34
OLP-39G/-39X TruePON Tester
11 S
PECIFICATIONS
OLP-39G/-39X
11
S
PECIFICATIONS
OLP-39G/-39X
G-PON (1490 nm downstream)
XGS-PON (1577 nm downstream, OLP-39X only)
General specifications
Memory
Calibration
interval
Measurement range for power level
-35 to +10 dBm
Measurement Range for PON-ID
-30 to 0 dBm
Maximum power level
+20 dBm continuously
+26 dBm <30 min.
Spectral range
1480 to 1500 nm
Measurement uncertainty
±0.5 dBm
1)
1) At -10 dBm, at 23 °C ± 3 °C, at nominal wavelength
Measurement range for power level
-35 to +10 dBm
Measurement Range for PON-ID
-25 to 0 dBm
Maximum power level
+20 dBm continuously
+26 dBm <30 min.
Spectral range
1575 to 1580 nm
Measurement uncertainty
±0.5 dBm
1)
1) At -10 dBm, at 23 °C ± 3 °C, at nominal wavelength
Number of calibrated wavelengths
2 (1490 nm, 1577 nm)
Optical adapter system
Fixed SC
Data storage
1000 results
Data download capability
USB-C for PC transfer
Recommended calibration interval
3 years