3. Service Manual
3.1. Control panel
– technical information:
Set point setting (desired temperature value)
The easy, easy compact and easy split devices control the desired temperature (set point) inside the cabinet
or cold room directly and dynamically.
To view and modify the set point:
- press SET for 1s, the set value will start flashing;
- increase or decrease the value using UP or DOWN;
- press SET to confirm the new value.
Manual defrost
Not available on the easy thermometer (M) and easy compact models. Press DOWN for more than 3s
(activated only if the temperature conditions are right , for easy split only if the light output is not set,
H1=4). Alternatively, on easy split models, if the light output is set (H1=4), the defrost can be activated by
pressing UP and DOWN together, when (H6=1).