If electrical appliances
are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food
chain, damaging your health and well-being.
6. The structure to which the fan is to be mounted must be capable of supporting a weight of 30kg.
7. The fan should be mounted so that the blades are at least 2.3m above the floor in Europe or 2.1m above the floor in
Australia.
8. This fan is designed for indoor use only. Mounting the fan in a location where it is subject to water or moisture is a
hazard and will void the warranty.
9. Only a licensed electrician should execute the installation.