background image

DSP TDR

Quick Start Guide

Summary of Contents for DSP TDR

Page 1: ...DSP TDR Quick Start Guide ...

Page 2: ...Number printed The catalog number for an electronic guide on USB is Catalog Number electronic Terms and conditions Specifications terms and conditions are subject to change without notice The provision of hardware services and or software are subject to VIAVI standard terms and conditions available at www viavisolutions com en terms and conditions Federal Communications Commission FCC Notice This ...

Page 3: ... WEEE Program Management team at WEEE EMEA ViaviSolutions com EU REACH Article 33 of EU REACH regulation EC No 1907 2006 requires article suppliers to provide information if a listed Substance of Very High Concern SVHC is present in an article above a certain threshold For information on the presence of REACH SVHCs in VIAVI products see the Hazardous Substance Control section of the VIAVI Standard...

Page 4: ... the dialog box Variables Type the new hostname Book references Refer to Newton s Telecom Dictionary A vertical bar means or only one option can appear in a single command platform a b e Square brackets indicate an optional argument login platform name Slanted brackets group required arguments password Description Example A plus sign indicates simultaneous keystrokes Press Ctrl s A comma indicates...

Page 5: ...LERT message See Safety Definitions on page vi for more information This symbol represents a risk of explosion It may be associated with either a DANGER WARNING CAUTION or ALERT message See Safety Definitions on page vi for more information This symbol represents a risk of a hot surface It may be associated with either a DANGER WARNING CAUTION or ALERT message See Safety Definitions on page vi for...

Page 6: ... be associated with either a general hazard high voltage or other symbol CAUTION Indicates a potentially hazardous situation that if not avoided could result in minor or moderate injury and or damage to equipment It may be associated with either a general hazard high voltage or risk of explosion symbol When applied to software actions indicates a situation that if not avoided could result in loss ...

Page 7: ...is installed at the VIAVI factory or by VIAVI approved repair facilities During operation of the device a distance of 20 cm or more should be maintained between the antenna in this device and person To ensure compliance do not operate at closer distances than this The antenna on the unit is located inside the device at the top of the unit attached to the back plastic case Do not use any antenna ot...

Page 8: ...to wipe the screen If you do these non ultrasoft materials can cause permanent damage by scratching the screen or stripping the anti glare coating off the screen NOTE Never use any type of window cleaner soap scouring powder or any cleanser with solvents such as alcohol benzene ammonia or paint thinner These chemicals can react with the materials used to construct the display which can lead to haz...

Page 9: ...ovides setup and operating instructions to get you up and running as soon as possible Technical Assistance If you require technical assistance call 1 844 GO VIAVI 1 844 468 4284 Outside US 1 855 275 5378 Email Trilithic support viavisolutions com For the latest TAC information visit https support viavisolutions com welcome ...

Page 10: ...ep technology which enables it to show smaller faults has no blind spot and maintains accuracy for detecting impedance over the entire length of the cable Automatic impedance matching allows for faster trace results without pulse width adjustments In addition to the ability to find faults closer to the TDR no blind spot the TDR has a resolution of less than 1 foot 0 3m The higher energy step TDR h...

Page 11: ...000 July 2019 3 Touchscreen LCD Softkeys Back Button Arrow Buttons Power Button Enter Button User 2 Button Water Resistant Speaker TDR Connector User 1 Button Battery Status Indicators Function Button Front View A Guided tour of the DSP TDR ...

Page 12: ...er door is in the open position for illustrative purposes This door should remain closed when not using any of these ports Bottom view Ethernet Port 10 100 Mbit s USB 2 0 Port Type A DC Charge Port System Reset Button Protective Rubber Door with Magnetic Closure Internal Wi Fi Antenna 2 dB Gain TDR Connector ...

Page 13: ...DSP TDR Quick Start Guide 22134505 Rev 000 July 2019 5 Rear view Internal Wi Fi Antenna 2 dB Gain Identification Label S N FCC ID Notice TDR Connector DSP TDR DSP TDR ...

Page 14: ...ely 0 of battery capacity When the battery charge drops to this level it is recommended that the battery is charged immediately On Screen charging status The Title Bar at the top of the screen displays the battery voltage and the following charging status icons Battery status Three Battery Status Indicators are located on the front panel These indicators represent the status of each of the three i...

Page 15: ...ate using the left and right arrows to the VoP field and press Enter A pop up keyboard will allow you to select the desired value for the cable type being tested Preset VoPs are available for selection from the yellow soft keys at the bottom of the screen 6 Enter the VoP value and select the Done softkey 7 Navigate using the left right arrows to the Read Dist field Use the up down arrows to change...

Page 16: ...distance Sets the viewing distance at the right edge of screen Purple marker Movable marker that can be placed at user defined distance Blue marker Movable marker that can be placed at user defined distance Marker moves to event location when selecting an event from the event list Trace Live or single trace Function menu Screen Capture Stores a PNG file of current screen display Save Data Log Stor...

Page 17: ...ctions Displaying the events list 1 While viewing results select the Function button to bring up the Function menu 2 Navigate to Show Events List using the up down arrows and press Enter 3 A pop up screen will show the list of events distances and measurements When you select an event the marker moves to the event location Saving results Screen Capture 1 While viewing results select the Function b...

Page 18: ...ored file will save and can be uploaded to StrataSync Uploading results to StrataSync 1 Prior to attempting data upload ensure that the Tech number StrataSync account ID and URL are entered in the Setup Config User menu 2 From any main menu select the Function button to connect to the network 3 From the pop up menu navigate up or down to Network Manager and select Enter 4 Navigate using the arrow ...

Page 19: ...layed To connect via Wi Fi 1 From the Wi Fi settings pop up window wait for the access point list to populate 2 Using the up down arrows navigate the list of SSIDs to the preferred access point 3 Use the right left arrows to highlight the current password and select Enter 4 Use the virtual keyboard to enter the password 5 Once the password is entered select the Done softkey 6 Navigate to the Curre...

Page 20: ...e job to close and select Close A pop up will ask you to confirm Select OK to close A virtual keyboard will appear so that comments can be added Type comments up to 32 characters and select Done Select Cancel to cancel To delete a job highlight the job to delete and select Delete from the yellow soft keys A pop up will ask you to confirm Select OK to delete Select Cancel to cancel To change commen...

Page 21: ...eral tab Displays the package firmware version Network tab Displays the MAC IDs for CPE and Wi Fi Memory tab Displays available and used memory Options tab Displays the installed options Config Global Settings for time date language and operating level normal cal logging User Settings for username company tech ID StrataSync account ID and StrataSync URL Interface User comfort settings like distanc...

Page 22: ...ta Cal Touch Used to calibrate touch screen Update FW Used to update firmware via web or USB Limited Warranty For the latest warranty information visit https www viavisolutions com literature viavi solutions inc general terms en pdf https www viavisolutions com en us literature viavi manufacturer warranty nse products en pdf ...

Page 23: ...xels approx 4 5 x 2 75 Annunciators Audible annunciator for key strokes Dimensions w o Case H x W x D 8 6 x 6 1 x 2 00 in 21 84 x 15 94 x 5 08 cm Dimensions w Case H x W x D 9 6 x 7 1 x 3 00 in 24 38 x 18 03 x 7 62 cm Weight w o Case 3 75 lbs 1 70 Kg Weight w Case 4 75 lbs 2 15 Kg Interface Types TDR Test Port 75 Ohm Replaceable F Type Connector Ethernet RJ45 10 100 Mbps WiFi 802 11 b g n 2 4 5 GH...

Page 24: ...ica 1 844 GO VIAVI 1 844 468 4284 Latin America 52 55 5543 6644 EMEA 49 7121 862273 APAC 1 512 201 6534 All Other Regions viavisolutions com contacts email Trilithic support viavisolutions com 22134505 Rev 000 July 2019 English ...

Reviews: