background image

9

Fixturlaser EVO

R E - M E A S U R E   &   D O C U M E N T

Re-Measure

1.

 

Press the re-measure button, then press 

it again on the confirmation pop-up screen. 

2.

 

Re-measure to verify the results are within 

tolerance. If they are not, repeat the 
Verti-Zontal

TM  

Correction Process (top of page 7).

Document the Results

1.

 

Press the file save icon. 

2.

 Press the white file name box to open the 

keypad. Enter a filename and then press the 
check mark.

3. 

Press the check mark again to save the file in 

My Measurements folder. You will see the saved 
image on screen for a few seconds, then return 
to the results screen. 

Summary of Contents for 100-EVO300

Page 1: ...Fixturlaser EVO Q U I C K T I P S 2017 VibrAlign Inc Fixturlaser EVO...

Page 2: ...and adjust the movable shaft to within 20 mils 0 020 of the stationary hub 2 Correct Obvious Soft Foot Loosen all the bolts and find any obviously loose shim packs Add shims as needed to make a snug...

Page 3: ...a Final Soft Foot Correction Loosen one bolt at a time and check for soft foot with a 2 mil 0 002 shim or feeler gauge Correct any foot with 2 mils or more of soft foot then tighten the bolt before pr...

Page 4: ...rizontal Alignment Program 1 From the main menu on the display unit touch the horizontal alignment icon 2 The lasers will turn on and the screen graphic will show the orientation of the sensors Aim th...

Page 5: ...dimension entry block Enter the indicated dimensions to the nearest 1 8 using the keypad 2 Touch the check mark to continue entering until all dimensions are entered 3 Select the RPM of the equipment...

Page 6: ...n being sure they move outside the red portion of the circle on the screen Press the measurement button again to take the second measurement 3 Rotate the sensors out of the red portion of the circle t...

Page 7: ...the Results 1 Vertical results are displayed at the top of the screen horizontal results at the bottom 2 Green coupling icons indicate values which are in tolerance 3 Orange values are within 2x tole...

Page 8: ...tion pop up screen 2 Loosen all the bolts on the movable machine 3 Follow screen instructions for removing or inserting shims Do not re tighten the bolts Next Correct the Horizontal Misalignment 1 Fir...

Page 9: ...indicate the direction of adjustment 5 Continue to adjust the movable machine watching the live readings until both the angle and offset are within tolerance 6 Tighten the bolts using the tightening...

Page 10: ...tolerance If they are not repeat the Verti ZontalTM Correction Process top of page 7 Document the Results 1 Press the file save icon 2 Press the white file name box to open the keypad Enter a filename...

Page 11: ...vibralign com VibrAlign Blog vibralign com blog The Alignment Store shaftalignment net Videos youtube com vibralign Free Alignment Apps vibralign com alignment tools apps Stay Connected Like Us on Fac...

Page 12: ...www vibralign com 800 379 2250 530 G Southlake Blvd Richmond VA 23236 Phone 800 379 2250 Fax 804 379 0189 2017 VibrAlign Inc Version 2 0 Fixturlaser EVO...

Reviews: