background image

 

14 



 [Pcs]  



 [%] 

Setup of units of 
measurement to 
be displayed 



 





  Unit not set 

  Disable 

Display of the 
auxiliary scale 
interval 

   



 

Enable (

  is the auxiliary scale interval.) 

Note:  The auxiliary-scale-interval place does not 

represent a verification scale interval. Use it 
only as a reference value. 

 

No output is made while the auxiliary scale interval is 
displayed. 

 

Output is made even while the auxiliary scale interval is 
displayed. 

Output format 
while the auxiliary 
scale interval is 
displayed 



 

Output is made with “/” added to the left of the 
auxiliary-scale-interval place. 

1 Setting is effective only when optional RS232C is used.   

2 Can be set only for a model on which the balance is not sealed. For a model on which the balance 

is sealed, only the units set when the balance was unsealed are effective.

1

〜☆

5: default 

factory settings [



]

[



]  

3 Not available in SJ-6200CE and SJ-12KCE.   

4 Applicable only in SJ-620CE & SJ-6200CE 

5 Displayed only in SJ-620CE & SJ-6200CE, when unsealed.   

 

4.3  Interface Section 

Displayed when [

   



   

] is set to [

] or [

Item Set 

Value 

Description 

Stop output 

Output continuous at all times 

Output continuous if stable (stop output if unstable) 

Outputs once by pressing    Memory    key (irrespective 
of whether stable). 

Outputs once if stable.    Outputs if the balance is stable 
when a sample is loaded after the preceding sample 
has been removed and the balance indicated zero, or 
less. 

Outputs once if stable, and stops output when unstable.   
Even if the sample is not replaced, the balance is output 
once when it stabilizes next time (including the zero 
indication). 

Outputs once if stable, and outputs continuously when 
unstable.    Even if the sample is not replaced, output of 
the balance stops when it stabilizes after being output 
once. 

Output Control 



 



Pressing    Memory    key causes the balance to output 
once when stable. 

1200 bps 

2400 bps 

4800 bps 

Baud Rate 



 



9600 bps 

None 

Odd 

Parity 



 



Even 

Displayed only when [

   



   

   

(7-digit numeric format)] is specified. 

  denotes a factory-setting   

 

  The data interval in continuous output mode is 0.1 to 1 second.    (The interval varies depending 

   on weighting conditions and other factors.) 

Summary of Contents for SJ-1200CE

Page 1: ...Balance SJ CE Series Operation Manual To ensure safe and proper use of the balance please read this manual carefully After reading this manual store it in a safe place near the balance so you can rev...

Page 2: ......

Page 3: ...keys Furthermore the large liquid crystal display provides excellent visibility and the instrument s high speed and stability intrinsic to a tuning fork design help boost operational efficiency Before...

Page 4: ...surement 15 6 Counting Pieces 17 6 1 Sampling 17 6 2 Increasing the Counting Accuracy Memory Update Method 19 7 Measuring Percentage 20 8 Limit Function 22 8 1 Limit Function Setup 22 8 2 Setup of Lim...

Page 5: ...ENDED This term indicates steps that the user should take to ensure the quality and reliability of the balance Meanings of Symbols Each symbol is accompanied by an instruction Mandatory Symbol Indicat...

Page 6: ...ric shock Keep Dry Do not use the balance in a location were it may be subjected to excess moisture Electric shock or short circuiting could occur The balance may be corroded with resultant malfunctio...

Page 7: ...increase in the balance may lead to inaccurate measurement Unplug Adapter If the balance is to be unused for an extended period of time unplug the adapter This conserves power and prevents deteriorati...

Page 8: ...g the level of the balance Turn the adjusters until the bubble rests in the center of the red circle Adjusters Round pan type Total of two one on either side of the unit s front Square pan type Total...

Page 9: ...hile span adjustment is in progress Auxiliary scale interval Lights up only when the auxiliary scale interval is displayed 1 Bar graph ct carat 3 oz ounce lb pound ozt troy ounce dwt penny weight tl t...

Page 10: ...mit function Function key Brief press toggle switches the units to be displayed in succession g Pcs etc Brief press moves the flashing digit in the setup of a limit value when using the value input me...

Page 11: ...in the level Turn the adjusters until the bubble rests in the center of the red circle on the level Caution Use caution when operating the adjusters on the square pan type to prevent them from liftin...

Page 12: ...mething is loaded the display does not change after In this case remove the load 3 Switching the measurement mode Press the Function key Each time the key is pressed the unit of measurement changes as...

Page 13: ...he weight of the sample loaded in the tare Weighing only the weight of an added sample 4 Resetting the indication to zero 0 0 F NET g Press the Zero Tare key The total weight of the sample loaded on t...

Page 14: ...er vibrations Use the windshield or vibration dampers to protect against such adverse effects Unstable Stable 0 F g 0 F g 4 When the read out indicator is reset to zero or the tare is subtracted the b...

Page 15: ...2 Selecting the next item Press the Function key The indication changes to the next item Limit function 3 Selecting an item Pressing the Function key advances the function items at the rate of one ite...

Page 16: ...imit values are set up judges among HI OK and LO Disable Auto zero zero tracking Enable This function automatically sets the zero point exactly to zero to prevent slight deviations Disable balance ope...

Page 17: ...200CE when unsealed 4 3 Interface Section Displayed when is set to or Item Set Value Description Stop output Output continuous at all times Output continuous if stable stop output if unstable Outputs...

Page 18: ...available in SJ 6200CE SJ 12KCE 5 2 Setup of Units of Measurement Only when the balance is not sealed When values to are entered prior to use the desired unit of measurement to be displayed can be cho...

Page 19: ...ed simply pressing the Function key For more information on the units of measurement that can be set please refer to 4 2 Description of Functions on page 13 2 The units are displayed in the same seque...

Page 20: ...Sample unit weight weight unit Sample weight Total g g 1 500 500 pcs Measured number of samples If samples to be counted deviate widely in weight or a higher measure of accuracy is desired it is reco...

Page 21: ...ollowing states 1 The weight of one sample measurable unit weight is insufficient For the range of unit weights that can be measured and saved please refer to 11 Specifications on page 30 2 In the sam...

Page 22: ...ples Pcs M Add approximately an equal number of samples as the number currently displayed Add them gradually in groups of approximately the same number until the number of samples is approximately dou...

Page 23: ...ce weight 1 Activating the percentage mode Press the Function key to disaplay 2 Setting the reference value Press the Set key The display begins flashing The balance is now ready for reference value s...

Page 24: ...The weight of the reference sample is insufficient For the limit weight that can be saved limit weight please refer to 11 Specifications on page 30 2 While setting up the reference value in Step 2 th...

Page 25: ...s the limit value 2 Numeric value setup method The limit value is entered with a key stroke The limit values entered are held in memory even when the balance is powered down The respective limit value...

Page 26: ...ion Press the Zero Tare key to select the desired condition 5 Setting the judgement range Judge entire range Judge beyond 5 Press the Function key The display changes to Judgement Range Press the Zero...

Page 27: ...emory key After the lower limit value has been saved the balance displays it briefly and proceeds to the following setup If One point setup was chosen the setup is complete 4 The upper limit value set...

Page 28: ...ess the Function key The flashing moves to the digit on the immediate left Each time the key is pressed the flashing digit moves one position left When the leftmost digit is selected the flashing adva...

Page 29: ...imit value displayed Measurement mode restored Continuous pressing g M g M g 2 If you make a mistake press the Function key during the setup of actual quantities or the Set key during the setup of val...

Page 30: ...ent should be performed with the balance installed perfectly level and without any load on the measurement pan 1 Activating the span adjustment function Pressed continuously Key released Press and hol...

Page 31: ...ity of the balance To implement a calibration as precisely as possible use a weight close to the capacity of the balance Calibration weights can be ordered from Shinko For ordering information please...

Page 32: ...rent when the power is switched on Overcharging will also decrease battery life 2 When the balance is used for the first time after purchase the operating time may be shorter than when using a fully c...

Page 33: ...insufficient Execute the Memory Update Method 19 appears before the capacity is reached Gross weight exceeded the capacity of the balance weight range container weight of sample A section of the mech...

Page 34: ...40 180 160 12 2 Common Specifications 1 Weight measuring method Tuning fork vibration method 2 Tare subtraction range Total capacity 3 Liquid crystal display LCD Seven segments two segments in leading...

Page 35: ...01 7 13 19 38 70 130 190 380 troy ounce ozt 0 001 0 001 0 001 0 01 0 01 0 01 0 01 0 01 140 270 390 770 1400 2700 3900 7700 penny weight dwt 0 01 0 01 0 01 0 1 0 1 0 1 0 1 0 1 5 8 11 16 32 58 110 160 3...

Page 36: ...aiwan 37 5 187 5 1 32277 0 08267 1 20565 24 11306 1mom 3 75 18 75 0 13228 0 00827 0 12057 2 41131 1to 11 66380 58 31902 0 41143 0 02571 0 37500 7 5 unit tael Hong Kong tael Singapore Malaysia tael Tai...

Reviews: